ASSA13-03-12 Investigation of X- Radiation Dose to Subjects in the Comprehensive Surgical Treatment Field Shelter During Interventional Therapy. (29th April 2013)
- Record Type:
- Journal Article
- Title:
- ASSA13-03-12 Investigation of X- Radiation Dose to Subjects in the Comprehensive Surgical Treatment Field Shelter During Interventional Therapy. (29th April 2013)
- Main Title:
- ASSA13-03-12 Investigation of X- Radiation Dose to Subjects in the Comprehensive Surgical Treatment Field Shelter During Interventional Therapy
- Authors:
- Hui-yu, Shao
Ming, Liang
Xiao-zeng, Wang
Tian-ming, Yao
Jing-yang, Sun
Geng, Wang
Meng, Wang
Ya-ling, Han - Abstract:
- Abstract : Background: Comprehensive surgical treatment field shelter are developed by our centre used in field support and disaster emergency rescue. Intervention, minimally invasive and conventional surgery as the main means of this system, to belly department, limbs and skull important viscera urgent heavy damage and disease can be effectively damage control treatment. But in the shelter within the intervention in the process of diagnosis and treatment, the radiation dose safety is also an important problem. We determine the dose level in different conditions, in order to provide scientific and reasonable measures and Methods:of protection to reduce radiation doses for subjects. Methods: Measure DAP and ESD values with an Alderson phantom for the two types of different impulse frequency (4 fps/s, 8 fps/s, 12 fps/s) and different perspective voltage (80kv, 90kv, 100kv) separated into fluoroscopy and digital acquisition. Results: The group of different impulse frequency (4 fps/s, 8 fps/s, 12 fps/s): the fluoroscopy dose values of DAP in this serial measured respectively for5.86 ± 0.01 μGym 2 /s, 11.66 ± 0.17 μGym 2 /s, 13.97 ± 0.05 μGym 2 /s, and ESD was 8500.27 ± 23.86 μGy/s, 16849.30 ± 71.44 μGy/s, 24630.75 ± 135.20 μGy/s; the digital acquisition dose values of DAP was19.63 ± 0.02 μGym 2 (10frame), 38.98 ± 0.06 μGym 2 (10 frame), 44.81 ± 0.06 μGym 2 (10 frame), and ESD was 28753.70 ± 605.13 μGy (10 frame), 57451.23 ± 637.47 μGy (10 frame), 81950.62 ± 523.37 μGy (10Abstract : Background: Comprehensive surgical treatment field shelter are developed by our centre used in field support and disaster emergency rescue. Intervention, minimally invasive and conventional surgery as the main means of this system, to belly department, limbs and skull important viscera urgent heavy damage and disease can be effectively damage control treatment. But in the shelter within the intervention in the process of diagnosis and treatment, the radiation dose safety is also an important problem. We determine the dose level in different conditions, in order to provide scientific and reasonable measures and Methods:of protection to reduce radiation doses for subjects. Methods: Measure DAP and ESD values with an Alderson phantom for the two types of different impulse frequency (4 fps/s, 8 fps/s, 12 fps/s) and different perspective voltage (80kv, 90kv, 100kv) separated into fluoroscopy and digital acquisition. Results: The group of different impulse frequency (4 fps/s, 8 fps/s, 12 fps/s): the fluoroscopy dose values of DAP in this serial measured respectively for5.86 ± 0.01 μGym 2 /s, 11.66 ± 0.17 μGym 2 /s, 13.97 ± 0.05 μGym 2 /s, and ESD was 8500.27 ± 23.86 μGy/s, 16849.30 ± 71.44 μGy/s, 24630.75 ± 135.20 μGy/s; the digital acquisition dose values of DAP was19.63 ± 0.02 μGym 2 (10frame), 38.98 ± 0.06 μGym 2 (10 frame), 44.81 ± 0.06 μGym 2 (10 frame), and ESD was 28753.70 ± 605.13 μGy (10 frame), 57451.23 ± 637.47 μGy (10 frame), 81950.62 ± 523.37 μGy (10 frame). The group of different perspective voltage (80 kv, 90 kv, 100 kv): the fluoroscopy dose values of DAP in this serial measured respectively for 13.97 ± 0.05 μGym 2 /s, 11.66 ± 0.17 μGym 2 /s, 13.97 ± 0.05 μGym 2 /s, and ESD was 24630.75 ± 135.24μGy/s, 38847.94 ± 27.63μGy/s, 24630.75 ± 135.20μGy/s; the digital acquisition dose values of DAP was 44.81 ± 0.06 uGym 2 (10 frame), 57.09 ± 0.14 μGym 2 (10 frame), 76.48 ± 0.21 μGym 2 (10 frame), and ESD was 81950.62 ± 523.37 μGy (10 frame), 117842.01 ± 636.46 μGy (10 frame), 160025.91 ± 852.31μGy (10 frame). There were statistical difference of dose DAP and ESD in different groups. ( p < 0.01). Conclusions: The higher the impulse frequency and perspective voltage, the higher the radiation dose. So in order to ensure the quality of image premise, As low as possible to reduce impulse frequency and perspective voltage, and take effective protective measures to reduce the subjects ' radiation dose. … (more)
- Is Part Of:
- Heart. Volume 99(2013)Supplement 1
- Journal:
- Heart
- Issue:
- Volume 99(2013)Supplement 1
- Issue Display:
- Volume 99, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 99
- Issue:
- 1
- Issue Sort Value:
- 2013-0099-0001-0000
- Page Start:
- A17
- Page End:
- A18
- Publication Date:
- 2013-04-29
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2013-303992.052 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18558.xml