Parameter co-design of active damping loop and grid current controller for a 3-phase LCL-filtered grid-connected inverter. (December 2021)
- Record Type:
- Journal Article
- Title:
- Parameter co-design of active damping loop and grid current controller for a 3-phase LCL-filtered grid-connected inverter. (December 2021)
- Main Title:
- Parameter co-design of active damping loop and grid current controller for a 3-phase LCL-filtered grid-connected inverter
- Authors:
- Lyu, Jianguo
Yan, Yiran
Wu, Fuyun
Sun, Zhuang
Farooq, Aamir
Xu, Weiji - Abstract:
- Highlights: Analyze the LCL grid-connected inverter in the discrete domain. The active damping loop with the grid-side currents feedback only. A co-design method of the active damping loop and current controller is proposed. Obtain the optimized parameters by introducing the Lagrange multiplier method. Abstract: Under non-ideal grid conditions, especially the harmonic grid condition, the proportional resonant controller with multiple harmonic resonant controllers (HR-PR controller) is recommended to provide high quality grid currents for the 3-phase LCL-filtered grid-connected inverter. Besides, in order to solve the resonance problem, the active damping loop with the grid-side currents feedback only is preferred. However, parameters of the HR-PR controller and the active damping loop both affect the performance of LCL filter resonance suppression and stability of the inverter, which is analyzed in this paper. Moreover, the stability constraint and the resonance suppression constraint is derived to maintain the good ability of LCL filter resonance suppression and satisfy the stability requirements of the inverter. Considering the wide control bandwidth for the HR-PR controller, a co-design method of the active damping loop and HR-PR controller is proposed in this paper. By introducing the Lagrange multiplier method, the proposed co-design method obtains the optimized parameters for the active damping loop and grid currents controller in z -domain appropriately. A prototypeHighlights: Analyze the LCL grid-connected inverter in the discrete domain. The active damping loop with the grid-side currents feedback only. A co-design method of the active damping loop and current controller is proposed. Obtain the optimized parameters by introducing the Lagrange multiplier method. Abstract: Under non-ideal grid conditions, especially the harmonic grid condition, the proportional resonant controller with multiple harmonic resonant controllers (HR-PR controller) is recommended to provide high quality grid currents for the 3-phase LCL-filtered grid-connected inverter. Besides, in order to solve the resonance problem, the active damping loop with the grid-side currents feedback only is preferred. However, parameters of the HR-PR controller and the active damping loop both affect the performance of LCL filter resonance suppression and stability of the inverter, which is analyzed in this paper. Moreover, the stability constraint and the resonance suppression constraint is derived to maintain the good ability of LCL filter resonance suppression and satisfy the stability requirements of the inverter. Considering the wide control bandwidth for the HR-PR controller, a co-design method of the active damping loop and HR-PR controller is proposed in this paper. By introducing the Lagrange multiplier method, the proposed co-design method obtains the optimized parameters for the active damping loop and grid currents controller in z -domain appropriately. A prototype of 3-phase LCL-filtered three-level neutral point clamped grid-connected inverter is established to validate the proposed method. … (more)
- Is Part Of:
- International journal of electrical power & energy systems. Volume 133(2021)
- Journal:
- International journal of electrical power & energy systems
- Issue:
- Volume 133(2021)
- Issue Display:
- Volume 133, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 133
- Issue:
- 2021
- Issue Sort Value:
- 2021-0133-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12
- Subjects:
- Active damping -- Grid-side current control -- Co-design -- LCL filter -- Stability -- Lagrange multiplier method
Electrical engineering -- Periodicals
Electric power systems -- Periodicals
Électrotechnique -- Périodiques
Réseaux électriques (Énergie) -- Périodiques
Electric power systems
Electrical engineering
Periodicals
621.3 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01420615 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijepes.2021.107203 ↗
- Languages:
- English
- ISSNs:
- 0142-0615
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.220000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18459.xml