A study of the accuracy of the Fitbit Zip in measuring steps both indoors and outdoors in a mixed rehabilitation population. (January 2022)
- Record Type:
- Journal Article
- Title:
- A study of the accuracy of the Fitbit Zip in measuring steps both indoors and outdoors in a mixed rehabilitation population. (January 2022)
- Main Title:
- A study of the accuracy of the Fitbit Zip in measuring steps both indoors and outdoors in a mixed rehabilitation population
- Authors:
- Farmer, Craig
van den Berg, Maayken EL
Vuu, Sally
Barr, Christopher J - Abstract:
- Objective: To assess (1) step count accuracy of the Fitbit Zip, compared to manual step count, in people receiving outpatient rehabilitation, in indoor and outdoor conditions, and (2) impact of slow walking speed on Fitbit accuracy. Design: Observational study. Setting: A metropolitan rehabilitation hospital. Subjects: Adults ( n = 88) attending a subacute rehabilitation outpatient clinic with walking speeds of between 0.4 and 1.0 m/s. Interventions: Two 2-minute walk tests, one indoors and one outdoors, completed in random order. Main measures: Step count recorded manually by observation and by a Fitbit Zip, attached to the shoe on the dominant or non-affected side. Subgroup analysis included assessment accuracy for those considered limited community walkers (slower than 0.8 m/s) and those considered community walkers (faster than 0.8 m/s). Results: The Fitbit significantly ( P < 0.05) undercounted steps compared to manual step count, indoors and outdoors, with percentage agreement slightly higher outdoors (mean 92.4%) than indoors (90.1%). Overall, there was excellent consistent agreement between the Fitbit and manual step count for both indoor (ICC 0.83) and outdoor (ICC 0.88) walks. The accuracy of the Fitbit was significantly ( P < 0.05) reduced in those who walked slower than 0.8 m/s outdoors (ICC 0.80) compared to those who walk faster than 0.8 m/s (ICC 0.90). Conclusions: The Fitbit Zip shows high step count accuracy with manual step count in a mixed subacuteObjective: To assess (1) step count accuracy of the Fitbit Zip, compared to manual step count, in people receiving outpatient rehabilitation, in indoor and outdoor conditions, and (2) impact of slow walking speed on Fitbit accuracy. Design: Observational study. Setting: A metropolitan rehabilitation hospital. Subjects: Adults ( n = 88) attending a subacute rehabilitation outpatient clinic with walking speeds of between 0.4 and 1.0 m/s. Interventions: Two 2-minute walk tests, one indoors and one outdoors, completed in random order. Main measures: Step count recorded manually by observation and by a Fitbit Zip, attached to the shoe on the dominant or non-affected side. Subgroup analysis included assessment accuracy for those considered limited community walkers (slower than 0.8 m/s) and those considered community walkers (faster than 0.8 m/s). Results: The Fitbit significantly ( P < 0.05) undercounted steps compared to manual step count, indoors and outdoors, with percentage agreement slightly higher outdoors (mean 92.4%) than indoors (90.1%). Overall, there was excellent consistent agreement between the Fitbit and manual step count for both indoor (ICC 0.83) and outdoor (ICC 0.88) walks. The accuracy of the Fitbit was significantly ( P < 0.05) reduced in those who walked slower than 0.8 m/s outdoors (ICC 0.80) compared to those who walk faster than 0.8 m/s (ICC 0.90). Conclusions: The Fitbit Zip shows high step count accuracy with manual step count in a mixed subacute rehabilitation population. However, accuracy is affected by walking speed, with decreased accuracy in limited community walkers. … (more)
- Is Part Of:
- Clinical rehabilitation. Volume 36:Number 1(2022)
- Journal:
- Clinical rehabilitation
- Issue:
- Volume 36:Number 1(2022)
- Issue Display:
- Volume 36, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 36
- Issue:
- 1
- Issue Sort Value:
- 2022-0036-0001-0000
- Page Start:
- 125
- Page End:
- 132
- Publication Date:
- 2022-01
- Subjects:
- Mobility -- rehabilitation -- walking -- step activity monitor
Medical rehabilitation -- Periodicals
617.03 - Journal URLs:
- http://cre.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/02692155211035293 ↗
- Languages:
- English
- ISSNs:
- 0269-2155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18639.xml