PWE-049 Small-Bowel Capsule Endoscopy with 360° Panoramic-View: Results of The First Multicenter, Observational, Study. (17th August 2016)
- Record Type:
- Journal Article
- Title:
- PWE-049 Small-Bowel Capsule Endoscopy with 360° Panoramic-View: Results of The First Multicenter, Observational, Study. (17th August 2016)
- Main Title:
- PWE-049 Small-Bowel Capsule Endoscopy with 360° Panoramic-View: Results of The First Multicenter, Observational, Study
- Authors:
- Tontini, GE
Wiedbrauck, F
Cavallaro, F
Marino, R
Spina, L
McAlindon, ME
Koulaouzidis, A
Rondonotti, E
Pastorelli, L
Vecchi, M - Abstract:
- Abstract : Introduction: CapsoCam®SV (CapsoVision Inc, Saratoga, USA) is a new small bowel capsule (SBC) with "panoramic view", wire-free technology, and a long-lasting battery life. It is equipped with 4 high-frame rate cameras resulting in a high number of acquired frames. In previous studies, CapsoCam®SV showed comparable operative and diagnostic performance with frontal view SBCs. 1, 2 Methods: First multicenter study to assess the performance of CapsoCam®SV1 and SV2. Between January 2011 and November 2015, all consecutive patients undergoing SBC with CapsoCam® in 4 Italian, 2 British, and 1 German Institution(s) were included. Findings were classified according to their clinical significance, in line with Saurin classification, as P0: low probability; P1: intermediate probability; P2: high probability. 3 We defined SBC as "positive" when at least one P2 finding was identified. Results: We enrolled 172 patients (94 M; median age±SD: 68±17 years, range: 9–97 years). Of them, 142 were referred for obscure GI bleeding (32 overt/110 occult OGIB) and 28 for suspected (17) or established (2) Crohn's disease (CD). Median battery life was 16.4 h (range 3.7–23.4 h). System failure occurred in 4 (2%) cases for technical problems; incomplete enteroscopy in 16/168 (9%), including two structuring disorders (i.e. stricturing CD & SB adenocarcinoma) with spontaneous capsule excretion and one stricturing SB carcinoid with capsule retrieval at time of surgery.The ampulla of Vater wasAbstract : Introduction: CapsoCam®SV (CapsoVision Inc, Saratoga, USA) is a new small bowel capsule (SBC) with "panoramic view", wire-free technology, and a long-lasting battery life. It is equipped with 4 high-frame rate cameras resulting in a high number of acquired frames. In previous studies, CapsoCam®SV showed comparable operative and diagnostic performance with frontal view SBCs. 1, 2 Methods: First multicenter study to assess the performance of CapsoCam®SV1 and SV2. Between January 2011 and November 2015, all consecutive patients undergoing SBC with CapsoCam® in 4 Italian, 2 British, and 1 German Institution(s) were included. Findings were classified according to their clinical significance, in line with Saurin classification, as P0: low probability; P1: intermediate probability; P2: high probability. 3 We defined SBC as "positive" when at least one P2 finding was identified. Results: We enrolled 172 patients (94 M; median age±SD: 68±17 years, range: 9–97 years). Of them, 142 were referred for obscure GI bleeding (32 overt/110 occult OGIB) and 28 for suspected (17) or established (2) Crohn's disease (CD). Median battery life was 16.4 h (range 3.7–23.4 h). System failure occurred in 4 (2%) cases for technical problems; incomplete enteroscopy in 16/168 (9%), including two structuring disorders (i.e. stricturing CD & SB adenocarcinoma) with spontaneous capsule excretion and one stricturing SB carcinoid with capsule retrieval at time of surgery.The ampulla of Vater was clearly identified in 34% cases. The overall diagnostic yield (DY; rate of positive tests) was 41%; 43% in OGIB and 30% in suspected CD. In a per-lesion analysis, overall 560 findings were detected (P0: 55, P1: 253, P2: 252). Most lesions were located in the small bowel (448/560: 80%); 48% of them were P2. Interestingly, 95/560 (17%) and 17/560 (3%) lesions were detected in the upper and in the lower GI tract, 34 and 12 of them being classified as P2, respectively. Conclusion: The first multicenter study conducted in the everyday clinical practice with CapsoCam®SV, and based on the largest series so far collected, showed that SBC with 360° panoramic-view is easy to use, reliable, and has comparable DY and safety profile to forward view SCE. References: 1 Friedrich K, et al . J Gastroenterol Hepatol 2013;28 (9):1496–501. 2 Pioche M, et al . Endoscopy 2014;46 (6):479–84. 3 Saurin JC, et al . Endoscopy 2003;35 (7):576–84. Disclosure of Interest: None Declared … (more)
- Is Part Of:
- Gut. Volume 65(2016)Supplement 1
- Journal:
- Gut
- Issue:
- Volume 65(2016)Supplement 1
- Issue Display:
- Volume 65, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 65
- Issue:
- 1
- Issue Sort Value:
- 2016-0065-0001-0000
- Page Start:
- A162
- Page End:
- A163
- Publication Date:
- 2016-08-17
- Subjects:
- Gastroenterology -- Periodicals
616.33 - Journal URLs:
- http://gut.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/gutjnl-2016-312388.295 ↗
- Languages:
- English
- ISSNs:
- 0017-5749
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18592.xml