A Mock Circulation Loop for In Vitro Hemodynamic Evaluation of Aorta: Application in Aortic Dissection. (February 2022)
- Record Type:
- Journal Article
- Title:
- A Mock Circulation Loop for In Vitro Hemodynamic Evaluation of Aorta: Application in Aortic Dissection. (February 2022)
- Main Title:
- A Mock Circulation Loop for In Vitro Hemodynamic Evaluation of Aorta: Application in Aortic Dissection
- Authors:
- Chen, Duanduan
Liang, Shichao
Li, Zhenfeng
Mei, Yuqian
Dong, Huiwu
Ma, Yihao
Zhao, Jing
Xu, Shangdong
Zheng, Jun
Xiong, Jiang - Abstract:
- Purpose: Aortic dissection (AD) is a catastrophic disease with complex hemodynamic conditions, however, understandings regarding its perfusion characteristics were not sufficient. In this study, a mock circulation loop (MCL) that integrated the Windkessel element and patient-specific silicone aortic phantoms was proposed to reproduce the aortic flow environment in vitro. Materials and Methods: Patient-specific normal and dissected aortic phantoms with 12 branching vessels were established and embedded into this MCL. Velocities for aortic branches based on 20 healthy volunteers were regarded as the standardized data for flow division. By altering boundary conditions, the proposed MCL could mimic normal resting and left-sided heart failure (LHF) conditions. Flow rates and pressure status of the aortic branches could be quantified by separate sensors. Results: In normal resting condition, the simulated heart rate and systemic flow rate were 60 bpm and 4.85 L/minute, respectively. For the LHF condition, the systolic and diastolic blood pressures were 75.94±0.77 mmHg and 57.65±0.35 mmHg, respectively. By tuning the vascular compliance and peripheral resistance, the flow distribution ratio (FDR) of each aortic branch was validated by the standardized data in the normal aortic phantom (mean difference 2.4%±1.70%). By comparing between the normal and dissected aortic models under resting condition, our results indicated that the AD model presented higher systolic (117.82±0.60 vsPurpose: Aortic dissection (AD) is a catastrophic disease with complex hemodynamic conditions, however, understandings regarding its perfusion characteristics were not sufficient. In this study, a mock circulation loop (MCL) that integrated the Windkessel element and patient-specific silicone aortic phantoms was proposed to reproduce the aortic flow environment in vitro. Materials and Methods: Patient-specific normal and dissected aortic phantoms with 12 branching vessels were established and embedded into this MCL. Velocities for aortic branches based on 20 healthy volunteers were regarded as the standardized data for flow division. By altering boundary conditions, the proposed MCL could mimic normal resting and left-sided heart failure (LHF) conditions. Flow rates and pressure status of the aortic branches could be quantified by separate sensors. Results: In normal resting condition, the simulated heart rate and systemic flow rate were 60 bpm and 4.85 L/minute, respectively. For the LHF condition, the systolic and diastolic blood pressures were 75.94±0.77 mmHg and 57.65±0.35 mmHg, respectively. By tuning the vascular compliance and peripheral resistance, the flow distribution ratio (FDR) of each aortic branch was validated by the standardized data in the normal aortic phantom (mean difference 2.4%±1.70%). By comparing between the normal and dissected aortic models under resting condition, our results indicated that the AD model presented higher systolic (117.82±0.60 vs 108.75±2.26 mmHg) and diastolic (72.38±0.58 vs 70.46±2.33 mmHg) pressures, the time-average velocity in the true lumen (TL; 36.95 cm/s) was higher than that in the false lumen (FL; 22.95 cm/s), and the blood transport direction between the TL and FL varied in different re-entries. Conclusions: The proposed MCL could be applied as a research tool for in vitro hemodynamic analysis of the aorta diseases under various physical conditions. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 29:Number 1(2022)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 29:Number 1(2022)
- Issue Display:
- Volume 29, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 29
- Issue:
- 1
- Issue Sort Value:
- 2022-0029-0001-0000
- Page Start:
- 132
- Page End:
- 142
- Publication Date:
- 2022-02
- Subjects:
- aorta -- aortic dissection -- mock circulation loop -- hemodynamics -- 3D printing
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/15266028211034863 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18386.xml