The prague C & M criteria for grading barrett's oesophagus: a live endoscopy evaluation of observer agreement. (13th March 2011)
- Record Type:
- Journal Article
- Title:
- The prague C & M criteria for grading barrett's oesophagus: a live endoscopy evaluation of observer agreement. (13th March 2011)
- Main Title:
- The prague C & M criteria for grading barrett's oesophagus: a live endoscopy evaluation of observer agreement
- Authors:
- Shutt, J
Chan, D
Boger, C
Patel, P - Abstract:
- Abstract : Introduction: To validate the Prague C and M criteria for the endoscopic diagnosis and grading of Barrett's oesophagus (BO) in a real-time clinical setting between two experienced endoscopists in a University teaching hospital in the UK. Methods: Forty consecutive cases with BO were studied. A nurse endoscopist applied the Prague C and M criteria to record the Circumferential and Maximal extent of BO on push and pull endoscopy, this was repeated on pull endoscopy by a doctor (blinded to the initial assessment, with the nurse endoscopist not present). Landmark measurements were recorded by an independent observer. Intra- and inter-rater agreement regarding the length of C and M was evaluated by the correlation coefficient and Bland-Altman analysis. Results: The Pearson correlation coefficients (r) for nurse pull against push endoscopy were 0.89 for C and 0.87 for M (p<0.001), and for doctor against nurse were 0.76 for C and 0.80 for M (p<0.001). Comparing pull against push endoscopy, the exact rates of agreement were 15/40 and 12/40 for C and M respectively, differing by 1 cm in 30/40 and 27/40, and by 2 cm in 30/40 and 36/40 respectively. There were 5 and 4 cases with differences of 3 or 4 cm for C and M respectively. Comparing doctor against nurse, the exact rates of agreement were 8/40 and 6/40 for C and M respectively, differing by 1 cm in 20/40 and 21/40, and by 2 cm in 30/40 and 29/40 respectively. There were 9 and 11 cases with differences of 3 or 4 cm for CAbstract : Introduction: To validate the Prague C and M criteria for the endoscopic diagnosis and grading of Barrett's oesophagus (BO) in a real-time clinical setting between two experienced endoscopists in a University teaching hospital in the UK. Methods: Forty consecutive cases with BO were studied. A nurse endoscopist applied the Prague C and M criteria to record the Circumferential and Maximal extent of BO on push and pull endoscopy, this was repeated on pull endoscopy by a doctor (blinded to the initial assessment, with the nurse endoscopist not present). Landmark measurements were recorded by an independent observer. Intra- and inter-rater agreement regarding the length of C and M was evaluated by the correlation coefficient and Bland-Altman analysis. Results: The Pearson correlation coefficients (r) for nurse pull against push endoscopy were 0.89 for C and 0.87 for M (p<0.001), and for doctor against nurse were 0.76 for C and 0.80 for M (p<0.001). Comparing pull against push endoscopy, the exact rates of agreement were 15/40 and 12/40 for C and M respectively, differing by 1 cm in 30/40 and 27/40, and by 2 cm in 30/40 and 36/40 respectively. There were 5 and 4 cases with differences of 3 or 4 cm for C and M respectively. Comparing doctor against nurse, the exact rates of agreement were 8/40 and 6/40 for C and M respectively, differing by 1 cm in 20/40 and 21/40, and by 2 cm in 30/40 and 29/40 respectively. There were 9 and 11 cases with differences of 3 or 4 cm for C and M respectively, and 1 case where C differed by 5 cm. From the Bland-Altman analysis, the mean difference in C between pull and push endoscopy was 0.33 cm (95% CI −0.22 to 2.00), with limits of agreement from −2.59 to 3.24 cm. For M, the mean difference between pull and push endoscopy was 0.63 cm (95% CI 0.07 to 2.03), with limits of agreement from −2.33 to 3.58 cm. The mean difference in C between doctor and nurse was −0.03 cm (95% CI −0.82 to 2.94), with limits of agreement from −4.31 to 4.26 cm. For M the mean difference between doctor and nurse was −0.33 cm (95% CI −1.09 to 2.81), with limits of agreement from −4.41 to 3.76 cm. Conclusion: There was good agreement for interobserver C and M values of BO at live endoscopy, but with clinically significant limits of agreement that must be considered in any studies that use the Prague criteria, especially in trials that report a reduction in the length of BO as an end point. In this real-time clinical setting, patient movement and retching, compounded by the lack of 1 cm markings on the endoscope may well have contributed to this reduced degree of agreement. … (more)
- Is Part Of:
- Gut. Volume 60:(2011)Supplement 1
- Journal:
- Gut
- Issue:
- Volume 60:(2011)Supplement 1
- Issue Display:
- Volume 60, Issue 1 (2011)
- Year:
- 2011
- Volume:
- 60
- Issue:
- 1
- Issue Sort Value:
- 2011-0060-0001-0000
- Page Start:
- A178
- Page End:
- A178
- Publication Date:
- 2011-03-13
- Subjects:
- Barrett's oesophagus -- Endoscopic Classification -- Prague C and M
Gastroenterology -- Periodicals
616.33 - Journal URLs:
- http://gut.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/gut.2011.239301.378 ↗
- Languages:
- English
- ISSNs:
- 0017-5749
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18328.xml