54 ICD deactivation at end of life in Northern Ireland 2013–2015. (28th September 2016)
- Record Type:
- Journal Article
- Title:
- 54 ICD deactivation at end of life in Northern Ireland 2013–2015. (28th September 2016)
- Main Title:
- 54 ICD deactivation at end of life in Northern Ireland 2013–2015
- Authors:
- Noad, R
Hill, L
Dixon, L - Abstract:
- Abstract : Background: ICD patients may later develop a terminal illness. Concurrent hypoxia, sepsis, pain, heart failure and electrolyte disturbances may predispose shocks in final days of life which is distressing to both patients and their family. A previous audit within the Belfast Trust examined 44 patients with ICDs who died between 2012–2013 in which 16 (36.4%) had device deactivated pre-death. Our aim was to re-audit this for all Northern Ireland between 2013–2015. Methods: All patients who died with an ICD/CRT-D in situ between Sept 2013–Nov 2015 were included. Medical notes/and hospital electronic records were reviewed and patient and device characteristics recorded. Results: In total, 227 patients died with an implantable cardioverter defibrillator (ICD) in situ. Of these, 89 (39.2%) patients had their device deactivated prior to death to prevent inappropriate shock therapy, whilst 138 (60.8%) died with an active ICD in situ. Of the 138 that died with an active ICD: 17 (12.3%) had a diagnosis of a cancer for palliation only, a further 28 (20.3%) were being managed palliatively for non-cancerous conditions either in hospital or in the community and 7 (5.1%) patients were classified as having significant cognitive impairment. In this group ICD was mentioned in the most recent medical correspondence in 39 (28.2%). Overall, 65 (48.1%) had previously received a shock from their device, though previous history of shock did not influence likelihood of device deactivationAbstract : Background: ICD patients may later develop a terminal illness. Concurrent hypoxia, sepsis, pain, heart failure and electrolyte disturbances may predispose shocks in final days of life which is distressing to both patients and their family. A previous audit within the Belfast Trust examined 44 patients with ICDs who died between 2012–2013 in which 16 (36.4%) had device deactivated pre-death. Our aim was to re-audit this for all Northern Ireland between 2013–2015. Methods: All patients who died with an ICD/CRT-D in situ between Sept 2013–Nov 2015 were included. Medical notes/and hospital electronic records were reviewed and patient and device characteristics recorded. Results: In total, 227 patients died with an implantable cardioverter defibrillator (ICD) in situ. Of these, 89 (39.2%) patients had their device deactivated prior to death to prevent inappropriate shock therapy, whilst 138 (60.8%) died with an active ICD in situ. Of the 138 that died with an active ICD: 17 (12.3%) had a diagnosis of a cancer for palliation only, a further 28 (20.3%) were being managed palliatively for non-cancerous conditions either in hospital or in the community and 7 (5.1%) patients were classified as having significant cognitive impairment. In this group ICD was mentioned in the most recent medical correspondence in 39 (28.2%). Overall, 65 (48.1%) had previously received a shock from their device, though previous history of shock did not influence likelihood of device deactivation (p = 0.665). Conclusion: Communication about ICD deactivation at end of life should be standard practice. More work is needed to ensure this occurs in an appropriate and timely manner. … (more)
- Is Part Of:
- Heart. Volume 102(2016)Supplement 9
- Journal:
- Heart
- Issue:
- Volume 102(2016)Supplement 9
- Issue Display:
- Volume 102, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 102
- Issue:
- 9
- Issue Sort Value:
- 2016-0102-0009-0000
- Page Start:
- A28
- Page End:
- A28
- Publication Date:
- 2016-09-28
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2016-310523.54 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18525.xml