1412 Transcutaneous Bilirubinometers Used Within a Structured Pathway Predicts High Serum Bilirubin Levels in Healthy Term Jaundiced Neonates Monitored at Home. (October 2012)
- Record Type:
- Journal Article
- Title:
- 1412 Transcutaneous Bilirubinometers Used Within a Structured Pathway Predicts High Serum Bilirubin Levels in Healthy Term Jaundiced Neonates Monitored at Home. (October 2012)
- Main Title:
- 1412 Transcutaneous Bilirubinometers Used Within a Structured Pathway Predicts High Serum Bilirubin Levels in Healthy Term Jaundiced Neonates Monitored at Home
- Authors:
- Menakaya, JO
Davies, S
Callender, N - Abstract:
- Abstract : Background: UK (NICE) guidelines recommend that bilirubin is monitored in all jaundiced babies. We implemented a home based integrated care pathway to monitor healthy term jaundiced neonates with transcutaneous bilirubinometers (TcB). Babies were readmitted to hospital for phototherapy at total serum bilirubin (TsB) ≥340µmol/l. TcB ≤ 250µmol/l correlates highly with TsB. Aim: To determine the TcB values in term babies monitored at home that could predict TsB values ≥340µmol/l. Methods: Healthy jaundiced neonates were monitored at home using Bilichek ® (Ver 6.12) bilirubinometer. Babies with TcB > 250µmol/l had TsB measured using the Beckman Coulter timed endpoint diazo method within 4 hours to confirm result. We carried out statistical analysis of the paired samples to determine the TcB value with the best predictive value for TsB ≥ 340µmol/l. Results: Eighty-three paired samples were analysed from 63 babies. 6 (7%) had TsB values of ≥ 340µmol/l. The Receiver Operating Characteristics (ROC) curve analysis suggested an area under the curve (AUC) of 0.9037. TcB values ≥ 315µmol/l predicted TsB≥340 µmol/l with sensitivity of 0.83 (0.36, 1.00); specificity of 0.82 (0.71, 0.90); positive predictive value of 0.26 (0.09, 0.51) and overall accuracy of 0.82 (0.72, 0.90). TcB values ≥ 303µmol/l predictive ability had a sensitivity of 1.00 (0.54, 1.00); specificity of 0.71 (0.60, 0.81), positive predictive value of 0.21 (0.08, 0.41) and overall accuracy 0.73 (0.63, 0.83).Abstract : Background: UK (NICE) guidelines recommend that bilirubin is monitored in all jaundiced babies. We implemented a home based integrated care pathway to monitor healthy term jaundiced neonates with transcutaneous bilirubinometers (TcB). Babies were readmitted to hospital for phototherapy at total serum bilirubin (TsB) ≥340µmol/l. TcB ≤ 250µmol/l correlates highly with TsB. Aim: To determine the TcB values in term babies monitored at home that could predict TsB values ≥340µmol/l. Methods: Healthy jaundiced neonates were monitored at home using Bilichek ® (Ver 6.12) bilirubinometer. Babies with TcB > 250µmol/l had TsB measured using the Beckman Coulter timed endpoint diazo method within 4 hours to confirm result. We carried out statistical analysis of the paired samples to determine the TcB value with the best predictive value for TsB ≥ 340µmol/l. Results: Eighty-three paired samples were analysed from 63 babies. 6 (7%) had TsB values of ≥ 340µmol/l. The Receiver Operating Characteristics (ROC) curve analysis suggested an area under the curve (AUC) of 0.9037. TcB values ≥ 315µmol/l predicted TsB≥340 µmol/l with sensitivity of 0.83 (0.36, 1.00); specificity of 0.82 (0.71, 0.90); positive predictive value of 0.26 (0.09, 0.51) and overall accuracy of 0.82 (0.72, 0.90). TcB values ≥ 303µmol/l predictive ability had a sensitivity of 1.00 (0.54, 1.00); specificity of 0.71 (0.60, 0.81), positive predictive value of 0.21 (0.08, 0.41) and overall accuracy 0.73 (0.63, 0.83). Conclusion: Bilichek ® TcB of 303µmol/l had higher sensitivity but lower specificity than TcB of 315µmol/l for predicting TsB values ≥ 340µmol/l in healthy term jaundiced neonates monitored at home. … (more)
- Is Part Of:
- Archives of disease in childhood. Volume 97(2012)Supplement 2
- Journal:
- Archives of disease in childhood
- Issue:
- Volume 97(2012)Supplement 2
- Issue Display:
- Volume 97, Issue 2 (2012)
- Year:
- 2012
- Volume:
- 97
- Issue:
- 2
- Issue Sort Value:
- 2012-0097-0002-0000
- Page Start:
- A402
- Page End:
- A402
- Publication Date:
- 2012-10
- Subjects:
- Children -- Diseases -- Periodicals
Infants -- Diseases -- Periodicals
618.920005 - Journal URLs:
- http://adc.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/archdischild-2012-302724.1412 ↗
- Languages:
- English
- ISSNs:
- 0003-9888
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18427.xml