Risk of ventricular arrhythmia in cardiac resynchronization therapy responders and super-responders: a systematic review and meta-analysis. Issue 8 (26th January 2021)
- Record Type:
- Journal Article
- Title:
- Risk of ventricular arrhythmia in cardiac resynchronization therapy responders and super-responders: a systematic review and meta-analysis. Issue 8 (26th January 2021)
- Main Title:
- Risk of ventricular arrhythmia in cardiac resynchronization therapy responders and super-responders: a systematic review and meta-analysis
- Authors:
- Yuyun, Matthew F
Erqou, Sebhat A
Peralta, Adelqui O
Hoffmeister, Peter S
Yarmohammadi, Hirad
Echouffo Tcheugui, Justin B
Martin, David T
Joseph, Jacob
Singh, Jagmeet P - Abstract:
- Abstract: Aims: Response to cardiac resynchronization therapy (CRT) is associated with improved survival, and reduction in heart failure hospitalization, and ventricular arrhythmia (VA) risk. However, the impact of CRT super-response [CRT-SR, increase in left ventricular ejection fraction (LVEF) to ≥ 50%] on VA remains unclear. Methods and results: We undertook a meta-analysis aimed at determining the impact of CRT response and CRT-SR on risk of VA and all-cause mortality. Systematic search of PubMed, EMBASE, and Cochrane databases, identifying all relevant English articles published until 31 December 2019. A total of 34 studies (7605 patients for VA and 5874 patients for all-cause mortality) were retained for the meta-analysis. The pooled cumulative incidence of appropriate implantable cardioverter-defibrillator therapy for VA was significantly lower at 13.0% (4.5% per annum) in CRT-responders, vs. 29.0% (annualized rate of 10.0%) in CRT non-responders, relative risk (RR) 0.47 [95% confidence interval (CI) 0.39–0.56, P < 0.0001]; all-cause mortality 3.5% vs. 9.1% per annum, RR of 0.38 (95% CI 0.30–0.49, P < 0.0001). The pooled incidence of VA was significantly lower in CRT-SR compared with CRT non-super-responders (non-responders + responders) at 0.9% vs. 3.8% per annum, respectively, RR 0.22 (95% CI 0.12–0.40, P < 0.0001); as well as all-cause mortality at 2.0% vs. 4.3%, respectively, RR 0.47 (95% CI 0.33–0.66, P < 0.0001). Conclusions: Cardiac resynchronizationAbstract: Aims: Response to cardiac resynchronization therapy (CRT) is associated with improved survival, and reduction in heart failure hospitalization, and ventricular arrhythmia (VA) risk. However, the impact of CRT super-response [CRT-SR, increase in left ventricular ejection fraction (LVEF) to ≥ 50%] on VA remains unclear. Methods and results: We undertook a meta-analysis aimed at determining the impact of CRT response and CRT-SR on risk of VA and all-cause mortality. Systematic search of PubMed, EMBASE, and Cochrane databases, identifying all relevant English articles published until 31 December 2019. A total of 34 studies (7605 patients for VA and 5874 patients for all-cause mortality) were retained for the meta-analysis. The pooled cumulative incidence of appropriate implantable cardioverter-defibrillator therapy for VA was significantly lower at 13.0% (4.5% per annum) in CRT-responders, vs. 29.0% (annualized rate of 10.0%) in CRT non-responders, relative risk (RR) 0.47 [95% confidence interval (CI) 0.39–0.56, P < 0.0001]; all-cause mortality 3.5% vs. 9.1% per annum, RR of 0.38 (95% CI 0.30–0.49, P < 0.0001). The pooled incidence of VA was significantly lower in CRT-SR compared with CRT non-super-responders (non-responders + responders) at 0.9% vs. 3.8% per annum, respectively, RR 0.22 (95% CI 0.12–0.40, P < 0.0001); as well as all-cause mortality at 2.0% vs. 4.3%, respectively, RR 0.47 (95% CI 0.33–0.66, P < 0.0001). Conclusions: Cardiac resynchronization therapy super-responders have low absolute risk of VA and all-cause mortality. However, there remains a non-trivial residual absolute risk of these adverse outcomes in CRT responders. These findings suggest that among CRT responders, there may be a continued clinical benefit of defibrillators. … (more)
- Is Part Of:
- Europace. Volume 23:Issue 8(2021)
- Journal:
- Europace
- Issue:
- Volume 23:Issue 8(2021)
- Issue Display:
- Volume 23, Issue 8 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 8
- Issue Sort Value:
- 2021-0023-0008-0000
- Page Start:
- 1262
- Page End:
- 1274
- Publication Date:
- 2021-01-26
- Subjects:
- Cardiac resynchronization therapy -- Responders -- Super responders -- Implantable cardioverter-defibrillator -- Heart failure -- Left ventricular ejection fraction -- Ventricular arrhythmia -- Mortality -- Meta-analysis
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa414 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18418.xml