Routine monitoring of visual outcome of cataract surgery. Part 1: Development of an instrument. Issue 1 (21st December 2004)
- Record Type:
- Journal Article
- Title:
- Routine monitoring of visual outcome of cataract surgery. Part 1: Development of an instrument. Issue 1 (21st December 2004)
- Main Title:
- Routine monitoring of visual outcome of cataract surgery. Part 1: Development of an instrument
- Authors:
- Limburg, H
Foster, A
Gilbert, C
Johnson, G J
Kyndt, M - Abstract:
- Abstract : Aim: To develop a system for routine monitoring of visual outcome after cataract surgery. Methods: Staff from eight eye centres in Asia and Africa defined the data collection form and report formats to be used for monitoring visual outcome after cataract surgery. Several operational research questions were raised and methods developed to address them. The system was field tested for 6 months and the operational studies undertaken. The system was finalised based upon the experience gained. Findings: Two different systems for data collection were developed: a manual paper tally system and a computer system (cataract surgery record forms (CSRF)). Both systems report on operative complications; the proportion with good outcome (can see 6/18) and poor outcome (cannot see 6/60); and causes of poor outcome. Data are collected at discharge and at specified time intervals at follow up. Both systems were well accepted. Conclusion: The major problem in field testing was data entry errors in centres using the computerised system. Routine monitoring of cataract outcome should be used by individual surgeons or centres to follow trends in their own results over time, and not to compare surgeons, in an atmosphere of trust and support. Visual acuity at discharge, which can readily be collected on all patients, can be used providing it is appreciated that the final results will be much better. Rapid feedback of results can enhance the consciousness of the eye surgeons to causes ofAbstract : Aim: To develop a system for routine monitoring of visual outcome after cataract surgery. Methods: Staff from eight eye centres in Asia and Africa defined the data collection form and report formats to be used for monitoring visual outcome after cataract surgery. Several operational research questions were raised and methods developed to address them. The system was field tested for 6 months and the operational studies undertaken. The system was finalised based upon the experience gained. Findings: Two different systems for data collection were developed: a manual paper tally system and a computer system (cataract surgery record forms (CSRF)). Both systems report on operative complications; the proportion with good outcome (can see 6/18) and poor outcome (cannot see 6/60); and causes of poor outcome. Data are collected at discharge and at specified time intervals at follow up. Both systems were well accepted. Conclusion: The major problem in field testing was data entry errors in centres using the computerised system. Routine monitoring of cataract outcome should be used by individual surgeons or centres to follow trends in their own results over time, and not to compare surgeons, in an atmosphere of trust and support. Visual acuity at discharge, which can readily be collected on all patients, can be used providing it is appreciated that the final results will be much better. Rapid feedback of results can enhance the consciousness of the eye surgeons to causes of poor outcome. Accuracy in data entry and an efficient flow of record forms are essential. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 89:Issue 1(2005)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 89:Issue 1(2005)
- Issue Display:
- Volume 89, Issue 1 (2005)
- Year:
- 2005
- Volume:
- 89
- Issue:
- 1
- Issue Sort Value:
- 2005-0089-0001-0000
- Page Start:
- 45
- Page End:
- 49
- Publication Date:
- 2004-12-21
- Subjects:
- CCSRF, computerised cataract surgical record form -- IOL, intraocular lens -- MCSRF, manual cataract surgical record form
cataract -- outcome -- monitoring systems -- software
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjo.2004.045351 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18331.xml