An Emerging Method to Assess Tear Film Spread and Dynamics as Possible Tear Film Homeostasis Markers. (2nd September 2021)
- Record Type:
- Journal Article
- Title:
- An Emerging Method to Assess Tear Film Spread and Dynamics as Possible Tear Film Homeostasis Markers. (2nd September 2021)
- Main Title:
- An Emerging Method to Assess Tear Film Spread and Dynamics as Possible Tear Film Homeostasis Markers
- Authors:
- García-Marqués, José Vicente
Talens-Estarelles, Cristian
Martínez-Albert, Noelia
García-Lázaro, Santiago
Cerviño, Alejandro - Abstract:
- ABSTRACT: Purpose : This study aims to assess the performance of an analysis method to measure in vivo the movement speed of tear film particles post-blink as a measure of tear film spreading. Materials and methods : Ocular surface parameters and the recording of tear film particles' spreading post-blink were assessed in eighty-one healthy volunteers (43.7 ± 27.0 years) using Keratograph 5 M. The developed software automatically decomposed the video into frames to manually track particles' position for 1.75 seconds after a blink. The following tear film-dynamic metrics were automatically calculated: mean, median, maximum, and minimum particles' speed at different times after blinking and time for particle speed to decrease to <1.20 mm/second. Repeatability of each tear film-dynamic metric and its correlations with ocular surface signs and symptoms were analyzed. Binomial logistic regression was performed to assess the predictability of new metrics to ocular parameters. Results : Repeatability tended to be lower just after blinking (variability of 12.24%), whereas the metrics from 0.5 s onwards had acceptable repeatability (variability below 10%). Tear film-dynamic metrics correlated positively with Non-Invasive Break-Up Time (NIKBUT) while negatively with meibomian gland drop-out. Binomial logistic regression analysis revealed that tear film-dynamic metrics were able to predict NIKBUT. Nevertheless, no statistically significant association was found with gland drop-out. ThisABSTRACT: Purpose : This study aims to assess the performance of an analysis method to measure in vivo the movement speed of tear film particles post-blink as a measure of tear film spreading. Materials and methods : Ocular surface parameters and the recording of tear film particles' spreading post-blink were assessed in eighty-one healthy volunteers (43.7 ± 27.0 years) using Keratograph 5 M. The developed software automatically decomposed the video into frames to manually track particles' position for 1.75 seconds after a blink. The following tear film-dynamic metrics were automatically calculated: mean, median, maximum, and minimum particles' speed at different times after blinking and time for particle speed to decrease to <1.20 mm/second. Repeatability of each tear film-dynamic metric and its correlations with ocular surface signs and symptoms were analyzed. Binomial logistic regression was performed to assess the predictability of new metrics to ocular parameters. Results : Repeatability tended to be lower just after blinking (variability of 12.24%), whereas the metrics from 0.5 s onwards had acceptable repeatability (variability below 10%). Tear film-dynamic metrics correlated positively with Non-Invasive Break-Up Time (NIKBUT) while negatively with meibomian gland drop-out. Binomial logistic regression analysis revealed that tear film-dynamic metrics were able to predict NIKBUT. Nevertheless, no statistically significant association was found with gland drop-out. This means that higher particle speed is related to larger NIKBUT. The metric "time for particle speed to decrease to <1.20 mm/second" can be considered the best metric to assess the quality of the tear film, since it was more strongly correlated with NIKBUT (r = 0.42, p = .004), it was more strongly associated in the binomial logistic regression analysis with NIKBUT and showed good repeatability (variability = 5.49%). Conclusions : Tear film-dynamic metrics are emerging homeostasis parameters for assessing indirectly the tear film quality in natural conditions with acceptable repeatability. … (more)
- Is Part Of:
- Current eye research. Volume 46:Number 9(2021)
- Journal:
- Current eye research
- Issue:
- Volume 46:Number 9(2021)
- Issue Display:
- Volume 46, Issue 9 (2021)
- Year:
- 2021
- Volume:
- 46
- Issue:
- 9
- Issue Sort Value:
- 2021-0046-0009-0000
- Page Start:
- 1291
- Page End:
- 1298
- Publication Date:
- 2021-09-02
- Subjects:
- Dry Eye -- objective medical image analysis -- tear film -- tear hydrodynamics -- tear film homeostasis
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
Ophthalmology -- Periodicals
573.88 - Journal URLs:
- http://informahealthcare.com/journal/cey ↗
http://www.tandfonline.com/toc/icey20/current ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02713683.2021.1887270 ↗
- Languages:
- English
- ISSNs:
- 0271-3683
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3496.570000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18407.xml