Evaluation of RF interactions between a 3T birdcage transmit coil and transcranial magnetic stimulation coils using a realistically shaped head phantom. Issue 2 (23rd January 2020)
- Record Type:
- Journal Article
- Title:
- Evaluation of RF interactions between a 3T birdcage transmit coil and transcranial magnetic stimulation coils using a realistically shaped head phantom. Issue 2 (23rd January 2020)
- Main Title:
- Evaluation of RF interactions between a 3T birdcage transmit coil and transcranial magnetic stimulation coils using a realistically shaped head phantom
- Authors:
- Navarro de Lara, Lucia I.
Golestanirad, Laleh
Makarov, Sergey N.
Stockmann, Jason P.
Wald, Lawrence L.
Nummenmaa, Aapo - Abstract:
- Abstract : Purpose: Multichannel transcranial magnetic stimulation (TMS) 1 is an emerging technology that allows multiple sites to be stimulated simultaneously or sequentially under electronic control without movement of the coils. A multichannel TMS/MRI head coil array for 3 Tesla is currently under development to mitigate challenges of concurrent TMS/fMRI as well as enable potential new applications. The influence of the multichannel TMS system on the MR image quality and safety must be carefully investigated. Methods: A standard birdcage volume coil for 3 Tesla systems was simulated using a commercial numerical electromagnetic solver. Two setups, consisting of 1) a MR‐compatible TMS coil, and 2) a 3‐axis TMS coil array, were simulated to quantify changes in the transmit field B 1 + and the SAR. A realistically shaped homogeneous head model was used in the computations. Results: The stimulation coils produced enhancements and attenuations on the transmit field with effects greater than 5% up to 2.4 cm and 3.3 cm under the scalp for the MR‐compatible TMS coil and 3‐axis TMS coil array, respectively. The 10 g‐SAR distribution did not change significantly in either of the cases; however, the nominal SAR maximum locus was shifted between existing hot spots. Conclusion: The simulated B 1 + variations found near the TMS coils indicate the possibility of inducing sequence‐dependent image artefacts predominatly limited to the vicinity of the coil(s). However, we conclude thatAbstract : Purpose: Multichannel transcranial magnetic stimulation (TMS) 1 is an emerging technology that allows multiple sites to be stimulated simultaneously or sequentially under electronic control without movement of the coils. A multichannel TMS/MRI head coil array for 3 Tesla is currently under development to mitigate challenges of concurrent TMS/fMRI as well as enable potential new applications. The influence of the multichannel TMS system on the MR image quality and safety must be carefully investigated. Methods: A standard birdcage volume coil for 3 Tesla systems was simulated using a commercial numerical electromagnetic solver. Two setups, consisting of 1) a MR‐compatible TMS coil, and 2) a 3‐axis TMS coil array, were simulated to quantify changes in the transmit field B 1 + and the SAR. A realistically shaped homogeneous head model was used in the computations. Results: The stimulation coils produced enhancements and attenuations on the transmit field with effects greater than 5% up to 2.4 cm and 3.3 cm under the scalp for the MR‐compatible TMS coil and 3‐axis TMS coil array, respectively. The 10 g‐SAR distribution did not change significantly in either of the cases; however, the nominal SAR maximum locus was shifted between existing hot spots. Conclusion: The simulated B 1 + variations found near the TMS coils indicate the possibility of inducing sequence‐dependent image artefacts predominatly limited to the vicinity of the coil(s). However, we conclude that neither the MR‐compatible commercial TMS coil nor the 3‐axis TMS coil array siginificantly elevate SAR in the head or neck beyond accepted safety limits. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 84:Issue 2(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 84:Issue 2(2020)
- Issue Display:
- Volume 84, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 84
- Issue:
- 2
- Issue Sort Value:
- 2020-0084-0002-0000
- Page Start:
- 1061
- Page End:
- 1075
- Publication Date:
- 2020-01-23
- Subjects:
- B1+ -- birdcage coil -- fMRI -- multichannel TMS -- SAR -- TMS
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28162 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18710.xml