Comparison of ERMI results for dust collected from homes by an electrostatic cloth and by the standard vacuum method. Issue 9 (27th August 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of ERMI results for dust collected from homes by an electrostatic cloth and by the standard vacuum method. Issue 9 (27th August 2021)
- Main Title:
- Comparison of ERMI results for dust collected from homes by an electrostatic cloth and by the standard vacuum method
- Authors:
- Vesper, Stephen
Wymer, Larry
Cox, David
Dewalt, Gary
Pinzer, Eugene
Friedman, Warren
Ashley, Peter J. - Abstract:
- Abstract: The Environmental Relative Moldiness Index (ERMI) is a scale used to compare mold contamination levels in U.S. homes. To create the ERMI scale, a nationally representative set of U.S. homes was selected (n = 1, 096). From each of these homes, a standard vacuum-dust sample was collected and then 36 common molds, the 26 Group 1 and 10 Group 2 molds, as grouped for forming the ERMI metric, were quantified using quantitative PCR assays. However, in investigations of mold in homes, it is not always practical or even possible to collect dust using the standard vacuum method. Therefore, we performed a comparative study of dust samples collected in the same homes (n = 151) by the standard vacuum method and by an electrostatic cloth (EC) method. First, floor dust was collected by vacuuming a 2 m 2 area in the living room and a 2 m 2 area in a bedroom, directly adjacent to the sofa or bed, for 5 min each with a Mitest sampler-fitted vacuum. Second, immediately after the collection of the vacuum dust sample, an EC dust sample was collected by wiping above-floor horizontal surfaces in the living room and bedroom. Then, the ERMI analysis of each sample was performed by a commercial laboratory. The results showed the average concentrations of 33 of the 36 ERMI molds were not significantly different in the vacuum and EC samples. Also, the average summed logs of the Group 1 molds, Group 2, or ERMI values were significantly ( p < 0.001) correlated between the vacuum and ECAbstract: The Environmental Relative Moldiness Index (ERMI) is a scale used to compare mold contamination levels in U.S. homes. To create the ERMI scale, a nationally representative set of U.S. homes was selected (n = 1, 096). From each of these homes, a standard vacuum-dust sample was collected and then 36 common molds, the 26 Group 1 and 10 Group 2 molds, as grouped for forming the ERMI metric, were quantified using quantitative PCR assays. However, in investigations of mold in homes, it is not always practical or even possible to collect dust using the standard vacuum method. Therefore, we performed a comparative study of dust samples collected in the same homes (n = 151) by the standard vacuum method and by an electrostatic cloth (EC) method. First, floor dust was collected by vacuuming a 2 m 2 area in the living room and a 2 m 2 area in a bedroom, directly adjacent to the sofa or bed, for 5 min each with a Mitest sampler-fitted vacuum. Second, immediately after the collection of the vacuum dust sample, an EC dust sample was collected by wiping above-floor horizontal surfaces in the living room and bedroom. Then, the ERMI analysis of each sample was performed by a commercial laboratory. The results showed the average concentrations of 33 of the 36 ERMI molds were not significantly different in the vacuum and EC samples. Also, the average summed logs of the Group 1 molds, Group 2, or ERMI values were significantly ( p < 0.001) correlated between the vacuum and EC samples. Logistic regression indicated that an EC sample could identify homes in the highest ERMI quartile 96% of the time by using the same ERMI value cutoff as vacuum sample ERMI value cutoff and 35% of samples proved to be false positives. When it is not practical to obtain the standard vacuum-dust sample, an EC sample can provide a useful practical alternative for ERMI analyses. … (more)
- Is Part Of:
- Journal of occupational and environmental hygiene. Volume 18:Issue 9(2021)
- Journal:
- Journal of occupational and environmental hygiene
- Issue:
- Volume 18:Issue 9(2021)
- Issue Display:
- Volume 18, Issue 9 (2021)
- Year:
- 2021
- Volume:
- 18
- Issue:
- 9
- Issue Sort Value:
- 2021-0018-0009-0000
- Page Start:
- 423
- Page End:
- 429
- Publication Date:
- 2021-08-27
- Subjects:
- American Healthy Homes Survey -- Department of Housing and Urban Development -- mold
Industrial hygiene -- Periodicals
Environmental health -- Periodicals
Medicine, Industrial -- Periodicals
Occupational Health -- Periodicals
Environmental Exposure -- Periodicals
Environmental Health -- Periodicals
Occupational Exposure -- Periodicals
Hygiène industrielle -- Périodiques
Hygiène du milieu -- Périodiques
Médecine du travail -- Périodiques
613.62 - Journal URLs:
- http://www.tandfonline.com/ ↗
- DOI:
- 10.1080/15459624.2021.1946254 ↗
- Languages:
- English
- ISSNs:
- 1545-9624
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5026.080500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18506.xml