28 Haemodynamic performance of supra-annular versus intra-annular transcatheter heart valves in failed bioprostheses. (24th April 2016)
- Record Type:
- Journal Article
- Title:
- 28 Haemodynamic performance of supra-annular versus intra-annular transcatheter heart valves in failed bioprostheses. (24th April 2016)
- Main Title:
- 28 Haemodynamic performance of supra-annular versus intra-annular transcatheter heart valves in failed bioprostheses
- Authors:
- Silaschi, M
Wendler, O
Castro, L
Aldalati, O
Reichenspurner, H
Blankenberg, S
Schaefer, U
MacCarthy, P
Conradi, L - Abstract:
- Abstract : Background: Transcatheter aortic valve-in-valve implantation (ViV) is increasingly used to treat failed bioprostheses (BP), but elevated gradients remain a challenge. In-vitro studies suggest transcatheter heart valves (THV) with supra-annular position improve haemodynamic results compared to THV with intra-anular position. Methods: We compared haemodynamic performance. Methods: Since 2008, 71 patients underwent ViV using the Medtronic CoreValve /Evolut-R (CV) or Edwards Sapien /XT/3 THV (ES). Patients were matched regarding true internal diameter (ID) and mode of degeneration (MoD) (CV=22, ES=19). Results: In the total group, CV were implanted into smaller BP than ES (true ID: 19.0 ± 2.1mm vs. 21.4 ± 2.7mm, p < 0.01). After matching, true ID was 19.4 ± 2.0mm in both groups, p = 0.92. MoD, BSA and left ventricular function were not significantly different. Baseline mean gradients (CV: 39.0 ± 17.2mmHg vs. ES: 38.0 ± 19.5mmHg, p = 0.86) and indexed effective orifice areas (iEOA; CV: 0.79 ± 0.11cm²/m² vs. ES: 0.80 ± 0.10cm²/m², p = 0.64) were comparable. At discharge, mean gradients were 22.0 ± 7.7mmHg (CV) vs. 20.0 ± 7.8 (ES, p = 0.43) and iEOA: 0.77 ± 0.14 cm²/m² (CV) vs 0.84 ± 0.21cm²/m² (ES, p = 0.28). In CV, 54.5% had a mean gradient ≥20mmHg, compared to 52.6% in ES, p = 1.0. There was no paravalvular regurgitation >1. Conclusion: In retrospect, haemodynamic performance of either CV or ES for ViV was not different and superiority of supra-annular THV remains toAbstract : Background: Transcatheter aortic valve-in-valve implantation (ViV) is increasingly used to treat failed bioprostheses (BP), but elevated gradients remain a challenge. In-vitro studies suggest transcatheter heart valves (THV) with supra-annular position improve haemodynamic results compared to THV with intra-anular position. Methods: We compared haemodynamic performance. Methods: Since 2008, 71 patients underwent ViV using the Medtronic CoreValve /Evolut-R (CV) or Edwards Sapien /XT/3 THV (ES). Patients were matched regarding true internal diameter (ID) and mode of degeneration (MoD) (CV=22, ES=19). Results: In the total group, CV were implanted into smaller BP than ES (true ID: 19.0 ± 2.1mm vs. 21.4 ± 2.7mm, p < 0.01). After matching, true ID was 19.4 ± 2.0mm in both groups, p = 0.92. MoD, BSA and left ventricular function were not significantly different. Baseline mean gradients (CV: 39.0 ± 17.2mmHg vs. ES: 38.0 ± 19.5mmHg, p = 0.86) and indexed effective orifice areas (iEOA; CV: 0.79 ± 0.11cm²/m² vs. ES: 0.80 ± 0.10cm²/m², p = 0.64) were comparable. At discharge, mean gradients were 22.0 ± 7.7mmHg (CV) vs. 20.0 ± 7.8 (ES, p = 0.43) and iEOA: 0.77 ± 0.14 cm²/m² (CV) vs 0.84 ± 0.21cm²/m² (ES, p = 0.28). In CV, 54.5% had a mean gradient ≥20mmHg, compared to 52.6% in ES, p = 1.0. There was no paravalvular regurgitation >1. Conclusion: In retrospect, haemodynamic performance of either CV or ES for ViV was not different and superiority of supra-annular THV remains to be proven. Other factors, such as implantation depth of THV, may be more relevant for haemodynamic outcome and need further investigation. … (more)
- Is Part Of:
- Heart. Volume 102(2016)Supplement 4
- Journal:
- Heart
- Issue:
- Volume 102(2016)Supplement 4
- Issue Display:
- Volume 102, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 102
- Issue:
- 4
- Issue Sort Value:
- 2016-0102-0004-0000
- Page Start:
- A13
- Page End:
- A13
- Publication Date:
- 2016-04-24
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2016-309588.28 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18538.xml