117 Optimisation and Reproducibility of 18F-Fluoride Positron Emission Tomography and Computed Tomography in Patients with Aortic Stenosis. (3rd June 2016)
- Record Type:
- Journal Article
- Title:
- 117 Optimisation and Reproducibility of 18F-Fluoride Positron Emission Tomography and Computed Tomography in Patients with Aortic Stenosis. (3rd June 2016)
- Main Title:
- 117 Optimisation and Reproducibility of 18F-Fluoride Positron Emission Tomography and Computed Tomography in Patients with Aortic Stenosis
- Authors:
- Pawade, Tania
Cartlidge, Timothy
Newby, David
Marc, Dweck - Abstract:
- Abstract : Background: 18F-Fluoride positron emission tomography (PET) and computed tomography (CT) can measure disease activity and progression in aortic stenosis. We aimed to optimise imaging methodology, analysis and scan-rescan reproducibility. Methods: Fifteen patients with aortic stenosis underwent 18F-fluoride PET-CT twice within 1 month. We compared non-gated PET and non-contrast CT, with a modified approach that incorporated contrast CT and ECG-gated PET. We explored a range of image analysis techniques including estimation of blood pool activity at differing vascular sites and a most-diseased segment (MDS) approach. Results: Contrast-enhanced ECG-gated PET-CT provided superior spatial localisation of 18F-fluoride uptake that permitted localisation to individual valve leaflets (Figure ). Scan-rescan reproducibility was markedly improved using enhanced analysis techniques leading to a reduction in variability from 25% to <10% (tissue-to-background MDS: mean value 1.55, difference 0.05, limits of agreement -0·10 to 0·20). Conclusion: Optimised 18F-fluoride PET-CT provides excellent spatial resolution and scan-rescan reproducibility. It holds major promise as a marker of disease activity in aortic stenosis and has major potential as a biomarker end-point of trials of novel therapies in aortic stenosis.
- Is Part Of:
- Heart. Volume 102(2016)Supplement 6
- Journal:
- Heart
- Issue:
- Volume 102(2016)Supplement 6
- Issue Display:
- Volume 102, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 102
- Issue:
- 6
- Issue Sort Value:
- 2016-0102-0006-0000
- Page Start:
- A82
- Page End:
- A82
- Publication Date:
- 2016-06-03
- Subjects:
- Aortic Stenosis -- 18F-Fluoride Positron Emission Tomography -- Computed Tomography
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2016-309890.117 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18523.xml