Diagnostic accuracy of automated occlusion detection in CT angiography using e-CTA. Issue 1 (January 2022)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of automated occlusion detection in CT angiography using e-CTA. Issue 1 (January 2022)
- Main Title:
- Diagnostic accuracy of automated occlusion detection in CT angiography using e-CTA
- Authors:
- Seker, Fatih
Pfaff, Johannes Alex Rolf
Mokli, Yahia
Berberich, Anne
Namias, Rafael
Gerry, Steven
Nagel, Simon
Bendszus, Martin
Herweh, Christian - Abstract:
- Background and aim: The aim of this study was to assess the diagnostic accuracy of e-CTA (product name) (Brainomix) in the automatic detection of large vessel occlusions in anterior circulation stroke. Methods: Of 487 CT angiographies from patients with large vessel occlusions stroke, 327 were used to train the algorithm while the remaining cases together with 140 negative CT angiographies were used to validate its performance against ground truth. Of these 301 cases, 144 were randomly selected and used for an additional comparative analysis against 4 raters. Sensitivity, specificity, positive and negative predictive value (PPV and NPV), accuracy and level of agreement with ground truth (Cohen's Kappa) were determined and compared to the performance of a neuroradiologist, a radiology resident, and two neurology residents. Results: e-CTA had a sensitivity and specificity of 0.84 (0.77–0.89) and 0.96 (0.91–0.98) respectively for the detection of any large vessel occlusions on the correct side in the whole validation cohort. This performance was identical in the comparative analysis subgroup and was within the range of physicians at different levels of expertise: 0.86–0.97 and 0.91–1.00, respectively. For the detection of proximal occlusions, it was 0.92 (0.84–0.96) and 0.98 (0.94–1.00) for the whole cohort and 0.93 (0.80–0.98) and 1.00 (0.95–1.00) for the comparative analysis, respectively for e-CTA. The range was 0.8–0.97 for sensitivity and 0.97–1.00 for specificity for theBackground and aim: The aim of this study was to assess the diagnostic accuracy of e-CTA (product name) (Brainomix) in the automatic detection of large vessel occlusions in anterior circulation stroke. Methods: Of 487 CT angiographies from patients with large vessel occlusions stroke, 327 were used to train the algorithm while the remaining cases together with 140 negative CT angiographies were used to validate its performance against ground truth. Of these 301 cases, 144 were randomly selected and used for an additional comparative analysis against 4 raters. Sensitivity, specificity, positive and negative predictive value (PPV and NPV), accuracy and level of agreement with ground truth (Cohen's Kappa) were determined and compared to the performance of a neuroradiologist, a radiology resident, and two neurology residents. Results: e-CTA had a sensitivity and specificity of 0.84 (0.77–0.89) and 0.96 (0.91–0.98) respectively for the detection of any large vessel occlusions on the correct side in the whole validation cohort. This performance was identical in the comparative analysis subgroup and was within the range of physicians at different levels of expertise: 0.86–0.97 and 0.91–1.00, respectively. For the detection of proximal occlusions, it was 0.92 (0.84–0.96) and 0.98 (0.94–1.00) for the whole cohort and 0.93 (0.80–0.98) and 1.00 (0.95–1.00) for the comparative analysis, respectively for e-CTA. The range was 0.8–0.97 for sensitivity and 0.97–1.00 for specificity for the four physicians. Conclusions: The performance of e-CTA in detecting any large vessel occlusions is comparable to less experienced physicians but is similar to experienced physicians for detecting proximal large vessel occlusions. … (more)
- Is Part Of:
- International journal of stroke. Volume 17:Issue 1(2022)
- Journal:
- International journal of stroke
- Issue:
- Volume 17:Issue 1(2022)
- Issue Display:
- Volume 17, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 17
- Issue:
- 1
- Issue Sort Value:
- 2022-0017-0001-0000
- Page Start:
- 77
- Page End:
- 82
- Publication Date:
- 2022-01
- Subjects:
- Artificial intelligence -- CT angiography -- CT scan -- ischemic stroke -- large vessel occlusion -- radiology
616.8005 - Journal URLs:
- http://wso.sagepub.com/ ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=ijs ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1177/1747493021992592 ↗
- Languages:
- English
- ISSNs:
- 1747-4930
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.681485
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18429.xml