How does EuroSCORE II perform in UK cardiac surgery; an analysis of 23 740 patients from the Society for Cardiothoracic Surgery in Great Britain and Ireland National Database. Issue 21 (21st August 2012)
- Record Type:
- Journal Article
- Title:
- How does EuroSCORE II perform in UK cardiac surgery; an analysis of 23 740 patients from the Society for Cardiothoracic Surgery in Great Britain and Ireland National Database. Issue 21 (21st August 2012)
- Main Title:
- How does EuroSCORE II perform in UK cardiac surgery; an analysis of 23 740 patients from the Society for Cardiothoracic Surgery in Great Britain and Ireland National Database
- Authors:
- Grant, Stuart William
Hickey, Graeme Lee
Dimarakis, Ioannis
Trivedi, Uday
Bryan, Alan
Treasure, Tom
Cooper, Graham
Pagano, Domenico
Buchan, Iain
Bridgewater, Ben - Abstract:
- Abstract : Objective: The original EuroSCORE models are poorly calibrated for predicting mortality in contemporary cardiac surgery. EuroSCORE II has been proposed as a new risk model. The objective of this study was to assess the performance of EuroSCORE II in UK cardiac surgery. Design: A cross-sectional analysis of prospectively collected multi-centre clinical audit data, from the Society for Cardiothoracic Surgery in Great Britain and Ireland Database. Setting: All NHS hospitals, and some UK private hospitals performing adult cardiac surgery. Patients: 23 740 procedures at 41 hospitals between July 2010 and March 2011. Main outcome measures: The main outcome measure was in-hospital mortality. Model calibration (Hosmer–Lemeshow test, calibration plot) and discrimination (area under receiver operating characteristic curve) were assessed in the overall cohort and clinically defined sub-groups. Results: The mean age at procedure was 67.1 years (SD 11.8) and 27.7% were women. The overall mortality was 3.1% with a EuroSCORE II predicted mortality of 3.4%. Calibration was good overall but the model failed the Hosmer–Lemeshow test (p=0.003) mainly due to over-prediction in the highest and lowest-risk patients. Calibration was poor for isolated coronary artery bypass graft surgery (Hosmer–Lemeshow, p<0.001). The model had good discrimination overall (area under receiver operating characteristic curve 0.808, 95% CI 0.793 to 0.824) and in all clinical sub-groups analysed.Abstract : Objective: The original EuroSCORE models are poorly calibrated for predicting mortality in contemporary cardiac surgery. EuroSCORE II has been proposed as a new risk model. The objective of this study was to assess the performance of EuroSCORE II in UK cardiac surgery. Design: A cross-sectional analysis of prospectively collected multi-centre clinical audit data, from the Society for Cardiothoracic Surgery in Great Britain and Ireland Database. Setting: All NHS hospitals, and some UK private hospitals performing adult cardiac surgery. Patients: 23 740 procedures at 41 hospitals between July 2010 and March 2011. Main outcome measures: The main outcome measure was in-hospital mortality. Model calibration (Hosmer–Lemeshow test, calibration plot) and discrimination (area under receiver operating characteristic curve) were assessed in the overall cohort and clinically defined sub-groups. Results: The mean age at procedure was 67.1 years (SD 11.8) and 27.7% were women. The overall mortality was 3.1% with a EuroSCORE II predicted mortality of 3.4%. Calibration was good overall but the model failed the Hosmer–Lemeshow test (p=0.003) mainly due to over-prediction in the highest and lowest-risk patients. Calibration was poor for isolated coronary artery bypass graft surgery (Hosmer–Lemeshow, p<0.001). The model had good discrimination overall (area under receiver operating characteristic curve 0.808, 95% CI 0.793 to 0.824) and in all clinical sub-groups analysed. Conclusions: EuroSCORE II performs well overall in the UK and is an acceptable contemporary generic cardiac surgery risk model. However, the model is poorly calibrated for isolated coronary artery bypass graft surgery and in both the highest and lowest risk patients. Regular revalidation of EuroSCORE II will be needed to identify calibration drift or clinical inconsistencies, which commonly emerge in clinical prediction models. … (more)
- Is Part Of:
- Heart. Volume 98:Issue 21(2012)
- Journal:
- Heart
- Issue:
- Volume 98:Issue 21(2012)
- Issue Display:
- Volume 98, Issue 21 (2012)
- Year:
- 2012
- Volume:
- 98
- Issue:
- 21
- Issue Sort Value:
- 2012-0098-0021-0000
- Page Start:
- 1568
- Page End:
- 1572
- Publication Date:
- 2012-08-21
- Subjects:
- Risk assessment -- EuroSCORE II -- cardiac surgery -- mortality -- coronary artery bypass grafting -- aortic valve replacement
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/heartjnl-2012-302483 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18344.xml