Characterization of the mid-coronal plane method for measurement of radiographic change in knee joint space width across different levels of image parallax. Issue 9 (September 2021)
- Record Type:
- Journal Article
- Title:
- Characterization of the mid-coronal plane method for measurement of radiographic change in knee joint space width across different levels of image parallax. Issue 9 (September 2021)
- Main Title:
- Characterization of the mid-coronal plane method for measurement of radiographic change in knee joint space width across different levels of image parallax
- Authors:
- Chan, E.F.
Cockman, M.D.
Goel, P.
Newman, P.S.
Hipp, J.A. - Abstract:
- Summary: Objective: Radiographic measurement of the change in knee joint space width (ΔJSW) is often affected by image parallax, which causes an apparent exaggeration of JSW due to projectional differences. This issue with parallax (quantified by intermargin distance) can in part be addressed with a novel mid-coronal plane (MCP) measurement method. The objectives of the study were to determine 1) accuracy and 2) reproducibility of the MCP method, and 3) compare the MCP method to that used in the Osteoarthritis Initiative (OAI) for different categories of parallax. Methods: Posteroanterior radiographs ( n = 70) with known JSW were digitally reconstructed from CT images of cadaver knees and used to determine the accuracy of ΔJSW using the MCP method for parallax categories of None, Mild/Moderate, and Severe. Reproducibility was determined from pairs of clinical radiographs selected from the OAI ( n = 170). The MCP method was also compared to the OAI methodology. Both reproducibility and agreement were characterized by Bland-Altman analysis and intraclass correlation coefficients (ICC). Results: The MCP method was accurate to 0.11 mm in cases with no parallax, and 0.18 mm across all categories of parallax for medial and lateral compartments. Reproducibility of the MCP method was graded "excellent" (ICC 0.98, 95% CI [0.98, 0.99]). The MCP results agreed very well with the OAI (ICC 0.92, 95% CI [0.89, 0.94]), with mean absolute differences between methods increasing withSummary: Objective: Radiographic measurement of the change in knee joint space width (ΔJSW) is often affected by image parallax, which causes an apparent exaggeration of JSW due to projectional differences. This issue with parallax (quantified by intermargin distance) can in part be addressed with a novel mid-coronal plane (MCP) measurement method. The objectives of the study were to determine 1) accuracy and 2) reproducibility of the MCP method, and 3) compare the MCP method to that used in the Osteoarthritis Initiative (OAI) for different categories of parallax. Methods: Posteroanterior radiographs ( n = 70) with known JSW were digitally reconstructed from CT images of cadaver knees and used to determine the accuracy of ΔJSW using the MCP method for parallax categories of None, Mild/Moderate, and Severe. Reproducibility was determined from pairs of clinical radiographs selected from the OAI ( n = 170). The MCP method was also compared to the OAI methodology. Both reproducibility and agreement were characterized by Bland-Altman analysis and intraclass correlation coefficients (ICC). Results: The MCP method was accurate to 0.11 mm in cases with no parallax, and 0.18 mm across all categories of parallax for medial and lateral compartments. Reproducibility of the MCP method was graded "excellent" (ICC 0.98, 95% CI [0.98, 0.99]). The MCP results agreed very well with the OAI (ICC 0.92, 95% CI [0.89, 0.94]), with mean absolute differences between methods increasing with increasing parallax. Conclusion: The MCP method is an accurate, reproducible alternative to the OAI method for multi-center clinical trials where subject and X-ray beam positioning may be variable. … (more)
- Is Part Of:
- Osteoarthritis and cartilage. Volume 29:Issue 9(2021)
- Journal:
- Osteoarthritis and cartilage
- Issue:
- Volume 29:Issue 9(2021)
- Issue Display:
- Volume 29, Issue 9 (2021)
- Year:
- 2021
- Volume:
- 29
- Issue:
- 9
- Issue Sort Value:
- 2021-0029-0009-0000
- Page Start:
- 1306
- Page End:
- 1313
- Publication Date:
- 2021-09
- Subjects:
- Knee -- Joint space width -- Joint space narrowing -- Mid-coronal plane -- Inter-margin distance -- Parallax
Osteoarthritis -- Periodicals
Cartilage -- Periodicals
Osteoarthritis -- Periodicals
Cartilage -- Periodicals
Arthrose -- Périodiques
Articulations -- Maladies -- Périodiques
616.7223005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10634584 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10634584 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.joca.2021.06.006 ↗
- Languages:
- English
- ISSNs:
- 1063-4584
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6303.858870
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18468.xml