Development and validation of an impedance biosensor for point-of-care detection of vascular cell adhesion molecule-1 toward lupus diagnostics. (7th July 2017)
- Record Type:
- Journal Article
- Title:
- Development and validation of an impedance biosensor for point-of-care detection of vascular cell adhesion molecule-1 toward lupus diagnostics. (7th July 2017)
- Main Title:
- Development and validation of an impedance biosensor for point-of-care detection of vascular cell adhesion molecule-1 toward lupus diagnostics
- Authors:
- Selvam, Anjan Panneer
Wangzhou, Andi
Jacobs, Michael
Wu, Tianfu
Mohan, Chandra
Prasad, Shalini - Abstract:
- Aim: Systemic lupus erythematosus is an autoimmune disease that requires chronic monitoring. In this study, we demonstrate a proof-of-concept study of a highly attractive noninvasive strategy for monitoring systemic lupus erythematosus through biomarker quantification.Results: This sensor technology requires 50 μl of urine to detect and quantify vascular cell adhesion molecule-1 in 15 min. The sensor used nonfaradaic detection to demonstrate performance with and without detection antibody. Binding of immunoassay and target biomarkers were quantified with an impedance electrical immunoassay and correlated with an equivalent circuit.Conclusion: The novel sensor technology demonstrates detection in the range of 8 fg/ml to 800 pg/ml and comparative analysis with ELISA platforms was performed for 12 patient urine samples. Lay abstract: A proof-of-concept portable biosensing system for rapid screening of systemic lupus erythematosus through the use of a biomarker has been demonstrated. This sensor is an electronic urine test, which screens for vascular cell adhesion molecule. The efficacy of the sensor has been validated using a small cohort of patient urine samples that have been evaluated using standard clinical methods. This biosensor is the first demonstration of a consumer-friendly point-of-care test suitable for home monitoring.
- Is Part Of:
- Future science OA. Volume 3:Number 3(2017)
- Journal:
- Future science OA
- Issue:
- Volume 3:Number 3(2017)
- Issue Display:
- Volume 3, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 3
- Issue:
- 3
- Issue Sort Value:
- 2017-0003-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-07-07
- Subjects:
- impedance biosensor -- rapid urine screening test -- VCAM-1
Medicine -- Periodicals
Biotechnology -- Periodicals
610 - Journal URLs:
- http://www.future-science.com/loi/fso ↗
http://www.future-science-group.com/ ↗ - DOI:
- 10.4155/fsoa-2017-0047 ↗
- Languages:
- English
- ISSNs:
- 2056-5623
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18486.xml