24 Assessment of the effects of technique on pulmonary arterial pulse wave velocity measurement. (18th April 2016)
- Record Type:
- Journal Article
- Title:
- 24 Assessment of the effects of technique on pulmonary arterial pulse wave velocity measurement. (18th April 2016)
- Main Title:
- 24 Assessment of the effects of technique on pulmonary arterial pulse wave velocity measurement
- Authors:
- Weir-McCall, JR
Kamalasanan, A
Cassidy, DB
Struthers, AD
Lipworth, BJ
Houston, JG - Abstract:
- Abstract : Aim: The flow-area (QA) technique allows measurement of pulse wave velocity (PWV) from a single phase contrast slice. However in the pulmonary circulation reflected waves arrive during systole and may cause erroneous measurements using this technique. The aim of the study was to compare three post-processing calculations, one of which avoids the reflected wave, and the other which corrects for it, on the measurement of pulmonary PWV and its reproducibility. Materials and methods: 10 young healthy volunteers (YHV) (30% male, mean age 31.5 ± 7.6) and 20 older healthy volunteers (OHV) (45% male, mean age 60.2 ± 4.0) underwent MRI using phase contrast sequences through the main pulmonary artery (MPA), right pulmonary artery (RPA) and left pulmonary artery (LPA). Measurements were repeated at 6 months in the YHV cohort and on the same visit in the OHV cohort. QA PWV was calculated using three techniques: QATrad = ΔQ/ΔA; QA3 = ΔQ/ΔA (using only the first three datapoints in the reflectionless upstroke); and QAInv = √(∑ΔA 2 /∑ΔQ 2 ). Results: QATrad produced significantly higher results than QA3 (p < 0.001) and QAInv (p < 0.001), whilst there was no difference between QA3 and QAInv (p = 0.41). In scan-rescan reproducibility, QAInv yielded improved precision over QATrad and QA3 : mean (SD) of PWV differences = −0.46 (0.98) ms −1, 0.05 (0.88) ms −1, and 0.01 (0.63) ms −1 for the QATrad, QA3, and QAInv of the MPA respectively; 0.17 (0.43), 0.19 (0.83) and 0.06 (0.25) ms −1Abstract : Aim: The flow-area (QA) technique allows measurement of pulse wave velocity (PWV) from a single phase contrast slice. However in the pulmonary circulation reflected waves arrive during systole and may cause erroneous measurements using this technique. The aim of the study was to compare three post-processing calculations, one of which avoids the reflected wave, and the other which corrects for it, on the measurement of pulmonary PWV and its reproducibility. Materials and methods: 10 young healthy volunteers (YHV) (30% male, mean age 31.5 ± 7.6) and 20 older healthy volunteers (OHV) (45% male, mean age 60.2 ± 4.0) underwent MRI using phase contrast sequences through the main pulmonary artery (MPA), right pulmonary artery (RPA) and left pulmonary artery (LPA). Measurements were repeated at 6 months in the YHV cohort and on the same visit in the OHV cohort. QA PWV was calculated using three techniques: QATrad = ΔQ/ΔA; QA3 = ΔQ/ΔA (using only the first three datapoints in the reflectionless upstroke); and QAInv = √(∑ΔA 2 /∑ΔQ 2 ). Results: QATrad produced significantly higher results than QA3 (p < 0.001) and QAInv (p < 0.001), whilst there was no difference between QA3 and QAInv (p = 0.41). In scan-rescan reproducibility, QAInv yielded improved precision over QATrad and QA3 : mean (SD) of PWV differences = −0.46 (0.98) ms −1, 0.05 (0.88) ms −1, and 0.01 (0.63) ms −1 for the QATrad, QA3, and QAInv of the MPA respectively; 0.17 (0.43), 0.19 (0.83) and 0.06 (0.25) ms −1 for the QATrad, QA3, and QAInv of the RPA respectively; and −0.29 (0.31), −0.01 (0.39) and −0.06 (0.32) ms −1 for the QATrad, QA3, and QAInv of the LPA respectively (see Figure 1 ). Conclusion: Calculations which account for wave reflections yield lower PWV than those that don't suggesting significant confounding effects from these early reflected waves. Combining a phase contrast sequence acquisition through the right pulmonary artery with a post processing technique to account for wave reflections yields the most reproducible measurements of pulmonary PWV. … (more)
- Is Part Of:
- Heart. Volume 102(2016)Supplement 3
- Journal:
- Heart
- Issue:
- Volume 102(2016)Supplement 3
- Issue Display:
- Volume 102, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 102
- Issue:
- 3
- Issue Sort Value:
- 2016-0102-0003-0000
- Page Start:
- A18
- Page End:
- A19
- Publication Date:
- 2016-04-18
- Subjects:
- Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2016-309668.24 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18529.xml