Clindamycin-loaded titanium prevents implant-related infection through blocking biofilm formation. (February 2022)
- Record Type:
- Journal Article
- Title:
- Clindamycin-loaded titanium prevents implant-related infection through blocking biofilm formation. (February 2022)
- Main Title:
- Clindamycin-loaded titanium prevents implant-related infection through blocking biofilm formation
- Authors:
- Li, Youbin
Wang, Shaochuan
Li, Shidan
Fei, Jun - Abstract:
- Implant-related infection is a disastrous complication. Surface modification of titanium is considered as an important strategy to prevent implant-related infection. However, there is no recognized surface modification strategy that can be applied in clinic so far. We explored a new strategy of coating. The clindamycin-loaded titanium was constructed by layer-by-layer self-assembly. The release of clindamycin from titanium was detected through high performance liquid chromatography. Different titanium was co-cultured with Staphylococcus aureus for 24 h in vitro, then the effect of different titanium on bacterial colonization and biofilm formation was determined by spread plate method and scanning electron microscopy. Cytotoxicity and cytocompatibility of clindamycin-loaded titanium on MC3T3-E1 cells were measured by CCK8. The antibacterial ability of clindamycin-loaded titanium in vivo was also evaluated using a rat model of osteomyelitis. The number of osteoclasts in bone defect was observed by tartrate-resistant acid phosphatase staining. Bacterial burden of surrounding tissues around the site of infection was calculated by tissue homogenate and colony count. Clindamycin-loaded titanium could release clindamycin slowly within 160 h. It reduced bacterial colonization by three orders of magnitude compare to control ( p < .05) and inhibits biofilm formation in vitro. Cells proliferation and adhesion were similar on three titanium surfaces ( p > .05). In vivo,Implant-related infection is a disastrous complication. Surface modification of titanium is considered as an important strategy to prevent implant-related infection. However, there is no recognized surface modification strategy that can be applied in clinic so far. We explored a new strategy of coating. The clindamycin-loaded titanium was constructed by layer-by-layer self-assembly. The release of clindamycin from titanium was detected through high performance liquid chromatography. Different titanium was co-cultured with Staphylococcus aureus for 24 h in vitro, then the effect of different titanium on bacterial colonization and biofilm formation was determined by spread plate method and scanning electron microscopy. Cytotoxicity and cytocompatibility of clindamycin-loaded titanium on MC3T3-E1 cells were measured by CCK8. The antibacterial ability of clindamycin-loaded titanium in vivo was also evaluated using a rat model of osteomyelitis. The number of osteoclasts in bone defect was observed by tartrate-resistant acid phosphatase staining. Bacterial burden of surrounding tissues around the site of infection was calculated by tissue homogenate and colony count. Clindamycin-loaded titanium could release clindamycin slowly within 160 h. It reduced bacterial colonization by three orders of magnitude compare to control ( p < .05) and inhibits biofilm formation in vitro. Cells proliferation and adhesion were similar on three titanium surfaces ( p > .05). In vivo, clindamycin-loaded titanium improved bone healing, reduced microbial burden, and decreased the number of osteoclasts compared control titanium in the rat model of osteomyelitis. This study demonstrated that clindamycin-loaded titanium exhibited good biocompatibility, and showed antibacterial activity both in vivo and in vitro. It is promising and might have potential for clinical application. … (more)
- Is Part Of:
- Journal of biomaterials applications. Volume 36:Number 7(2022)
- Journal:
- Journal of biomaterials applications
- Issue:
- Volume 36:Number 7(2022)
- Issue Display:
- Volume 36, Issue 7 (2022)
- Year:
- 2022
- Volume:
- 36
- Issue:
- 7
- Issue Sort Value:
- 2022-0036-0007-0000
- Page Start:
- 1231
- Page End:
- 1242
- Publication Date:
- 2022-02
- Subjects:
- Clindamycin -- implant-related infection -- staphylococcus aureus -- coating -- titanium
Biomedical engineering -- Periodicals
Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://jba.sagepub.com ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/08853282211051183 ↗
- Languages: