NB-SQI: A novel non-binary signal quality index for continuous blood pressure waveforms. (September 2021)
- Record Type:
- Journal Article
- Title:
- NB-SQI: A novel non-binary signal quality index for continuous blood pressure waveforms. (September 2021)
- Main Title:
- NB-SQI: A novel non-binary signal quality index for continuous blood pressure waveforms
- Authors:
- Ignácz, Anna
Földi, Sándor
Sótonyi, Péter
Cserey, György - Abstract:
- Abstract: Continuous blood pressure monitoring has utmost importance in healthcare, but is usually realised by invasive arterial cannulation. Non-invasive solutions are starting to become a viable option, but these solutions are more sensitive to sensor placement and patient movement. To support these non-invasive monitoring devices, a continuous signal quality feedback would be advantageous. The aim of this study is to define a non-binary signal quality index (NB-SQI) for continuous blood pressure waveforms that can be used for monitoring devices. The definition of this NB-SQI is based on features derived from the continuous waveform of the cardiac cycle and it tests the abnormality of the signal and measures the normalised deviation of its characteristics from an expected value. The method was validated with a dataset of 20 signals, each 10 s long, and labelled by senior specialists in the field of vascular surgery and anesthesiology. The NB-SQI showed a 0.95 correlation with the labels of the validation set. The tendency of the NB-SQI was tested on generated and measured signals corrupted by generated noises on different levels. The results showed that the NB-SQI gives a quantitative estimation in the higher quality range, and recognises the abnormal and noise corrupted segments. The defined NB-SQI can have a significant contribution to the development of non-invasive continuous blood pressure monitors, but it can also be used in signal processing or signal classificationAbstract: Continuous blood pressure monitoring has utmost importance in healthcare, but is usually realised by invasive arterial cannulation. Non-invasive solutions are starting to become a viable option, but these solutions are more sensitive to sensor placement and patient movement. To support these non-invasive monitoring devices, a continuous signal quality feedback would be advantageous. The aim of this study is to define a non-binary signal quality index (NB-SQI) for continuous blood pressure waveforms that can be used for monitoring devices. The definition of this NB-SQI is based on features derived from the continuous waveform of the cardiac cycle and it tests the abnormality of the signal and measures the normalised deviation of its characteristics from an expected value. The method was validated with a dataset of 20 signals, each 10 s long, and labelled by senior specialists in the field of vascular surgery and anesthesiology. The NB-SQI showed a 0.95 correlation with the labels of the validation set. The tendency of the NB-SQI was tested on generated and measured signals corrupted by generated noises on different levels. The results showed that the NB-SQI gives a quantitative estimation in the higher quality range, and recognises the abnormal and noise corrupted segments. The defined NB-SQI can have a significant contribution to the development of non-invasive continuous blood pressure monitors, but it can also be used in signal processing or signal classification for diagnostic purposes. Highlights: Signal quality has great importance in biomedical signal recording. NB-SQI: A novel non-binary signal quality index for blood pressure waveforms. NB-SQI can be defined using the features of blood pressure waveforms. NB-SQI shows high correlation with the opinion of professionals. NB-SQI can be a great tool for invasive and non-invasive blood pressure monitors. Development of automated sensor placement can also be supported by NB-SQI. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 70(2021)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 70(2021)
- Issue Display:
- Volume 70, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 70
- Issue:
- 2021
- Issue Sort Value:
- 2021-0070-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-09
- Subjects:
- Continuous blood pressure -- Signal quality index -- Signal processing
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2021.103035 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18633.xml