Investigation of isotropic radiation of low energy X-ray intra-operative radiotherapy by MAGAT gel dosimeter. (November 2021)
- Record Type:
- Journal Article
- Title:
- Investigation of isotropic radiation of low energy X-ray intra-operative radiotherapy by MAGAT gel dosimeter. (November 2021)
- Main Title:
- Investigation of isotropic radiation of low energy X-ray intra-operative radiotherapy by MAGAT gel dosimeter
- Authors:
- Alyani Nezhad, Zahra
Geraily, Ghazale
Zohari, Shahin - Abstract:
- Abstract: Purpose: Isotropy as a quality assurance aspect of intraoperative radiotherapy (IORT) needs to be evaluated accurately. There are some main problems associated with isotropy investigations by two dimensional dosimeters including limited positions and distances in which isotropy can be measured and long irradiation time needed for isotropy evaluation. In this study, isotropic radiation accuracy of spherical applicators of low energy X-ray IORT was estimated by the use of MAGAT gel as a three dimensional gel dosimeter and a specified IORT phantom. Methods: Designed IORT phantom was manufactured by multi-axis computer numerical control machine (CNC) using Plexiglas. To investigate isotropy, methacrylic acid, gelatin and tetrakis phosphonium chloride (MAGAT) gel dosimeters embedded in the phantom holes were irradiated with a 50 kV X-ray IORT device to 18 Gy at the surface of the vials. Then, relative dose deviations of output doses from their average were extracted from MRI images of the gel vials in different positions and distances from the 50-mm spherical applicator. Results: The percentages of relative deviations of output doses from the average value were less than 8% in all positions which are within the 15% acceptance limit of isotropy radiation. Moreover, a Pearson-moment correlation analysis showed a Pearson's r equal to 0.99–1 for different polar and azimuth angles representing isotropic radiation emission of X-ray IORT. Conclusion: Isotropy of IORT can beAbstract: Purpose: Isotropy as a quality assurance aspect of intraoperative radiotherapy (IORT) needs to be evaluated accurately. There are some main problems associated with isotropy investigations by two dimensional dosimeters including limited positions and distances in which isotropy can be measured and long irradiation time needed for isotropy evaluation. In this study, isotropic radiation accuracy of spherical applicators of low energy X-ray IORT was estimated by the use of MAGAT gel as a three dimensional gel dosimeter and a specified IORT phantom. Methods: Designed IORT phantom was manufactured by multi-axis computer numerical control machine (CNC) using Plexiglas. To investigate isotropy, methacrylic acid, gelatin and tetrakis phosphonium chloride (MAGAT) gel dosimeters embedded in the phantom holes were irradiated with a 50 kV X-ray IORT device to 18 Gy at the surface of the vials. Then, relative dose deviations of output doses from their average were extracted from MRI images of the gel vials in different positions and distances from the 50-mm spherical applicator. Results: The percentages of relative deviations of output doses from the average value were less than 8% in all positions which are within the 15% acceptance limit of isotropy radiation. Moreover, a Pearson-moment correlation analysis showed a Pearson's r equal to 0.99–1 for different polar and azimuth angles representing isotropic radiation emission of X-ray IORT. Conclusion: Isotropy of IORT can be easily investigated using gel dosimeters by applying the produced phantom which solved the issues facing three-dimensional measurement of isotropic radiation of IORT X-ray source (XRS). Highlights: Dose response of MAGAT is linear in different distances from X-ray IORT applicator. Specified IORT phantom made evaluation of isotropy feasible by gel dosimeters. Isotropy was investigated in various positions in shortened irradiation time. … (more)
- Is Part Of:
- Radiation physics and chemistry. Volume 188(2021)
- Journal:
- Radiation physics and chemistry
- Issue:
- Volume 188(2021)
- Issue Display:
- Volume 188, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 188
- Issue:
- 2021
- Issue Sort Value:
- 2021-0188-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-11
- Subjects:
- Intraoperative radiotherapy (IORT) -- Phantom -- Isotropy -- Gel dosimetry -- MAGAT
Radiation chemistry -- Periodicals
Radiometry -- Periodicals
Radiation -- Periodicals
Chimie sous rayonnement -- Périodiques
539.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0969806X ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-physics-and-chemistry/ ↗ - DOI:
- 10.1016/j.radphyschem.2021.109648 ↗
- Languages:
- English
- ISSNs:
- 0969-806X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.984000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18501.xml