Fixation of Unstable Osteochondritis Dissecans Lesions and Displaced Osteochondral Fragments Using New Biodegradable Magnesium Pins in Adolescents. (December 2021)
- Record Type:
- Journal Article
- Title:
- Fixation of Unstable Osteochondritis Dissecans Lesions and Displaced Osteochondral Fragments Using New Biodegradable Magnesium Pins in Adolescents. (December 2021)
- Main Title:
- Fixation of Unstable Osteochondritis Dissecans Lesions and Displaced Osteochondral Fragments Using New Biodegradable Magnesium Pins in Adolescents
- Authors:
- Jungesblut, Oliver D.
Moritz, Menard
Spiro, Alexander S.
Stuecker, Ralf
Rupprecht, Martin - Abstract:
- Objective: Fixation of unstable osteochondritis dissecans (OCD) lesions and displaced osteochondral fragments are frequently performed procedures in pediatric orthopedic surgery. Since 2018, CE-certified MAGNEZIX pins are used in our institution in these cases. The aim of this study was (1) to analyze safety, efficiency, and limitations of magnesium-pin-based fixation of unstable OCD lesions and displaced osteochondral fragments and (2) to report clinical and radiological outcomes at short-term follow-up (FU). Design: In this prospective cohort study, 19 patients (10 girls and 9 boys) were included. Inclusion criteria were (1) magnetic resonance imaging–confirmed unstable OCD lesion or displaced osteochondral fragment, (2) fixation with magnesium-based pins, and (3) minimum FU of 6 months. X-rays were taken 6 weeks and 6 months after operation and magnetic resonance imaging scans every 4 to 6 months to assess the healing progress. Results: In total 67 pins were used, with a mean of 3.6 ± 1.4 per patient. Average age at surgery was 13.7 years (11-17 years). Mean time of operation was 56 ± 31 minutes, including arthroscopy, fixation, and patellar realignment ( n = 6). No intraoperative complications occurred. Average FU was 11.3 ± 4.2 months (6-20 months). No redislocation or new dislocation occurred. Until now a complete radiographic healing occurred in 12 cases. Due to an implant failure in one case 11 weeks after the index surgery a revision became necessary. Conclusions:Objective: Fixation of unstable osteochondritis dissecans (OCD) lesions and displaced osteochondral fragments are frequently performed procedures in pediatric orthopedic surgery. Since 2018, CE-certified MAGNEZIX pins are used in our institution in these cases. The aim of this study was (1) to analyze safety, efficiency, and limitations of magnesium-pin-based fixation of unstable OCD lesions and displaced osteochondral fragments and (2) to report clinical and radiological outcomes at short-term follow-up (FU). Design: In this prospective cohort study, 19 patients (10 girls and 9 boys) were included. Inclusion criteria were (1) magnetic resonance imaging–confirmed unstable OCD lesion or displaced osteochondral fragment, (2) fixation with magnesium-based pins, and (3) minimum FU of 6 months. X-rays were taken 6 weeks and 6 months after operation and magnetic resonance imaging scans every 4 to 6 months to assess the healing progress. Results: In total 67 pins were used, with a mean of 3.6 ± 1.4 per patient. Average age at surgery was 13.7 years (11-17 years). Mean time of operation was 56 ± 31 minutes, including arthroscopy, fixation, and patellar realignment ( n = 6). No intraoperative complications occurred. Average FU was 11.3 ± 4.2 months (6-20 months). No redislocation or new dislocation occurred. Until now a complete radiographic healing occurred in 12 cases. Due to an implant failure in one case 11 weeks after the index surgery a revision became necessary. Conclusions: In short-term FU of 11 ± 4 months MAGNEZIX pins provide high stability after fixation of unstable OCDs and displaced osteochondral fragments leading to uncomplicated and timely healing. … (more)
- Is Part Of:
- Cartilage. Volume 13:Number 1(2022)Supplement
- Journal:
- Cartilage
- Issue:
- Volume 13:Number 1(2022)Supplement
- Issue Display:
- Volume 13, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 13
- Issue:
- 1
- Issue Sort Value:
- 2022-0013-0001-0000
- Page Start:
- 302S
- Page End:
- 310S
- Publication Date:
- 2021-12
- Subjects:
- biodegradable implants -- magnesium pins -- osteochondritis dissecans -- osteochondral lesion
Cartilage -- Periodicals
616.7 - Journal URLs:
- http://car.sagepub.com/ ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1947603520942943 ↗
- Languages:
- English
- ISSNs:
- 1947-6035
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18387.xml