25 A study of the different methodologies used in calculation of extra-cellular volume by CMR imaging. (May 2018)
- Record Type:
- Journal Article
- Title:
- 25 A study of the different methodologies used in calculation of extra-cellular volume by CMR imaging. (May 2018)
- Main Title:
- 25 A study of the different methodologies used in calculation of extra-cellular volume by CMR imaging
- Authors:
- Vijapurapu, Ravi
Hawkins, Francesca
Liu, Boyang
Edwards, Nicola
Steeds, Richard - Abstract:
- Abstract : Introduction: Tissue characterisation with MRI derived extra-cellular volume (ECV) measurement using T1 mapping is a well-recognised tool guiding clinical diagnosis and treatment. Concerns regarding blood-pool artefact have led to multiple methodologies with no consistency in assessment. This study investigates how ECV values and inter-observer reproducibility varies depending on technique. Methods: Patients with primary mitral regurgitation (MR) underwent multiparametric CMR imaging (1.5 T Siemens Avanto). ECV was calculated using MOLLI-derived T1 mapping (mid- and basal-LV, CircleCvi42) by two methods: global segmental analyses with variable endocardial:epicardial percentage offsets (20:20, 0:50, 10:50, 20:50) and region of interest (ROI). A second observer independently analysed a subset for inter-observer reproducibility, with independent exclusion of artefactual segments. Results: Thirty patients were studied (LVEF 72%±7%, LVEDVi 101±19 ml/m 2, LVESVi 30±11 ml/m 2, MR fraction 41%±16%, age 66±11 years). ECV values were lowest using ROI (septum 26.0%±2.5%, anterior 26.0%±0.26%, posterior 26.3%±0.39%), followed by 20:20 offset (28.0%±3.3%), and were highest with 0:50 offset (29.9%±3.4%). A 20:20 offset approach was most reproducible following 8% segmental exclusion (mean bias 0.21%±0.12%, intraclass correlation (ICC) 0.994), followed by 20:50, 10:50, and 0:50 offsets (mean bias 0.39%±0.24%, ICC 0.992). Anterior ROI was more reproducible than septal (mean biasAbstract : Introduction: Tissue characterisation with MRI derived extra-cellular volume (ECV) measurement using T1 mapping is a well-recognised tool guiding clinical diagnosis and treatment. Concerns regarding blood-pool artefact have led to multiple methodologies with no consistency in assessment. This study investigates how ECV values and inter-observer reproducibility varies depending on technique. Methods: Patients with primary mitral regurgitation (MR) underwent multiparametric CMR imaging (1.5 T Siemens Avanto). ECV was calculated using MOLLI-derived T1 mapping (mid- and basal-LV, CircleCvi42) by two methods: global segmental analyses with variable endocardial:epicardial percentage offsets (20:20, 0:50, 10:50, 20:50) and region of interest (ROI). A second observer independently analysed a subset for inter-observer reproducibility, with independent exclusion of artefactual segments. Results: Thirty patients were studied (LVEF 72%±7%, LVEDVi 101±19 ml/m 2, LVESVi 30±11 ml/m 2, MR fraction 41%±16%, age 66±11 years). ECV values were lowest using ROI (septum 26.0%±2.5%, anterior 26.0%±0.26%, posterior 26.3%±0.39%), followed by 20:20 offset (28.0%±3.3%), and were highest with 0:50 offset (29.9%±3.4%). A 20:20 offset approach was most reproducible following 8% segmental exclusion (mean bias 0.21%±0.12%, intraclass correlation (ICC) 0.994), followed by 20:50, 10:50, and 0:50 offsets (mean bias 0.39%±0.24%, ICC 0.992). Anterior ROI was more reproducible than septal (mean bias 0.14%±0.72%, ICC 0.96 vs 0.48%±0.74%, ICC 0.929). Conclusion: There is considerable variability in ECV derived using ROI compared with a segmental approach, highlighting the importance of consistency within analyses. ECV calculation using septal ROI is commonly reported in the literature, but we have shown that a global segmental approach using 20:20 offsets have superior reproducibility, despite variable exclusion of artefactual segments. … (more)
- Is Part Of:
- Heart. Volume 104(2018)Supplement 5
- Journal:
- Heart
- Issue:
- Volume 104(2018)Supplement 5
- Issue Display:
- Volume 104, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 104
- Issue:
- 5
- Issue Sort Value:
- 2018-0104-0005-0000
- Page Start:
- A14
- Page End:
- A15
- Publication Date:
- 2018-05
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2018-BCVI.40 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18529.xml