Comparative studies with EPR and MRI on the in vivo tissue redox status estimation using redox-sensitive nitroxyl probes: influence of the choice of the region of interest. (1st February 2018)
- Record Type:
- Journal Article
- Title:
- Comparative studies with EPR and MRI on the in vivo tissue redox status estimation using redox-sensitive nitroxyl probes: influence of the choice of the region of interest. (1st February 2018)
- Main Title:
- Comparative studies with EPR and MRI on the in vivo tissue redox status estimation using redox-sensitive nitroxyl probes: influence of the choice of the region of interest
- Authors:
- Matsumoto, Ken-ichiro
Mitchell, James B.
Krishna, Murali C. - Abstract:
- Abstract: In vivo decay rates of a nitroxyl contrast agent were estimated by a MR redox imaging (MRRI) technique and compared with the decay rates obtained by the electron paramagnetic resonance spectroscopy (EPRS) and imaging (EPRI). MRRI is a dynamic imaging technique employing T1 -weighted pulse sequence, which can visualise a nitroxyl-induced enhancement of signal intensity by T1 -weighted contrast. EPR techniques can directly measure the paramagnetic nitroxyl radical. Both the squamous cell carcinoma (SCC) tumour-bearing and normal legs of a female C3H mouse were scanned by T1 -weighted SPGR sequence at 4.7 T with the nitroxyl radical, carbamoyl-proxyl (CmP), as the contrast agent. Similarly, the time course of CmP in normal muscle and tumour tissues was obtained using a 700-MHz EPR spectrometer with a surface coil. The time course imaging of CmP was also performed by 300 MHz CW EPR imager. EPRS and EPRI gave slower decay rates of CmP compared to the MRRI. Relatively slow decay rate at peripheral region of the tumour tissues, which was found in the image obtained by MRRI, may contribute to the slower decay rates observed by EPRS and/or the EPRI measurements. To reliably determine the tissue redox status from the reduction rates of nitroxyls such as CmP, heterogenic structure in the tumour tissue must be considered. The high spatial and temporal resolution of T1 -weighted MRI and the T1 -enhancing capabilities of nitroxyls support the use of this method to map tissueAbstract: In vivo decay rates of a nitroxyl contrast agent were estimated by a MR redox imaging (MRRI) technique and compared with the decay rates obtained by the electron paramagnetic resonance spectroscopy (EPRS) and imaging (EPRI). MRRI is a dynamic imaging technique employing T1 -weighted pulse sequence, which can visualise a nitroxyl-induced enhancement of signal intensity by T1 -weighted contrast. EPR techniques can directly measure the paramagnetic nitroxyl radical. Both the squamous cell carcinoma (SCC) tumour-bearing and normal legs of a female C3H mouse were scanned by T1 -weighted SPGR sequence at 4.7 T with the nitroxyl radical, carbamoyl-proxyl (CmP), as the contrast agent. Similarly, the time course of CmP in normal muscle and tumour tissues was obtained using a 700-MHz EPR spectrometer with a surface coil. The time course imaging of CmP was also performed by 300 MHz CW EPR imager. EPRS and EPRI gave slower decay rates of CmP compared to the MRRI. Relatively slow decay rate at peripheral region of the tumour tissues, which was found in the image obtained by MRRI, may contribute to the slower decay rates observed by EPRS and/or the EPRI measurements. To reliably determine the tissue redox status from the reduction rates of nitroxyls such as CmP, heterogenic structure in the tumour tissue must be considered. The high spatial and temporal resolution of T1 -weighted MRI and the T1 -enhancing capabilities of nitroxyls support the use of this method to map tissue redox status which can be a useful biomarker to guide appropriate treatments based on the tumour microenvironment. … (more)
- Is Part Of:
- Free radical research. Volume 52:Number 2(2018)
- Journal:
- Free radical research
- Issue:
- Volume 52:Number 2(2018)
- Issue Display:
- Volume 52, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 52
- Issue:
- 2
- Issue Sort Value:
- 2018-0052-0002-0000
- Page Start:
- 248
- Page End:
- 255
- Publication Date:
- 2018-02-01
- Subjects:
- Electron paramagnetic resonance -- magnetic resonance functional imaging -- nitroxide radical -- redox mapping -- redox sensitive contrast agent -- tumour physiology
Free radicals (Chemistry) -- Periodicals
Antioxidants -- Periodicals
Vitamin C -- Periodicals
Vitamin E -- Periodicals
541.224 - Journal URLs:
- http://informahealthcare.com/journal/fra ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/10715762.2018.1427235 ↗
- Languages:
- English
- ISSNs:
- 1071-5762
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4033.326495
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: