Applying a dual-Scheimpflug camera to measure tear film thickness. Issue 1 (January 2022)
- Record Type:
- Journal Article
- Title:
- Applying a dual-Scheimpflug camera to measure tear film thickness. Issue 1 (January 2022)
- Main Title:
- Applying a dual-Scheimpflug camera to measure tear film thickness
- Authors:
- Keren, Shay
Mimouni, Michael
McCallum, Ewan
Rabina, Gilad
Levinger, Eliya - Abstract:
- Purpose: To assess the tear film thickness in healthy individuals by using a dual-Scheimpflug camera and topical 0.1% fluorescein. Methods: A prospective study on healthy individuals who underwent a bilateral tomography examination using the GALILEI dual-Scheimpflug with assessments of the thinnest and central corneal thickness (TCT and CCT, respectively), at baseline and 1 min after applying 2 and 4 µl of 0.1% fluorescein (30 min apart) under topical anesthesia with Oxybuprocaine 0.4%. Inclusion criteria were lack of dry eye disease symptoms and exclusion criteria were contact lens usage, eye drops usage, previous refractive surgery or any ocular surgery. All individuals scored zero on the ocular surface disease index (OSDI) questionnaire. Results: A total of 62 eyes of 31 participants were included in this study. The mean age was 35.3 ± 10.88 (range 18–62). The mean TCT in was 549.16 µm in the right eye (RE) and 547.84 µm in the left eye (LE). After instillation of 2 µl of 0.1% fluorescein mean TCT increase by 27.84 µm in the RE and by 26.35 µm in the LE. CCT change was 27.58 µm increase in RE and 27.23 µm increase in LE. After instillation of 4 µl of 0.1% fluorescein the mean increase in TCT and CCT were 30.09 and 30.26 µm for OD and 28.33 and 30.15 µm for OS respectively. Comparison between the post instillation of 2 and 4 µl measurements showed no significant differences. Conclusion: Combining a dual-Scheimpflug camera and 0.1% fluorescein may serve as a method toPurpose: To assess the tear film thickness in healthy individuals by using a dual-Scheimpflug camera and topical 0.1% fluorescein. Methods: A prospective study on healthy individuals who underwent a bilateral tomography examination using the GALILEI dual-Scheimpflug with assessments of the thinnest and central corneal thickness (TCT and CCT, respectively), at baseline and 1 min after applying 2 and 4 µl of 0.1% fluorescein (30 min apart) under topical anesthesia with Oxybuprocaine 0.4%. Inclusion criteria were lack of dry eye disease symptoms and exclusion criteria were contact lens usage, eye drops usage, previous refractive surgery or any ocular surgery. All individuals scored zero on the ocular surface disease index (OSDI) questionnaire. Results: A total of 62 eyes of 31 participants were included in this study. The mean age was 35.3 ± 10.88 (range 18–62). The mean TCT in was 549.16 µm in the right eye (RE) and 547.84 µm in the left eye (LE). After instillation of 2 µl of 0.1% fluorescein mean TCT increase by 27.84 µm in the RE and by 26.35 µm in the LE. CCT change was 27.58 µm increase in RE and 27.23 µm increase in LE. After instillation of 4 µl of 0.1% fluorescein the mean increase in TCT and CCT were 30.09 and 30.26 µm for OD and 28.33 and 30.15 µm for OS respectively. Comparison between the post instillation of 2 and 4 µl measurements showed no significant differences. Conclusion: Combining a dual-Scheimpflug camera and 0.1% fluorescein may serve as a method to assess the pre-corneal tear film. … (more)
- Is Part Of:
- European journal of ophthalmology. Volume 32:Issue 1(2022)
- Journal:
- European journal of ophthalmology
- Issue:
- Volume 32:Issue 1(2022)
- Issue Display:
- Volume 32, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 32
- Issue:
- 1
- Issue Sort Value:
- 2022-0032-0001-0000
- Page Start:
- 160
- Page End:
- 164
- Publication Date:
- 2022-01
- Subjects:
- Topography -- dry eye -- corneal thickness -- tear film
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
617.7005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://www.eur-j-ophthalmol.com/Home/Index ↗
http://journals.sagepub.com/home/ejo ↗ - DOI:
- 10.1177/11206721211000274 ↗
- Languages:
- English
- ISSNs:
- 1120-6721
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18648.xml