Transcatheter aortic valve implantation in patients with small aortic annuli using a 20 mm balloon-expanding valve. Issue 2 (17th August 2016)
- Record Type:
- Journal Article
- Title:
- Transcatheter aortic valve implantation in patients with small aortic annuli using a 20 mm balloon-expanding valve. Issue 2 (17th August 2016)
- Main Title:
- Transcatheter aortic valve implantation in patients with small aortic annuli using a 20 mm balloon-expanding valve
- Authors:
- Puri, Rishi
Byrne, Jonathan
Muller, Ralf
Baumbach, Hardy
Eltchaninoff, Helene
Redwood, Simon
Cheema, Asim
Dubois, Christophe
Ihlberg, Leo
Wijeysundera, Harindra C
Cerillo, Alfredo
Götberg, Matthias
Klaaborg, Kaj Erik
Pelletier, Marc
Blanco-Mata, Roberto
Edwards, Richard
Gandolfo, Caterina
Muir, Douglas
Meucci, Francesco
Sinning, Jan-Malte
Stella, Pieter
Veulemans, Verena
Virtanen, Marko
Regueiro, Ander
Thoenes, Martin
Pibarot, Philippe
Pelletier-Beaumont, Emilie
Rodés-Cabau, Josep - Abstract:
- Abstract : Background: While transcatheter aortic valve implantation (TAVI) is established for treating high-operative risk surgical aortic valve replacement candidates, until recently the smallest transcatheter heart valve (THV) measured 23 mm, posing greater risk for annular rupture and THV failure in patients with aortic stenosis (AS) with small aortic annuli (≤20 mm). Objectives: In the setting of a multicentre registry, we report on the safety, efficacy and early clinical outcomes of the SAPIEN XT 20 mm balloon-expanding THV. Results: Among TAVI 55 recipients (n=30 for native AS, n=25 for a valve-in-valve procedure (V-in-V)), median age and Society of Thoracic Surgeons score were 85 (81 to 87) years and 7.8 (4.7 to 12.4)%, respectively. Mean and minimum annular diameters were 19±1 and 17±2 mm, respectively, in native patients with AS, and 17±1 mm (internal diameter) in V-in-V recipients. Successful device implantation rate was 96%, with no procedural-related death. Overall in-hospital-30-day death, stroke and major bleeding rates were 5%, 2% and 9%, respectively. In native AS TAVI recipients, mean transaortic gradient decreased from 54±20 to 12±5 mm Hg (p<0.001), and from 45±17 to 24±8 mm Hg (p<0.001) in V-in-V recipients. Severe prosthesis-patient mismatch (PPM) rates were 10% and 48% in native AS and V-in-V TAVI recipients, respectively (p=0.03). Post-TAVI, the rate of moderate aortic regurgitation was 7% and 0% in native AS and V-in-V TAVI recipients, respectively.Abstract : Background: While transcatheter aortic valve implantation (TAVI) is established for treating high-operative risk surgical aortic valve replacement candidates, until recently the smallest transcatheter heart valve (THV) measured 23 mm, posing greater risk for annular rupture and THV failure in patients with aortic stenosis (AS) with small aortic annuli (≤20 mm). Objectives: In the setting of a multicentre registry, we report on the safety, efficacy and early clinical outcomes of the SAPIEN XT 20 mm balloon-expanding THV. Results: Among TAVI 55 recipients (n=30 for native AS, n=25 for a valve-in-valve procedure (V-in-V)), median age and Society of Thoracic Surgeons score were 85 (81 to 87) years and 7.8 (4.7 to 12.4)%, respectively. Mean and minimum annular diameters were 19±1 and 17±2 mm, respectively, in native patients with AS, and 17±1 mm (internal diameter) in V-in-V recipients. Successful device implantation rate was 96%, with no procedural-related death. Overall in-hospital-30-day death, stroke and major bleeding rates were 5%, 2% and 9%, respectively. In native AS TAVI recipients, mean transaortic gradient decreased from 54±20 to 12±5 mm Hg (p<0.001), and from 45±17 to 24±8 mm Hg (p<0.001) in V-in-V recipients. Severe prosthesis-patient mismatch (PPM) rates were 10% and 48% in native AS and V-in-V TAVI recipients, respectively (p=0.03). Post-TAVI, the rate of moderate aortic regurgitation was 7% and 0% in native AS and V-in-V TAVI recipients, respectively. Conclusions: TAVI with the 20 mm SAPIEN XT THV appears safe and technically feasible, with acceptable short-term clinical outcomes and low rates of severe PPM in those with native AS. … (more)
- Is Part Of:
- Heart. Volume 103:Issue 2(2017)
- Journal:
- Heart
- Issue:
- Volume 103:Issue 2(2017)
- Issue Display:
- Volume 103, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 103
- Issue:
- 2
- Issue Sort Value:
- 2017-0103-0002-0000
- Page Start:
- 148
- Page End:
- 153
- Publication Date:
- 2016-08-17
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2016-309707 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18649.xml