How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin?. Issue 3 (11th August 2017)
- Record Type:
- Journal Article
- Title:
- How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin?. Issue 3 (11th August 2017)
- Main Title:
- How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin?
- Authors:
- Tracy, Mark Brian
Priyadarshi, Archana
Goel, Dimple
Lowe, Krista
Huvanandana, Jacqueline
Hinder, Murray - Abstract:
- Abstract : Background: International neonatal resuscitation guidelines recommend the use of laryngeal mask airway (LMA) with newborn infants (≥34 weeks' gestation or >2 kg weight) when bag-mask ventilation (BMV) or tracheal intubation is unsuccessful. Previous publications do not allow broad LMA device comparison. Objective: To compare delivered ventilation of seven brands of size 1 LMA devices with two brands of face mask using self-inflating bag (SIB). Design: 40 experienced neonatal staff provided inflation cycles using SIB with positive end expiratory pressure (PEEP) (5 cmH2 O) to a specialised newborn/infant training manikin randomised for each LMA and face mask. All subjects received prior education in LMA insertion and BMV. Results: 12 415 recorded inflations for LMAs and face masks were analysed. Leak detected was lowest with i-gel brand, with a mean of 5.7% compared with face mask (triangular 42.7, round 35.7) and other LMAs (45.5–65.4) (p<0.001). Peak inspiratory pressure was higher with i-gel, with a mean of 28.9 cmH2 O compared with face mask (triangular 22.8, round 25.8) and other LMAs (14.3–22.0) (p<0.001). PEEP was higher with i-gel, with a mean of 5.1 cmH2 O compared with face mask (triangular 3.0, round 3.6) and other LMAs (0.6–2.6) (p<0.001). In contrast to other LMAs examined, i-gel had no insertion failures and all users found i-gel easy to use. Conclusion: This study has shown dramatic performance differences in delivered ventilation, mask leak and easeAbstract : Background: International neonatal resuscitation guidelines recommend the use of laryngeal mask airway (LMA) with newborn infants (≥34 weeks' gestation or >2 kg weight) when bag-mask ventilation (BMV) or tracheal intubation is unsuccessful. Previous publications do not allow broad LMA device comparison. Objective: To compare delivered ventilation of seven brands of size 1 LMA devices with two brands of face mask using self-inflating bag (SIB). Design: 40 experienced neonatal staff provided inflation cycles using SIB with positive end expiratory pressure (PEEP) (5 cmH2 O) to a specialised newborn/infant training manikin randomised for each LMA and face mask. All subjects received prior education in LMA insertion and BMV. Results: 12 415 recorded inflations for LMAs and face masks were analysed. Leak detected was lowest with i-gel brand, with a mean of 5.7% compared with face mask (triangular 42.7, round 35.7) and other LMAs (45.5–65.4) (p<0.001). Peak inspiratory pressure was higher with i-gel, with a mean of 28.9 cmH2 O compared with face mask (triangular 22.8, round 25.8) and other LMAs (14.3–22.0) (p<0.001). PEEP was higher with i-gel, with a mean of 5.1 cmH2 O compared with face mask (triangular 3.0, round 3.6) and other LMAs (0.6–2.6) (p<0.001). In contrast to other LMAs examined, i-gel had no insertion failures and all users found i-gel easy to use. Conclusion: This study has shown dramatic performance differences in delivered ventilation, mask leak and ease of use among seven different brands of LMA tested in a manikin model. This coupled with no partial or complete insertion failures and ease of use suggests i-gel LMA may have an expanded role with newborn resuscitation as a primary resuscitation device. … (more)
- Is Part Of:
- Archives of disease in childhood. Volume 103:Issue 3(2018)
- Journal:
- Archives of disease in childhood
- Issue:
- Volume 103:Issue 3(2018)
- Issue Display:
- Volume 103, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 103
- Issue:
- 3
- Issue Sort Value:
- 2018-0103-0003-0000
- Page Start:
- F271
- Page End:
- F276
- Publication Date:
- 2017-08-11
- Subjects:
- newborn -- resuscitation -- laryngeal mask airway -- self inflating bag -- manikin
Infants -- Diseases -- Periodicals
Newborn infants -- Diseases -- Periodicals
Fetus -- Diseases -- Periodicals
618.920105 - Journal URLs:
- http://fn.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/archdischild-2017-312766 ↗
- Languages:
- English
- ISSNs:
- 1359-2998
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18427.xml