Jarragh, Ali - Abstract:
- Abstract: Introduction: Proximal humerus fractures are common amongst the elderly and osteoporotic cohorts. Common treatment methods include proximal locking plates. In this case, we describe an iatrogenic fracture of the proximal humeral shaft during screw insertion under power. Similar cases have not been described previously in open reduction and internal fixation of a proximal humerus fracture. Further, we focus particularly on precautionary measures that aim to avoid such complications that may lead to considerable morbidity. Case presentation: We describe a case of a 65 year old osteoporotic female who underwent open reduction internal fixation of a proximal humerus fracture complicated by an unusual iatrogenic humeral fracture at the level of insertion of the distal screw, likely secondary to inserting the proximal locking screws under power. Conclusion: In this case, we explore the possible factors leading to the fracture and precautionary measures to avoid them. The rate of iatrogenic intraoperative fractures are likely underreported and have not been described in open reduction and internal fixation of an existing fracture. The underlying factors that may predispose to such complications have not been previously described in similar cases. This case serves as a warning of an unanticipated complication and describes the potential biomechanical factors involved. Highlights: Proximal humerus fractures are common in the elderly and osteoporotic cohorts. IatrogenicAbstract: Introduction: Proximal humerus fractures are common amongst the elderly and osteoporotic cohorts. Common treatment methods include proximal locking plates. In this case, we describe an iatrogenic fracture of the proximal humeral shaft during screw insertion under power. Similar cases have not been described previously in open reduction and internal fixation of a proximal humerus fracture. Further, we focus particularly on precautionary measures that aim to avoid such complications that may lead to considerable morbidity. Case presentation: We describe a case of a 65 year old osteoporotic female who underwent open reduction internal fixation of a proximal humerus fracture complicated by an unusual iatrogenic humeral fracture at the level of insertion of the distal screw, likely secondary to inserting the proximal locking screws under power. Conclusion: In this case, we explore the possible factors leading to the fracture and precautionary measures to avoid them. The rate of iatrogenic intraoperative fractures are likely underreported and have not been described in open reduction and internal fixation of an existing fracture. The underlying factors that may predispose to such complications have not been previously described in similar cases. This case serves as a warning of an unanticipated complication and describes the potential biomechanical factors involved. Highlights: Proximal humerus fractures are common in the elderly and osteoporotic cohorts. Iatrogenic fractures intraoperatively during open reduction internal fixation have not been reported in orthopedic trauma. Care should be taken to avoid excessive energy/torque at screw sites while using electric drivers. The biomechanical precautions during fixation should be visited and more extensively described to avoid similar incidents. … (more)
- Is Part Of:
- Annals of medicine and surgery. Volume 68(2021)
- Journal:
- Annals of medicine and surgery
- Issue:
- Volume 68(2021)
- Issue Display:
- Volume 68, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 68
- Issue:
- 2021
- Issue Sort Value:
- 2021-0068-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08
- Subjects:
- Proximal humerus -- Iatrogenic fracture -- Complication -- Locking plate -- Torque
Surgery -- Periodicals
Medicine -- Periodicals
General Surgery -- Periodicals
Education, Medical -- Periodicals
Periodicals
617 - Journal URLs:
- http://www.sciencedirect.com/science/journal/20490801 ↗
http://bibpurl.oclc.org/web/73795 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/20490801 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/20490801 ↗
http://www.annalsjournal.com/home ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.amsu.2021.102615 ↗
- Languages:
- English
- ISSNs:
- 2049-0801
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18485.xml