Comparison of scanning laser ophthalmoscopy and high-definition optical coherence tomography measurements of optic disc parameters. Issue 4 (9th February 2012)
- Record Type:
- Journal Article
- Title:
- Comparison of scanning laser ophthalmoscopy and high-definition optical coherence tomography measurements of optic disc parameters. Issue 4 (9th February 2012)
- Main Title:
- Comparison of scanning laser ophthalmoscopy and high-definition optical coherence tomography measurements of optic disc parameters
- Authors:
- Foo, Li-Lian
Perera, Shamira A
Cheung, Carol Y
Allen, John C
Zheng, Yingfeng
Loon, Seng-Chee
Wong, Tien Y
Aung, Tin - Abstract:
- Abstract : Objective: To investigate the agreement between scanning laser ophthalmoscopy (Heidelberg retinal tomograph 3; HRT-3) and high-definition optical coherence tomography (HD–OCT) for measurements of optic nerve head (ONH) parameters. Methods: As part of a population-based cross-sectional study, 913 consecutive Chinese subjects aged 40 years and older underwent HRT-3 and HD–OCT imaging of the ONH after pupillary dilation. Limits of agreement (LOA) derived from Bland–Altman analysis were calculated for ONH measurements. Results: The mean age (±SD) of study participants was 54.2±7.2 years and 52.0% were men. The two instruments showed no difference in mean optic disc area measurements (1.98±0.37 for HD–OCT vs 1.98±0.39 mm for HRT-3, p=0.95). HD–OCT showed smaller rim area (1.29±0.24 vs 1.46±0.27 mm, p<0.001), but bigger cup-related parameters (p<0.001 for all) than HRT-3. The highest correlations between the instruments were observed for cup volume (r 2 =0.74, p<0.001) and disc area (r 2 =0.62, p<0.001). The correlations for cup-to-disc ratio (CDR), vertical CDR and rim area were lower (r 2 =0.59, 0.48 and 0.24, respectively, p<0.001 for all). The Bland–Altman plots demonstrated significant proportional bias for differences in all ONH parameters (p<0.01 for all), with LOA greater for disc-related parameters (0.98–1.0) than cup-related parameters (0.26–0.50). Conclusions: There are substantial disagreements between HRT-3 and HD–OCT in ONH measurements. Although opticAbstract : Objective: To investigate the agreement between scanning laser ophthalmoscopy (Heidelberg retinal tomograph 3; HRT-3) and high-definition optical coherence tomography (HD–OCT) for measurements of optic nerve head (ONH) parameters. Methods: As part of a population-based cross-sectional study, 913 consecutive Chinese subjects aged 40 years and older underwent HRT-3 and HD–OCT imaging of the ONH after pupillary dilation. Limits of agreement (LOA) derived from Bland–Altman analysis were calculated for ONH measurements. Results: The mean age (±SD) of study participants was 54.2±7.2 years and 52.0% were men. The two instruments showed no difference in mean optic disc area measurements (1.98±0.37 for HD–OCT vs 1.98±0.39 mm for HRT-3, p=0.95). HD–OCT showed smaller rim area (1.29±0.24 vs 1.46±0.27 mm, p<0.001), but bigger cup-related parameters (p<0.001 for all) than HRT-3. The highest correlations between the instruments were observed for cup volume (r 2 =0.74, p<0.001) and disc area (r 2 =0.62, p<0.001). The correlations for cup-to-disc ratio (CDR), vertical CDR and rim area were lower (r 2 =0.59, 0.48 and 0.24, respectively, p<0.001 for all). The Bland–Altman plots demonstrated significant proportional bias for differences in all ONH parameters (p<0.01 for all), with LOA greater for disc-related parameters (0.98–1.0) than cup-related parameters (0.26–0.50). Conclusions: There are substantial disagreements between HRT-3 and HD–OCT in ONH measurements. Although optic disc area measurements were similar, HD–OCT underestimates the rim area and overestimates cup parameters compared with HRT-3. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 96:Issue 4(2012)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 96:Issue 4(2012)
- Issue Display:
- Volume 96, Issue 4 (2012)
- Year:
- 2012
- Volume:
- 96
- Issue:
- 4
- Issue Sort Value:
- 2012-0096-0004-0000
- Page Start:
- 576
- Page End:
- 580
- Publication Date:
- 2012-02-09
- Subjects:
- Anterior chamber -- clinical trial -- diagnostic tests/investigation -- epidemiology -- genetics -- glaucoma -- imaging -- intraocular pressure -- lens and zonules -- neovascularisation -- pharmacology -- public health -- retina -- treatment surgery
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2011-300835 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18351.xml