A novel food-based foam as oral contrast agent with negative Hounsfield units for demarcation of small bowel loops on abdominal CT: tolerability and bowel distension in 25 volunteers. (December 2021)
- Record Type:
- Journal Article
- Title:
- A novel food-based foam as oral contrast agent with negative Hounsfield units for demarcation of small bowel loops on abdominal CT: tolerability and bowel distension in 25 volunteers. (December 2021)
- Main Title:
- A novel food-based foam as oral contrast agent with negative Hounsfield units for demarcation of small bowel loops on abdominal CT: tolerability and bowel distension in 25 volunteers
- Authors:
- Leander, Peter
Adnerhill, Ingvar
Böök, Olof
Casal-Dujat, Lucia
Stathis, Georgios
Fork, Thomas - Abstract:
- Background: Diseases of the bowel are not always displayed on conventional abdominal computed tomography (CT). The studied oral contrast agent aims to improve this. Purpose: To investigate whether the use of a novel oral contrast for abdominal CT enables the same diagnostic advantages as seen in magnetic resonance imaging (MRI). Material and Methods: Twenty-five consented volunteers drank up to 1400 mL of a stable, drinkable foam. Comments on acceptance and side effects were noted immediately and 24 h later. Foam palatability was documented through interviews, and distribution in the small bowel by Hounsfield units from the CT software. The CT results were compared with age- and sex-matched controls, pretreated according to routine. A non-enhanced abdominal CT protocol of lowest possible radiation dose was used. External referees evaluated all data obtained. Results: Foam was considered odd to swallow, and fullness was reported by all volunteers after 950 mL. Five had difficulties in drinking the last 320 mL and two abstained from it. All adverse symptoms were mild. The distribution in the small bowel was on par with standard agents. Foam density revealed stability with intraluminal values of around –550 HU from stomach to terminal ileum, satisfying the requirement of a great bowel lumen-to-wall contrast. External reviewers re-evaluated all our data, and one predicted the foam to offer a potential for improved diagnostics. Conclusion: A CT true-negative bowel filling agentBackground: Diseases of the bowel are not always displayed on conventional abdominal computed tomography (CT). The studied oral contrast agent aims to improve this. Purpose: To investigate whether the use of a novel oral contrast for abdominal CT enables the same diagnostic advantages as seen in magnetic resonance imaging (MRI). Material and Methods: Twenty-five consented volunteers drank up to 1400 mL of a stable, drinkable foam. Comments on acceptance and side effects were noted immediately and 24 h later. Foam palatability was documented through interviews, and distribution in the small bowel by Hounsfield units from the CT software. The CT results were compared with age- and sex-matched controls, pretreated according to routine. A non-enhanced abdominal CT protocol of lowest possible radiation dose was used. External referees evaluated all data obtained. Results: Foam was considered odd to swallow, and fullness was reported by all volunteers after 950 mL. Five had difficulties in drinking the last 320 mL and two abstained from it. All adverse symptoms were mild. The distribution in the small bowel was on par with standard agents. Foam density revealed stability with intraluminal values of around –550 HU from stomach to terminal ileum, satisfying the requirement of a great bowel lumen-to-wall contrast. External reviewers re-evaluated all our data, and one predicted the foam to offer a potential for improved diagnostics. Conclusion: A CT true-negative bowel filling agent was formulated, with high acceptance, few side effects, and a potential to mimic T1-weighted MRI images. … (more)
- Is Part Of:
- Acta radiologica. Volume 62:Number 12(2021)
- Journal:
- Acta radiologica
- Issue:
- Volume 62:Number 12(2021)
- Issue Display:
- Volume 62, Issue 12 (2021)
- Year:
- 2021
- Volume:
- 62
- Issue:
- 12
- Issue Sort Value:
- 2021-0062-0012-0000
- Page Start:
- 1559
- Page End:
- 1566
- Publication Date:
- 2021-12
- Subjects:
- Imaging -- computed tomography -- small bowel -- oral contrast -- negative Hounsfield Units
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185120973620 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18398.xml