Brain-mimicking phantom for biomechanical validation of motion sensitive MR imaging techniques. (October 2021)
- Record Type:
- Journal Article
- Title:
- Brain-mimicking phantom for biomechanical validation of motion sensitive MR imaging techniques. (October 2021)
- Main Title:
- Brain-mimicking phantom for biomechanical validation of motion sensitive MR imaging techniques
- Authors:
- Ozkaya, E.
Triolo, E.R.
Rezayaraghi, F.
Abderezaei, J.
Meinhold, W.
Hong, K.
Alipour, A.
Kennedy, P.
Fleysher, L.
Ueda, J.
Balchandani, P.
Eriten, M.
Johnson, C.L.
Yang, Y.
Kurt, M. - Abstract:
- Abstract: Motion sensitive MR imaging techniques allow for the non-invasive evaluation of biological tissues by using different excitation schemes, including physiological/intrinsic motions caused by cardiac pulsation or respiration, and vibrations caused by an external actuator. The mechanical biomarkers extracted through these imaging techniques have been shown to hold diagnostic value for various neurological disorders and conditions. Amplified MRI (aMRI), a cardiac gated imaging technique, can help track and quantify low frequency intrinsic motion of the brain. As for high frequency actuation, the mechanical response of brain tissue can be measured by applying external high frequency actuation in combination with a motion sensitive MR imaging sequence called Magnetic Resonance Elastography (MRE). Due to the frequency-dependent behavior of brain mechanics, there is a need to develop brain phantom models that can mimic the broadband mechanical response of the brain in order to validate motion-sensitive MR imaging techniques. Here, we have designed a novel phantom test setup that enables both the low and high frequency responses of a brain-mimicking phantom to be captured, allowing for both aMRI and MRE imaging techniques to be applied on the same phantom model. This setup combines two different vibration sources: a pneumatic actuator, for low frequency/intrinsic motion (1 Hz) for use in aMRI, and a piezoelectric actuator for high frequency actuation (30–60 Hz) for use inAbstract: Motion sensitive MR imaging techniques allow for the non-invasive evaluation of biological tissues by using different excitation schemes, including physiological/intrinsic motions caused by cardiac pulsation or respiration, and vibrations caused by an external actuator. The mechanical biomarkers extracted through these imaging techniques have been shown to hold diagnostic value for various neurological disorders and conditions. Amplified MRI (aMRI), a cardiac gated imaging technique, can help track and quantify low frequency intrinsic motion of the brain. As for high frequency actuation, the mechanical response of brain tissue can be measured by applying external high frequency actuation in combination with a motion sensitive MR imaging sequence called Magnetic Resonance Elastography (MRE). Due to the frequency-dependent behavior of brain mechanics, there is a need to develop brain phantom models that can mimic the broadband mechanical response of the brain in order to validate motion-sensitive MR imaging techniques. Here, we have designed a novel phantom test setup that enables both the low and high frequency responses of a brain-mimicking phantom to be captured, allowing for both aMRI and MRE imaging techniques to be applied on the same phantom model. This setup combines two different vibration sources: a pneumatic actuator, for low frequency/intrinsic motion (1 Hz) for use in aMRI, and a piezoelectric actuator for high frequency actuation (30–60 Hz) for use in MRE. Our results show that in MRE experiments performed from 30 Hz through 60 Hz, propagating shear waves attenuate faster at higher driving frequencies, consistent with results in the literature. Furthermore, actuator coupling has a substantial effect on wave amplitude, with weaker coupling causing lower amplitude wave field images, specifically shown in the top-surface shear loading configuration. For intrinsic actuation, our results indicate that aMRI linearly amplifies motion up to at least an amplification factor of 9 for instances of both visible and sub-voxel motion, validated by varying power levels of pneumatic actuation (40%–80% power) under MR, and through video analysis outside the MRI scanner room. While this investigation used a homogeneous brain-mimicking phantom, our setup can be used to study the mechanics of non-homogeneous phantom configurations with bio-interfaces in the future. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 122(2021)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 122(2021)
- Issue Display:
- Volume 122, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 122
- Issue:
- 2021
- Issue Sort Value:
- 2021-0122-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10
- Subjects:
- Brain biomechanics -- Brain-mimicking phantom -- CINE imaging -- MR elastography
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2021.104680 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18378.xml