Impact of skull-to-brain conductivity ratio for high resolution EEG source localization. (4th August 2021)
- Record Type:
- Journal Article
- Title:
- Impact of skull-to-brain conductivity ratio for high resolution EEG source localization. (4th August 2021)
- Main Title:
- Impact of skull-to-brain conductivity ratio for high resolution EEG source localization
- Authors:
- Demoulin, Grégoire
Pruvost-Robieux, Estelle
Marchi, Angela
Ramdani, Céline
Badier, Jean-Michel
Bartolomei, Fabrice
Gavaret, Martine - Abstract:
- Abstract: Objective . To measure the impact of skull-to-brain conductivity ratios on interictal spikes source localizations, using high resolution EEG (HR EEG). In previous studies, two ratios were mainly employed: 1/80 and 1/40. Consequences of the employed ratios on source localization results are poorly studied. Methods . Twenty patients with drug-resistant epilepsy were studied using HR EEG (sixty-four scalp electrodes). For each patient, three-layers realistic head models based on individual MRI were elaborated using boundary element model. For each interictal spike, source localization was performed six times, using six skull-to-brain conductivity ratios (1/80, 1/50, 1/40, 1/30, 1/20 and 1/10), exploring all the spectrum of values reported in the literature. We then measured distances between the different sources obtained and between the sources and the anterior commissure (in order to estimate sources depth). Results . We measured a mean distance of 5.3 mm (sd: 3 mm) between the sources obtained with 1/40 versus 1/80 ratio. This distance increased when the discrepancy between the two evaluated ratios increased. We measured a mean distance of 14.2 mm (sd: 4.9 mm) between sources obtained with 1/10 ratio versus 1/80 ratio. Sources localized using 1/40 ratio were 4.3 mm closer to the anterior commissure than sources localized using 1/80 ratio. Significance . Skull-to-brain conductivity ratio is an often-neglected parameter in source localization studies. The differentAbstract: Objective . To measure the impact of skull-to-brain conductivity ratios on interictal spikes source localizations, using high resolution EEG (HR EEG). In previous studies, two ratios were mainly employed: 1/80 and 1/40. Consequences of the employed ratios on source localization results are poorly studied. Methods . Twenty patients with drug-resistant epilepsy were studied using HR EEG (sixty-four scalp electrodes). For each patient, three-layers realistic head models based on individual MRI were elaborated using boundary element model. For each interictal spike, source localization was performed six times, using six skull-to-brain conductivity ratios (1/80, 1/50, 1/40, 1/30, 1/20 and 1/10), exploring all the spectrum of values reported in the literature. We then measured distances between the different sources obtained and between the sources and the anterior commissure (in order to estimate sources depth). Results . We measured a mean distance of 5.3 mm (sd: 3 mm) between the sources obtained with 1/40 versus 1/80 ratio. This distance increased when the discrepancy between the two evaluated ratios increased. We measured a mean distance of 14.2 mm (sd: 4.9 mm) between sources obtained with 1/10 ratio versus 1/80 ratio. Sources localized using 1/40 ratio were 4.3 mm closer to the anterior commissure than sources localized using 1/80 ratio. Significance . Skull-to-brain conductivity ratio is an often-neglected parameter in source localization studies. The different ratios mainly used in the litterature (1/80 and 1/40) lead to significant differences in source localizations. These variations mainly occur in source depth. A more accurate estimation of skull-to-brain conductivity is needed to increase source localization accuracy. Abbreviations . ECD: equivalent current dipole; EIT: electric impedance tomography, HR EEG: High resolution Electroencephalography, IIS: Inter ictal spikes, MEG: Magnetoencephalography, MRI: Magnetic resonance imaging, mS/m: milli-Siemens/m, S/m: Siemens/m, SD: Standard deviation. … (more)
- Is Part Of:
- Biomedical physics & engineering express. Volume 7:Number 5(2021)
- Journal:
- Biomedical physics & engineering express
- Issue:
- Volume 7:Number 5(2021)
- Issue Display:
- Volume 7, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 7
- Issue:
- 5
- Issue Sort Value:
- 2021-0007-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08-04
- Subjects:
- high resolution EEG -- source localization -- skull conductivity -- conductivity ratio -- boundary element model
Medical physics -- Periodicals
Biophysics -- Periodicals
Biomedical engineering -- Periodicals
Medical sciences -- Periodicals
610.153 - Journal URLs:
- http://iopscience.iop.org/2057-1976/ ↗
http://www.iop.org/ ↗ - DOI:
- 10.1088/2057-1976/ac177f ↗
- Languages:
- English
- ISSNs:
- 2057-1976
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18394.xml