Influence of hemolysis on serum procalcitonin measured by electrochemiluminescence in an emergency room. Issue 30 (13th July 2021)
- Record Type:
- Journal Article
- Title:
- Influence of hemolysis on serum procalcitonin measured by electrochemiluminescence in an emergency room. Issue 30 (13th July 2021)
- Main Title:
- Influence of hemolysis on serum procalcitonin measured by electrochemiluminescence in an emergency room
- Authors:
- Liu, Chong
Peng, Ziyuan
Cui, Liyan
Wang, Tiancheng
Wu, Yonghua - Abstract:
- Abstract : To investigate the effect of hemolysis on serum procalcitonin (PCT) detected by electrochemiluminescence (ECL) and to explore the possibility of establishment of a correction equation. Abstract : Background: To investigate the effect of hemolysis on serum procalcitonin (PCT) detected by electrochemiluminescence (ECL) and to explore the possibility of establishment of a correction equation. Methods: Fifty-one blood samples from 17 patients were collected. Hemolytic samples, of which the final concentrations of hemoglobin (Hb) were 5, 10, 15 and 20 g L −1, were prepared by adding lysed homologous RBCs to serum, and then the PCT levels were detected and compared. Results: with the increasing degree of sample hemolysis, PCT bias elevated from −13.12% to −38.86% as the hemolysis degree increased from 5 g L −1 to 20 g L −1, respectively. There was a linear correlation of PCT levels between the original and hemolytic samples with the same hemolytic degree ( r > 0.97). Using the correction equation log10 PCTcorr = 0.962(log10 PCThemo ) +0.251(log10 Hb) − 0.126, the corrected PCT values from the hemolytic samples showed acceptable consistency with the original values ( p > 0.05). Conclusions: Hemolysis has a negative interference on PCT values assayed by ECL. The serum PCT level is correlated negatively with the Hb level in the blood sample. The established correction equation could reduce inappropriate antibiotics application and improve the experience of patients in theAbstract : To investigate the effect of hemolysis on serum procalcitonin (PCT) detected by electrochemiluminescence (ECL) and to explore the possibility of establishment of a correction equation. Abstract : Background: To investigate the effect of hemolysis on serum procalcitonin (PCT) detected by electrochemiluminescence (ECL) and to explore the possibility of establishment of a correction equation. Methods: Fifty-one blood samples from 17 patients were collected. Hemolytic samples, of which the final concentrations of hemoglobin (Hb) were 5, 10, 15 and 20 g L −1, were prepared by adding lysed homologous RBCs to serum, and then the PCT levels were detected and compared. Results: with the increasing degree of sample hemolysis, PCT bias elevated from −13.12% to −38.86% as the hemolysis degree increased from 5 g L −1 to 20 g L −1, respectively. There was a linear correlation of PCT levels between the original and hemolytic samples with the same hemolytic degree ( r > 0.97). Using the correction equation log10 PCTcorr = 0.962(log10 PCThemo ) +0.251(log10 Hb) − 0.126, the corrected PCT values from the hemolytic samples showed acceptable consistency with the original values ( p > 0.05). Conclusions: Hemolysis has a negative interference on PCT values assayed by ECL. The serum PCT level is correlated negatively with the Hb level in the blood sample. The established correction equation could reduce inappropriate antibiotics application and improve the experience of patients in the emergency department. … (more)
- Is Part Of:
- Analytical methods. Volume 13:Issue 30(2021)
- Journal:
- Analytical methods
- Issue:
- Volume 13:Issue 30(2021)
- Issue Display:
- Volume 13, Issue 30 (2021)
- Year:
- 2021
- Volume:
- 13
- Issue:
- 30
- Issue Sort Value:
- 2021-0013-0030-0000
- Page Start:
- 3410
- Page End:
- 3413
- Publication Date:
- 2021-07-13
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d1ay00442e ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18404.xml