Can Ambu self-inflating bag and Neopuff infant resuscitator provide adequate and safe manual inflations for infants up to 10 kg weight?. Issue 4 (23rd December 2016)
- Record Type:
- Journal Article
- Title:
- Can Ambu self-inflating bag and Neopuff infant resuscitator provide adequate and safe manual inflations for infants up to 10 kg weight?. Issue 4 (23rd December 2016)
- Main Title:
- Can Ambu self-inflating bag and Neopuff infant resuscitator provide adequate and safe manual inflations for infants up to 10 kg weight?
- Authors:
- Tracy, Mark
Maheshwari, Rajesh
Shah, Dharmesh
Hinder, Murray - Abstract:
- Abstract : Background: Manual resuscitation devices for infants and newborns must be able to provide adequate ventilation in a safe and consistent manner across a wide range of patient sizes (0.5–10 kg) and differing clinical states. There are little comparative data assessing biomechanical performance of common infant manual resuscitation devices across the manufacturers' recommended operating weight ranges. We aimed to compare performance of the Ambu self-inflating bag (SIB) with the Neopuff T-piece resuscitator in three resuscitation models. Methods: Five experienced clinicians delivered targeted ventilation to three lung models differing in compliance, delivery pressures and inflation rates; Preterm (0.5 mL/cmH2 O, 25/5 cmH2 O, 60 per minute), Term (3 mL/cmH2 O, 30/5 cmH2 O, 40 per minute) and Infant (9 mL/cmH2 O, 35/5 cmH2 O, 30 per minute). The Neopuff was examined with three gas inflow rates (5 litres per minute (LPM), 10 LPM and 15 LPM) and the Ambu with no gas inflow. Results: 3309 inflations were collected and analysed with analysis of variance for repeated measures. The Neopuff was unable to reach set peak inflation pressures and exhibited seriously elevated positive end expiratory pressure (PEEP) with all inflow gas rates (p<0.001) in this infant model. The Ambu SIB accurately delivered targeted pressures in all three models. Conclusions: The Ambu SIB was able to accurately deliver targeted pressures across all three models from preterm to infant. The NeopuffAbstract : Background: Manual resuscitation devices for infants and newborns must be able to provide adequate ventilation in a safe and consistent manner across a wide range of patient sizes (0.5–10 kg) and differing clinical states. There are little comparative data assessing biomechanical performance of common infant manual resuscitation devices across the manufacturers' recommended operating weight ranges. We aimed to compare performance of the Ambu self-inflating bag (SIB) with the Neopuff T-piece resuscitator in three resuscitation models. Methods: Five experienced clinicians delivered targeted ventilation to three lung models differing in compliance, delivery pressures and inflation rates; Preterm (0.5 mL/cmH2 O, 25/5 cmH2 O, 60 per minute), Term (3 mL/cmH2 O, 30/5 cmH2 O, 40 per minute) and Infant (9 mL/cmH2 O, 35/5 cmH2 O, 30 per minute). The Neopuff was examined with three gas inflow rates (5 litres per minute (LPM), 10 LPM and 15 LPM) and the Ambu with no gas inflow. Results: 3309 inflations were collected and analysed with analysis of variance for repeated measures. The Neopuff was unable to reach set peak inflation pressures and exhibited seriously elevated positive end expiratory pressure (PEEP) with all inflow gas rates (p<0.001) in this infant model. The Ambu SIB accurately delivered targeted pressures in all three models. Conclusions: The Ambu SIB was able to accurately deliver targeted pressures across all three models from preterm to infant. The Neopuff infant resuscitator was unable to deliver the targeted pressures in the infant model developing clinically significant levels of inadvertent PEEP which may pose risk during infant resuscitation. … (more)
- Is Part Of:
- Archives of disease in childhood. Volume 102:Issue 4(2017)
- Journal:
- Archives of disease in childhood
- Issue:
- Volume 102:Issue 4(2017)
- Issue Display:
- Volume 102, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 102
- Issue:
- 4
- Issue Sort Value:
- 2017-0102-0004-0000
- Page Start:
- F333
- Page End:
- F338
- Publication Date:
- 2016-12-23
- Subjects:
- Resuscitation -- Infant -- Self Inflating Bag -- T-Piece Resuscitator -- Neopuff
Infants -- Diseases -- Periodicals
Newborn infants -- Diseases -- Periodicals
Fetus -- Diseases -- Periodicals
618.920105 - Journal URLs:
- http://fn.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/archdischild-2016-311830 ↗
- Languages:
- English
- ISSNs:
- 1359-2998
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18398.xml