The effect of continuous positive airway pressure usage on sleepiness in obstructive sleep apnoea: real effects or expectation of benefit?. Issue 10 (26th May 2012)
- Record Type:
- Journal Article
- Title:
- The effect of continuous positive airway pressure usage on sleepiness in obstructive sleep apnoea: real effects or expectation of benefit?. Issue 10 (26th May 2012)
- Main Title:
- The effect of continuous positive airway pressure usage on sleepiness in obstructive sleep apnoea: real effects or expectation of benefit?
- Authors:
- Crawford, Megan R
Bartlett, Delwyn J
Coughlin, Steven R
Phillips, Craig L
Neill, Alister M
Espie, Colin A
Dungan, George C
Wilding, John P H
Calverley, Peter M A
Grunstein, Ronald R
Marshall, Nathaniel S - Abstract:
- Abstract : Rationale: Placebo responses are complex psychobiological phenomena and often involve patient expectation of benefit. With continuous positive airway pressure (CPAP) treatment of obstructive sleep apnoea, greater hours of CPAP use are associated with reduced sleepiness. However, these open-label studies have not controlled for patient expectation of benefit derived from their knowledge of hours of device use. Objectives: To investigate the relative effectiveness of the use of real or placebo CPAP on daytime sleepiness. Methods: Patient-level meta-analysis combining data on sleepiness measured by the Epworth Sleepiness Scale from three randomised placebo-controlled crossover trials. Mixed model analysis of variance was used to quantify the effects of real versus placebo device treatment, usage, their interaction and regression to the mean. Measurements and main results: Duration of real and placebo CPAP use was correlated within patients (r=0.53, p<0.001). High use of real CPAP reduced sleepiness more than high use of placebo (difference 3.0 points; 95% CI 1.7 to 4.3, p<0.001) and more than low use of real CPAP (difference 3.3; 95% CI 1.9 to 4.7, p<0.0001). High use of placebo was superior to low use of placebo (difference 1.5; 95% CI 0.1 to 2.8, p=0.03). Twenty-nine per cent of the effect of high usage of CPAP (4.2 points; 95% CI 3.3 to 5.1) was explained by the expectation of benefit effect associated with high use of placebo (1.2 points ; 95% CI 0.2 to 2.3).Abstract : Rationale: Placebo responses are complex psychobiological phenomena and often involve patient expectation of benefit. With continuous positive airway pressure (CPAP) treatment of obstructive sleep apnoea, greater hours of CPAP use are associated with reduced sleepiness. However, these open-label studies have not controlled for patient expectation of benefit derived from their knowledge of hours of device use. Objectives: To investigate the relative effectiveness of the use of real or placebo CPAP on daytime sleepiness. Methods: Patient-level meta-analysis combining data on sleepiness measured by the Epworth Sleepiness Scale from three randomised placebo-controlled crossover trials. Mixed model analysis of variance was used to quantify the effects of real versus placebo device treatment, usage, their interaction and regression to the mean. Measurements and main results: Duration of real and placebo CPAP use was correlated within patients (r=0.53, p<0.001). High use of real CPAP reduced sleepiness more than high use of placebo (difference 3.0 points; 95% CI 1.7 to 4.3, p<0.001) and more than low use of real CPAP (difference 3.3; 95% CI 1.9 to 4.7, p<0.0001). High use of placebo was superior to low use of placebo (difference 1.5; 95% CI 0.1 to 2.8, p=0.03). Twenty-nine per cent of the effect of high usage of CPAP (4.2 points; 95% CI 3.3 to 5.1) was explained by the expectation of benefit effect associated with high use of placebo (1.2 points ; 95% CI 0.2 to 2.3). Conclusions: A clinically significant proportion of the effectiveness of high CPAP use in reducing sleepiness is probably caused by patient expectation of benefit. … (more)
- Is Part Of:
- Thorax. Volume 67:Issue 10(2012)
- Journal:
- Thorax
- Issue:
- Volume 67:Issue 10(2012)
- Issue Display:
- Volume 67, Issue 10 (2012)
- Year:
- 2012
- Volume:
- 67
- Issue:
- 10
- Issue Sort Value:
- 2012-0067-0010-0000
- Page Start:
- 920
- Page End:
- 924
- Publication Date:
- 2012-05-26
- Subjects:
- Adherence -- compliance -- placebo effects -- dose–response -- psychology -- respiratory measurement -- sleep apnoea -- clinical epidemiology -- oxidative stress -- assisted ventilation -- pneumonia -- rare lung diseases -- non-invasive ventilation -- COPD exacerbations -- emphysema -- asthma -- ambulatory oxygen therapy -- COPD pharmacology -- long term oxygen therapy -- lung physiology -- respiratory muscles -- short burst oxygen therapy
Chest -- Diseases -- Periodicals
Thorax
Chest -- Diseases
Periodicals
Periodicals
617.54 - Journal URLs:
- http://thorax.bmjjournals.com/contents-by-date.0.shtml ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/thoraxjnl-2012-201622 ↗
- Languages:
- English
- ISSNs:
- 0040-6376
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18339.xml