ASSA13-02-22 Application of a Novel Pacing Guide Wire in Cardiac Resynchronization Therapy. (29th April 2013)
- Record Type:
- Journal Article
- Title:
- ASSA13-02-22 Application of a Novel Pacing Guide Wire in Cardiac Resynchronization Therapy. (29th April 2013)
- Main Title:
- ASSA13-02-22 Application of a Novel Pacing Guide Wire in Cardiac Resynchronization Therapy
- Authors:
- Hai-bo, Yu
Yan-chun, Liang
Zu-lu, Wang
Yi, Sun
Guo-qing, Xu
Zhi-qing, Jin
Shi-bei, Li
Liu-jing, Fu
Ya-ling, Han - Abstract:
- Abstract : Background: The implantation of left ventricular (LV) lead was the most complicated process in the cardiac resynchronization therapy (CRT), the aim of this study was to investigate the availability of a novel Visionwire guide wire in the implantation ofLVlead in CRT. Methods: Five heart failure patients selected for CRT were involved in the study. The pacing threshold, R-wave sensing, phrenic nerve stimulation at local coronary sinus (CS) branch were measured by the Visionwire guide wire and LV lead separately. Results: The pacing parameters were analysed through the Visionwire guide wire and LV lead separately at the 16 CS branches in 5 patients. There was no significant difference between the pacing parameters measured by the two methods. Significant correlation was found betweenLVpacing threshold assessed by the Visionwire guide wire andLVlead (r = 0.90, P < 0.01). Correlation for R wave sensing was also significant (r = 0.67, P < 0.01). The pacing sites accompanied with phrenic nerve stimulation while pacing at 10 V/0.42 ms were similar by the two methods. Visionwire guide wire could be used for local potential electrical mapping. The procedure time for pacing test in a single coronary sinus branch by Visionwire guide wire was much less than that by LV lead (12.4 ± 7.5min vs 18.3 ± 12.2min, P < 0.01). Conclusions: Visionwire guide wire facilitated transvenousLVlead implantation by prediction of pacing parameter and locate the target CS branch quickly. TheAbstract : Background: The implantation of left ventricular (LV) lead was the most complicated process in the cardiac resynchronization therapy (CRT), the aim of this study was to investigate the availability of a novel Visionwire guide wire in the implantation ofLVlead in CRT. Methods: Five heart failure patients selected for CRT were involved in the study. The pacing threshold, R-wave sensing, phrenic nerve stimulation at local coronary sinus (CS) branch were measured by the Visionwire guide wire and LV lead separately. Results: The pacing parameters were analysed through the Visionwire guide wire and LV lead separately at the 16 CS branches in 5 patients. There was no significant difference between the pacing parameters measured by the two methods. Significant correlation was found betweenLVpacing threshold assessed by the Visionwire guide wire andLVlead (r = 0.90, P < 0.01). Correlation for R wave sensing was also significant (r = 0.67, P < 0.01). The pacing sites accompanied with phrenic nerve stimulation while pacing at 10 V/0.42 ms were similar by the two methods. Visionwire guide wire could be used for local potential electrical mapping. The procedure time for pacing test in a single coronary sinus branch by Visionwire guide wire was much less than that by LV lead (12.4 ± 7.5min vs 18.3 ± 12.2min, P < 0.01). Conclusions: Visionwire guide wire facilitated transvenousLVlead implantation by prediction of pacing parameter and locate the target CS branch quickly. The electrophysiological mapping function of Visionwire guide wire as a unipolar lead might have further potential usefulness. … (more)
- Is Part Of:
- Heart. Volume 99(2013)Supplement 1
- Journal:
- Heart
- Issue:
- Volume 99(2013)Supplement 1
- Issue Display:
- Volume 99, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 99
- Issue:
- 1
- Issue Sort Value:
- 2013-0099-0001-0000
- Page Start:
- A11
- Page End:
- A11
- Publication Date:
- 2013-04-29
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2013-303992.035 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18558.xml