A randomised controlled trial of flow driver and bubble continuous positive airway pressure in preterm infants in a resource-limited setting. Issue 1 (13th August 2015)
- Record Type:
- Journal Article
- Title:
- A randomised controlled trial of flow driver and bubble continuous positive airway pressure in preterm infants in a resource-limited setting. Issue 1 (13th August 2015)
- Main Title:
- A randomised controlled trial of flow driver and bubble continuous positive airway pressure in preterm infants in a resource-limited setting
- Authors:
- Mazmanyan, P
Mellor, K
Doré, C J
Modi, N - Abstract:
- Abstract : Objectives: The variable-flow flow driver (FD; EME) and continuous-flow bubble (Fisher-Paykel) continuous positive airway pressure (CPAP) systems are widely used. As these differ in cost and technical requirements, determining comparative efficacy is important particularly where resources are limited. Design: We performed a randomised, controlled, equivalence trial of CPAP systems. We specified the margin of equivalence as 2 days. We analysed binary variables by logistical regression adjusted for gestation, and log transformed continuous variables by multiple linear regression adjusted for gestation, sex and antenatal steroids. Setting: A neonatal unit with no blood gas analyser or surfactant availability and limited X-ray and laboratory facilities Patients: Neonates <37 weeks of gestation. Interventions: We provided CPAP at delivery followed by randomisation to FD or bubble (B). Outcomes: Primary outcome included total days receiving CPAP; secondary outcomes included days receiving CPAP, supplemental oxygen, ventilation, death, pneumothorax and nasal excoriation. Results: We randomised 125 infants (B 66, FD 59). Differences in infant outcomes on B and FD were not statistically significant. The median (range) for CPAP days for survivors was B 0.8 (0.04 to 17.5), FD 0.5 (0.04 to 5.3). B:FD (95% CI) ratios were CPAP days 1.3 (0.9 to 2.1), CPAP plus supplementary oxygen days 1.2 (0.7 to 1.9). B:FD (95% CI) ORs were death 2.3 (0.2 to 28), ventilation 2.1 (0.5 to 9),Abstract : Objectives: The variable-flow flow driver (FD; EME) and continuous-flow bubble (Fisher-Paykel) continuous positive airway pressure (CPAP) systems are widely used. As these differ in cost and technical requirements, determining comparative efficacy is important particularly where resources are limited. Design: We performed a randomised, controlled, equivalence trial of CPAP systems. We specified the margin of equivalence as 2 days. We analysed binary variables by logistical regression adjusted for gestation, and log transformed continuous variables by multiple linear regression adjusted for gestation, sex and antenatal steroids. Setting: A neonatal unit with no blood gas analyser or surfactant availability and limited X-ray and laboratory facilities Patients: Neonates <37 weeks of gestation. Interventions: We provided CPAP at delivery followed by randomisation to FD or bubble (B). Outcomes: Primary outcome included total days receiving CPAP; secondary outcomes included days receiving CPAP, supplemental oxygen, ventilation, death, pneumothorax and nasal excoriation. Results: We randomised 125 infants (B 66, FD 59). Differences in infant outcomes on B and FD were not statistically significant. The median (range) for CPAP days for survivors was B 0.8 (0.04 to 17.5), FD 0.5 (0.04 to 5.3). B:FD (95% CI) ratios were CPAP days 1.3 (0.9 to 2.1), CPAP plus supplementary oxygen days 1.2 (0.7 to 1.9). B:FD (95% CI) ORs were death 2.3 (0.2 to 28), ventilation 2.1 (0.5 to 9), nasal excoriation 1.2 (0.2 to 8) and pneumothorax 2.4 (0.2 to 26). Conclusions: In a resource-limited setting we found B CPAP equivalent to FD CPAP in the total number of days receiving CPAP within a margin of 2 days. Trial registration number: ISRCTN22578364. … (more)
- Is Part Of:
- Archives of disease in childhood. Volume 101:Issue 1(2016)
- Journal:
- Archives of disease in childhood
- Issue:
- Volume 101:Issue 1(2016)
- Issue Display:
- Volume 101, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 101
- Issue:
- 1
- Issue Sort Value:
- 2016-0101-0001-0000
- Page Start:
- 16
- Page End:
- 20
- Publication Date:
- 2015-08-13
- Subjects:
- Infant preterm -- Infant newborn -- continuous positive airway pressure -- ventilation -- low and middle income country
Infants -- Diseases -- Periodicals
Newborn infants -- Diseases -- Periodicals
Fetus -- Diseases -- Periodicals
618.920105 - Journal URLs:
- http://fn.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/archdischild-2015-308464 ↗
- Languages:
- English
- ISSNs:
- 1359-2998
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18386.xml