PWE-115 Detection and Characterisation of Colorectal Polyps Using High Definition White Light and I-Scan: Evidence and Delphi Process-Based Consensus Recommendations. (17th August 2016)
- Record Type:
- Journal Article
- Title:
- PWE-115 Detection and Characterisation of Colorectal Polyps Using High Definition White Light and I-Scan: Evidence and Delphi Process-Based Consensus Recommendations. (17th August 2016)
- Main Title:
- PWE-115 Detection and Characterisation of Colorectal Polyps Using High Definition White Light and I-Scan: Evidence and Delphi Process-Based Consensus Recommendations
- Authors:
- Bhandari, P
Thayalasekaran, S
Helmut, N
Kiesslich, R
Sanduleanu, S - Abstract:
- Abstract : Introduction: Electronic imaging technologies such as i-Scan, Narrow Band Imaging (NBI) and Fujinon Intelligence Colour Enhancement (FICE) are increasingly used for polyp detection and characterisation, but to date, their use is limited to expert settings. I-scan is a relatively novel technology. Insufficient literature with i-scan and the lack of RCT's hinder its implementation in clinical practice. Our goal was to review the current literature on the clinical utility of i-scan and develop evidence-based practical recommendations. Methods: We conducted a systematic review on the role of high definition white-light (HDWL) and i-Scan colonoscopy for polyp detection and characterisation. A series of evidence-based statements were developed and put through anonymous voting along the lines of a modified Delphi process. A one day consensus meeting was held (June 20, 2015, Milan). Each statement was voted until consensus (i.e >80% agreement) was achieved or rejection agreed. GRADE recommendations were assigned to the agreed statements. Results: The Consensus Panel consisted of 11 international experts. In total, 11 statements were proposed, of which 9 achieved consensus: HDWL is recommended rather than standard definition (SD) for the detection and characterisation of colorectal polyps; HDWL + i-Scan improves polyp and adenoma detection rates; HDWL + i-Scan are superior to HDWL alone for the optical diagnosis of colorectal polyps; HDWL + i-Scan in expert hands meet theAbstract : Introduction: Electronic imaging technologies such as i-Scan, Narrow Band Imaging (NBI) and Fujinon Intelligence Colour Enhancement (FICE) are increasingly used for polyp detection and characterisation, but to date, their use is limited to expert settings. I-scan is a relatively novel technology. Insufficient literature with i-scan and the lack of RCT's hinder its implementation in clinical practice. Our goal was to review the current literature on the clinical utility of i-scan and develop evidence-based practical recommendations. Methods: We conducted a systematic review on the role of high definition white-light (HDWL) and i-Scan colonoscopy for polyp detection and characterisation. A series of evidence-based statements were developed and put through anonymous voting along the lines of a modified Delphi process. A one day consensus meeting was held (June 20, 2015, Milan). Each statement was voted until consensus (i.e >80% agreement) was achieved or rejection agreed. GRADE recommendations were assigned to the agreed statements. Results: The Consensus Panel consisted of 11 international experts. In total, 11 statements were proposed, of which 9 achieved consensus: HDWL is recommended rather than standard definition (SD) for the detection and characterisation of colorectal polyps; HDWL + i-Scan improves polyp and adenoma detection rates; HDWL + i-Scan are superior to HDWL alone for the optical diagnosis of colorectal polyps; HDWL + i-Scan in expert hands meet the ASGE PIVI standards for the optical diagnosis of diminutive polyps; HDWL+i-Scan in non-expert hands do not meet the ASGE PIVI standards for the optical diagnosis of diminutive polyps; Optical diagnosis of polyps with i-Scan has a learning curve and needs systematic training; The performance of i-Scan for real time characterisation of colorectal polyps is similar to NBI & FICE. Two statements failed to achieve consensus: HDWL alone can be effective for the in-vivo characterisation of polyps in expert hands; The adenoma detection rate is comparable when using HDWL + i-scan versus chromoendoscopy. Conclusion: The Consensus Panel proposes evidence-based recommendations for the detection and characterisation of colorectal polyps using high-definition white light endoscopy and i-scan, to facilitate implementation of this technology in clinical practice. Areas of uncertainty, controversy and future research needs are addressed. Disclosure of Interest: None Declared … (more)
- Is Part Of:
- Gut. Volume 65(2016)Supplement 1
- Journal:
- Gut
- Issue:
- Volume 65(2016)Supplement 1
- Issue Display:
- Volume 65, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 65
- Issue:
- 1
- Issue Sort Value:
- 2016-0065-0001-0000
- Page Start:
- A195
- Page End:
- A195
- Publication Date:
- 2016-08-17
- Subjects:
- Gastroenterology -- Periodicals
616.33 - Journal URLs:
- http://gut.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/gutjnl-2016-312388.360 ↗
- Languages:
- English
- ISSNs:
- 0017-5749
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18592.xml