Supra-Annular Sizing for Prediction of THV Expansion in Bicuspid Aortic Valves: A MSCT Study. Issue 4 (4th July 2021)
- Record Type:
- Journal Article
- Title:
- Supra-Annular Sizing for Prediction of THV Expansion in Bicuspid Aortic Valves: A MSCT Study. Issue 4 (4th July 2021)
- Main Title:
- Supra-Annular Sizing for Prediction of THV Expansion in Bicuspid Aortic Valves: A MSCT Study
- Authors:
- De Biase, Chiara
Agudze, Edem
Siddiqui, Saifullah
Agudze, Komla
Ghattas, Angie
Laperche, Clemence
Dubois, Daniela
Philippart, Raphael
Monteil, Benoit
Dumonteil, Nicolas
Tchetche, Didier - Abstract:
- ABSTRACT: Background: Multislice computed tomography (MSCT) is the most common sizing method for transcatheter aortic valve implantation (TAVI) in the bicuspid aortic valve (BAV). It is unclear whether annular and supra-annular dimensions could predict final prosthesis diameter and expansion. This study aimed to identify baseline MSCT measurement that could predict the geometry of the transcatheter heart valve (THV) in BAV patients undergoing TAVI for symptomatic aortic stenosis (AS). Methods: One hundred and two BAV patients undergoing TAVI for AS were included in this observational, retrospective, single-center study. Pre- and post-TAVI MSCT were compared. On pre and post MSCT, means of perimeter-derived diameter (PdD) and ellipticity indexes were measured at the annular plane and 4 mm and 8 mm above, and intercommissural distance (ICD) at 4 and 8 mm. Results: Comparison of pre- and post-TAVI PdDs at 3 levels showed that pre-TAVI PdD at +4 mm was comparable to post-TAVI PdD at annulus (24.2 ± 2.6 mm vs. 24.0 ± 2.7 mm; p = 0.87; mean difference: 0.04; SD: 2.54; 95% CI: −0.46; 0.54) and at +4 mm (24.2 ± 2.6 mm vs. 23.7 ± 2.5 mm; p = 0.16; mean difference: 0.36; SD: 2.60; 95% CI: −0.15; 0.87). All other comparisons showed significant difference between pre and post dimensions, with reduction in post-TAVI THV dimensions, as compared to baseline measurements, suggesting underexpansion. Pre- and post-TAVI ellipticity indexes comparison showed significant reduction in post-TAVIABSTRACT: Background: Multislice computed tomography (MSCT) is the most common sizing method for transcatheter aortic valve implantation (TAVI) in the bicuspid aortic valve (BAV). It is unclear whether annular and supra-annular dimensions could predict final prosthesis diameter and expansion. This study aimed to identify baseline MSCT measurement that could predict the geometry of the transcatheter heart valve (THV) in BAV patients undergoing TAVI for symptomatic aortic stenosis (AS). Methods: One hundred and two BAV patients undergoing TAVI for AS were included in this observational, retrospective, single-center study. Pre- and post-TAVI MSCT were compared. On pre and post MSCT, means of perimeter-derived diameter (PdD) and ellipticity indexes were measured at the annular plane and 4 mm and 8 mm above, and intercommissural distance (ICD) at 4 and 8 mm. Results: Comparison of pre- and post-TAVI PdDs at 3 levels showed that pre-TAVI PdD at +4 mm was comparable to post-TAVI PdD at annulus (24.2 ± 2.6 mm vs. 24.0 ± 2.7 mm; p = 0.87; mean difference: 0.04; SD: 2.54; 95% CI: −0.46; 0.54) and at +4 mm (24.2 ± 2.6 mm vs. 23.7 ± 2.5 mm; p = 0.16; mean difference: 0.36; SD: 2.60; 95% CI: −0.15; 0.87). All other comparisons showed significant difference between pre and post dimensions, with reduction in post-TAVI THV dimensions, as compared to baseline measurements, suggesting underexpansion. Pre- and post-TAVI ellipticity indexes comparison showed significant reduction in post-TAVI ellipticity indexes at 3 levels, suggesting a more circular THV geometry. Conclusion: In BAV, supra-annular PdD at 4 mm was comparable to post-TAVI THV PdDs. THV underexpansion and anatomical reshaping occurred after TAVI in BAV. Abbreviations: AS, aortic stenosis; BAV, bicuspid aortic valve; ICD, intercommissural distance; MSCT, multislice computed tomography; PdD, perimeter-derived diameter; STS, Society of Thoracic Surgeons score; TAVI, transcatheter aortic valve implantation; THV, transcatheter heart valve. … (more)
- Is Part Of:
- Structural heart. Volume 5:Issue 4(2021)
- Journal:
- Structural heart
- Issue:
- Volume 5:Issue 4(2021)
- Issue Display:
- Volume 5, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 5
- Issue:
- 4
- Issue Sort Value:
- 2021-0005-0004-0000
- Page Start:
- 382
- Page End:
- 391
- Publication Date:
- 2021-07-04
- Subjects:
- Bicuspid aortic valve (BAV) -- multislice computed tomography (MSCT) -- transcatheter heart valve (THV) -- transcatheter aortic valve implantation (TAVI)
Heart -- Diseases -- Periodicals
Congenital heart disease -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cardiovascular Diseases
Cardiovascular system -- Diseases
Congenital heart disease
Heart -- Diseases
Periodicals
616.12 - Journal URLs:
- http://www.tandfonline.com/loi/ushj20 ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/24748706.2021.1915515 ↗
- Languages:
- English
- ISSNs:
- 2474-8706
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18415.xml