Re-evaluation of the left atrial to aortic root ratio as a marker of patent ductus arteriosus. Issue 2 (March 1994)
- Record Type:
- Journal Article
- Title:
- Re-evaluation of the left atrial to aortic root ratio as a marker of patent ductus arteriosus. Issue 2 (March 1994)
- Main Title:
- Re-evaluation of the left atrial to aortic root ratio as a marker of patent ductus arteriosus.
- Authors:
- Iyer, P
Evans, N - Abstract:
- Abstract : The aim of this study was to re-examine the accuracy of the left atrial aortic root ratio (LA:Ao) as a marker of significant patent ductus arteriosus (PDA) in the preterm infant by comparison with direct Doppler echocardiographic assessment. Fifty six infants (< 1500 g) had 463 serial echocardiograms. Firstly the LA:Ao was measured, then the duct was imaged and classified as wide open, restricting, or closed according to two dimensional and Doppler criteria. Probability analysis was performed to test the ability of the LA:Ao to discriminate between a wide open PDA and a restricting or closed duct. Mean LA:Ao was 1.17 and 1.21 when the duct was respectively closed or restricting compared with 1.61 when wide open. Using a LA:Ao of 1.5 as a cut off gives a sensitivity of 79% and specificity of 95% and increases the accuracy over the recommended levels of 1.3 and 1.4. With this cut off there were 20/94 false negatives, these were associated with scans on day 1 and large interatrial shunts. The sensitivity of the LA:Ao increased to 88% if only scans performed after day 1 were analysed. For diagnosing a PDA after day 1, the positive likelihood ratio of an LA:Ao of 1.5 or more was 17.5, and the negative likelihood ratio of an LA:Ao < 1.5 was 0.13. The LA:Ao is still a useful tool in the diagnosis of PDA. It is a simple method which needs less skill and resources than direct PDA imaging and is feasible on neonatal units without direct access to echocardiographicAbstract : The aim of this study was to re-examine the accuracy of the left atrial aortic root ratio (LA:Ao) as a marker of significant patent ductus arteriosus (PDA) in the preterm infant by comparison with direct Doppler echocardiographic assessment. Fifty six infants (< 1500 g) had 463 serial echocardiograms. Firstly the LA:Ao was measured, then the duct was imaged and classified as wide open, restricting, or closed according to two dimensional and Doppler criteria. Probability analysis was performed to test the ability of the LA:Ao to discriminate between a wide open PDA and a restricting or closed duct. Mean LA:Ao was 1.17 and 1.21 when the duct was respectively closed or restricting compared with 1.61 when wide open. Using a LA:Ao of 1.5 as a cut off gives a sensitivity of 79% and specificity of 95% and increases the accuracy over the recommended levels of 1.3 and 1.4. With this cut off there were 20/94 false negatives, these were associated with scans on day 1 and large interatrial shunts. The sensitivity of the LA:Ao increased to 88% if only scans performed after day 1 were analysed. For diagnosing a PDA after day 1, the positive likelihood ratio of an LA:Ao of 1.5 or more was 17.5, and the negative likelihood ratio of an LA:Ao < 1.5 was 0.13. The LA:Ao is still a useful tool in the diagnosis of PDA. It is a simple method which needs less skill and resources than direct PDA imaging and is feasible on neonatal units without direct access to echocardiographic expertise. Its use on the first postnatal day is not recommended. … (more)
- Is Part Of:
- Archives of disease in childhood. Volume 70:Issue 2(1994)
- Journal:
- Archives of disease in childhood
- Issue:
- Volume 70:Issue 2(1994)
- Issue Display:
- Volume 70, Issue 2 (1994)
- Year:
- 1994
- Volume:
- 70
- Issue:
- 2
- Issue Sort Value:
- 1994-0070-0002-0000
- Page Start:
- F112
- Page End:
- F117
- Publication Date:
- 1994-03
- Subjects:
- Infants -- Diseases -- Periodicals
Newborn infants -- Diseases -- Periodicals
Fetus -- Diseases -- Periodicals
618.920105 - Journal URLs:
- http://fn.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/fn.70.2.F112 ↗
- Languages:
- English
- ISSNs:
- 1359-2998
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18341.xml