AB0396 Infliximab and Adalimumab Levels and Antidrug Antibodies Detection in Patients with Rheumatoid Arthritis (RA): an Interlaboratory Comparison Using A Commercial ELISA Assay. (10th June 2014)
- Record Type:
- Journal Article
- Title:
- AB0396 Infliximab and Adalimumab Levels and Antidrug Antibodies Detection in Patients with Rheumatoid Arthritis (RA): an Interlaboratory Comparison Using A Commercial ELISA Assay. (10th June 2014)
- Main Title:
- AB0396 Infliximab and Adalimumab Levels and Antidrug Antibodies Detection in Patients with Rheumatoid Arthritis (RA): an Interlaboratory Comparison Using A Commercial ELISA Assay
- Authors:
- Valor, L.
Hernández Flόrez, D.
de la Torre, I.
Llinares, F.
Rosas, J.
Yaque, J.
Naredo, E.
Gonzalez, C.
Lόpez-Longo, J.
Monteagudo, I.
Montoro, M.
Carreño Perez, L. - Abstract:
- Abstract : Background: The assessment of biological drug levels and immunogenicity might be essential in terms of a more effective and rational use of biological therapies and it is dependent upon the establishment of efficient standardized assays or a consensus that could allow a direct comparison of drug levels and anti-drug antibodies (ADA) data with clinical outcome. Objectives: To determine whether an enzyme-linked immunosorbent assay (ELISA) performed with two versions of a commercial kit to assess IFX and ADL levels and ADA yield similar results. Methods: The diagnostic capability of two ELISA versions [Promonitor® IFX R1 and R2 (V.1), Promonitor® IFX and Anti-IFX (V.2); Promonitor® ADL R1 and R2 (V.1), Promonitor® ADL and Anti-ADL (V.2) kits (Progenika Biopharma, Spain)] was evaluated in patients with RA treated either with infliximab (IFX; n=24) or adalimumab (ADL; n=24) by three different laboratories. The reliability was determined using the Cohen's Kappa coefficient (K), the Pearson's r, the intraclass correlation coefficient (ICC) and the Lin's concordance correlation coefficient (CCC). The Bland-Altman plots of differences between V.1 and V.2 were drawn to compare values of each assay. Results: The qualitative discordant results for IFX levels V.1 were 9/24 samples (K= good) and 2/23 V.2 (K= very good), for ADL levels V.1 were 7/24 (K= moderate) and for V.2 were 0/24 (K= very good). For IFX-ADA were 0/24 in V.1 and V.2 (K= excellent), while for ADL-ADA wereAbstract : Background: The assessment of biological drug levels and immunogenicity might be essential in terms of a more effective and rational use of biological therapies and it is dependent upon the establishment of efficient standardized assays or a consensus that could allow a direct comparison of drug levels and anti-drug antibodies (ADA) data with clinical outcome. Objectives: To determine whether an enzyme-linked immunosorbent assay (ELISA) performed with two versions of a commercial kit to assess IFX and ADL levels and ADA yield similar results. Methods: The diagnostic capability of two ELISA versions [Promonitor® IFX R1 and R2 (V.1), Promonitor® IFX and Anti-IFX (V.2); Promonitor® ADL R1 and R2 (V.1), Promonitor® ADL and Anti-ADL (V.2) kits (Progenika Biopharma, Spain)] was evaluated in patients with RA treated either with infliximab (IFX; n=24) or adalimumab (ADL; n=24) by three different laboratories. The reliability was determined using the Cohen's Kappa coefficient (K), the Pearson's r, the intraclass correlation coefficient (ICC) and the Lin's concordance correlation coefficient (CCC). The Bland-Altman plots of differences between V.1 and V.2 were drawn to compare values of each assay. Results: The qualitative discordant results for IFX levels V.1 were 9/24 samples (K= good) and 2/23 V.2 (K= very good), for ADL levels V.1 were 7/24 (K= moderate) and for V.2 were 0/24 (K= very good). For IFX-ADA were 0/24 in V.1 and V.2 (K= excellent), while for ADL-ADA were 1/24 in V.1 and 4/24 in V.2 (K= from very good to good). The quantitative agreement is shown in table 1, we found a good linear association using the Pearson's r, the ICC was questionable to excellent for both versions in IFX and ADL levels. The CCC results were poor in all determinations. Bland-Altman plots for both, IFX and ADL levels demonstrate the differences between both versions (Fig. 1 and 2, respectively). Conclusions: We observed a better agreement in the qualitative than in the quantitative results in both, for IFX and ADL levels and for IFX-ADA and ADL-ADA. We have found a good linear association (Pearson's r) but a low agreement (K, ICC and CCC) comparing results for V.1 and V.2. Further interlaboratory investigations are necessary to improve results and determine their possible clinical application. Disclosure of Interest: L. Valor: None declared, D. Hernández Flόrez: None declared, I. de la Torre: None declared, F. Llinares: None declared, J. Rosas: None declared, J. Yaque: None declared, E. Naredo Grant/research support: UCB and MSD, Consultant for: Abbvie, Roche Farma, Bristol-Myers Squibb, Pfizer, UCB, General Electric Healthcare, and Esaote, C. Gonzalez: None declared, J. Lόpez-Longo: None declared, I. Monteagudo Consultant for: Abbvie, Roche Farma, Bristol-Myers Squibb, Pfizer, UCB, General Electric Healthcare, MSD and Esaote, M. Montoro: None declared, L. Carreño Perez: None declared DOI: 10.1136/annrheumdis-2014-eular.3290 … (more)
- Is Part Of:
- Annals of the rheumatic diseases. Volume 73:Supplement 2(2014)
- Journal:
- Annals of the rheumatic diseases
- Issue:
- Volume 73:Supplement 2(2014)
- Issue Display:
- Volume 73, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 73
- Issue:
- 2
- Issue Sort Value:
- 2014-0073-0002-0000
- Page Start:
- 937
- Page End:
- 937
- Publication Date:
- 2014-06-10
- Subjects:
- Rheumatism -- Periodicals
616.723005 - Journal URLs:
- http://ard.bmjjournals.com/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=149&action=archive ↗
http://www.bmj.com/archive ↗
http://gateway.ovid.com/server3/ovidweb.cgi?T=JS&MODE=ovid&D=ovft&PAGE=titles&SEARCH=annals+of+the+rheumatic+diseases.tj&NEWS=N ↗ - DOI:
- 10.1136/annrheumdis-2014-eular.3290 ↗
- Languages:
- English
- ISSNs:
- 0003-4967
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18363.xml