040 Outcomes following transcatheter aortic valve implantation comparing Edwards SAPIEN with Medtronic CoreValve ReValving system devices: results from the Milan registry. (16th May 2012)
- Record Type:
- Journal Article
- Title:
- 040 Outcomes following transcatheter aortic valve implantation comparing Edwards SAPIEN with Medtronic CoreValve ReValving system devices: results from the Milan registry. (16th May 2012)
- Main Title:
- 040 Outcomes following transcatheter aortic valve implantation comparing Edwards SAPIEN with Medtronic CoreValve ReValving system devices: results from the Milan registry
- Authors:
- Buchanan, G L
Chieffo, A
Montorfano, M
Maisano, F
Latib, A
Cioni, M
Figini, F
Carlino, M
Covello, R D
Franco, A
Gerli, C
Grimaldi, A
La Canna, G
Spagnolo, P
Alfieri, O
Colombo, A - Abstract:
- Abstract : Background: To assess clinical outcomes of transcatheter aortic valve implantation comparing Medtronic CoreValve ReValving System® with Edwards SAPIEN XT. Methods: All consecutive patients in our center with aortic stenosis treated with transfemoral Medtronic CoreValve ReValving System® (MCV) from November 2009 to September 2011 (learning curve patients excluded) or Edwards SAPIEN XT (ESV) from April 2010 to September 2011 when the device became available were included. Results: In total, there were 192 patients in this analysis. The overall mean age was 79.4±8.1 years, logistic EuroSCORE 21.1±15.9% and STS-PROM score 8.8±8.6%. The MCV group consisted of a greater proportion of males (60.3% vs 43.7%; p=0.026) with a corresponding larger aortic annulus size (24.7±2.0 vs 23.4±1.7; p<0.001). The median clinical follow-up length was 171 (IQR 54–357) days. 30-day all cause mortality was 4.0%, myocardial infarction rate 1.0% and stroke 0.5%, with no differences between valve types. Life-threatening bleeding occurred in 14.7% and 11.5% had a major vascular complication. There were no differences in the combined safety endpoint at 30 days (ESV 72.2% vs MCV 71.9%; p=0.936). However, there was a significantly higher rate of device success among the ESV group (98.3% vs 90.4%; p=0.012) with additionally a significantly higher rate of conduction disturbances/arrhythmia (31.5% vs 16.0%; p=0.011) as well as pacemaker implantation (28.8% vs 5.0%; p<0.001) with MCV compared withAbstract : Background: To assess clinical outcomes of transcatheter aortic valve implantation comparing Medtronic CoreValve ReValving System® with Edwards SAPIEN XT. Methods: All consecutive patients in our center with aortic stenosis treated with transfemoral Medtronic CoreValve ReValving System® (MCV) from November 2009 to September 2011 (learning curve patients excluded) or Edwards SAPIEN XT (ESV) from April 2010 to September 2011 when the device became available were included. Results: In total, there were 192 patients in this analysis. The overall mean age was 79.4±8.1 years, logistic EuroSCORE 21.1±15.9% and STS-PROM score 8.8±8.6%. The MCV group consisted of a greater proportion of males (60.3% vs 43.7%; p=0.026) with a corresponding larger aortic annulus size (24.7±2.0 vs 23.4±1.7; p<0.001). The median clinical follow-up length was 171 (IQR 54–357) days. 30-day all cause mortality was 4.0%, myocardial infarction rate 1.0% and stroke 0.5%, with no differences between valve types. Life-threatening bleeding occurred in 14.7% and 11.5% had a major vascular complication. There were no differences in the combined safety endpoint at 30 days (ESV 72.2% vs MCV 71.9%; p=0.936). However, there was a significantly higher rate of device success among the ESV group (98.3% vs 90.4%; p=0.012) with additionally a significantly higher rate of conduction disturbances/arrhythmia (31.5% vs 16.0%; p=0.011) as well as pacemaker implantation (28.8% vs 5.0%; p<0.001) with MCV compared with ESV. Conclusions: In our single center experience, transcatheter aortic valve implantation was a relatively safe and effective procedure utilising both commercially available devices. However, there was an increased incidence of arrhythmia and pacemaker implantation in the MCV group. … (more)
- Is Part Of:
- Heart. Volume 98(2012)Supplement 1
- Journal:
- Heart
- Issue:
- Volume 98(2012)Supplement 1
- Issue Display:
- Volume 98, Issue 1 (2012)
- Year:
- 2012
- Volume:
- 98
- Issue:
- 1
- Issue Sort Value:
- 2012-0098-0001-0000
- Page Start:
- A25
- Page End:
- A25
- Publication Date:
- 2012-05-16
- Subjects:
- Transcatheter aortic valve implantation -- aortic stenosis -- transfemoral
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2012-301877b.40 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18568.xml