Measuring the quality of screening colonoscopy: moving on from adenoma detection rate. (13th March 2011)
- Record Type:
- Journal Article
- Title:
- Measuring the quality of screening colonoscopy: moving on from adenoma detection rate. (13th March 2011)
- Main Title:
- Measuring the quality of screening colonoscopy: moving on from adenoma detection rate
- Authors:
- Lee, T J W
Nickerson, C
Rees, C J
Rutter, M D - Abstract:
- Abstract : Introduction: Adenoma detection rate (ADR) is the most widely used metric to assess quality of colonoscopy. Studies have shown ADR to correlate with other measures of colonoscopic performance such as withdrawal time, caecal intubation rate and longer term outcomes such as interval cancer rate. ADR is calculated by dividing the number of procedures in which one or more adenomas are detected by the total number of procedures. It has an inherent limitation in that it does not measure the total number of adenomas detected. The ethos of screening colonoscopy, in addition to detecting cancer, is to detect and remove all adenomas. This abstract examines other measures of adenoma detection in the context of the NHS Bowel Cancer Screening Programme (BCSP). Methods: Data from all screening colonoscopies in the BCSP performed between August 2006 and August 2009 were analysed. The following measures of adenoma detection were calculated for each colonoscopist who had performed ≤50 procedures: ADR, MAP (mean adenomas per patient−total number of adenomas detected/ number of procedures), MAP+ (mean adenomas per positive procedure−total number of adenomas detected/ number of procedures in which one or more adenoma were detected). Correlation was assessed using Pearson's correlation coefficient. This abstract examines other measures of adenoma detection in the context of the NHS BCSP. Results: 31 088 procedures performed by 148 colonoscopists (mean 210 procedures per colonoscopist)Abstract : Introduction: Adenoma detection rate (ADR) is the most widely used metric to assess quality of colonoscopy. Studies have shown ADR to correlate with other measures of colonoscopic performance such as withdrawal time, caecal intubation rate and longer term outcomes such as interval cancer rate. ADR is calculated by dividing the number of procedures in which one or more adenomas are detected by the total number of procedures. It has an inherent limitation in that it does not measure the total number of adenomas detected. The ethos of screening colonoscopy, in addition to detecting cancer, is to detect and remove all adenomas. This abstract examines other measures of adenoma detection in the context of the NHS Bowel Cancer Screening Programme (BCSP). Methods: Data from all screening colonoscopies in the BCSP performed between August 2006 and August 2009 were analysed. The following measures of adenoma detection were calculated for each colonoscopist who had performed ≤50 procedures: ADR, MAP (mean adenomas per patient−total number of adenomas detected/ number of procedures), MAP+ (mean adenomas per positive procedure−total number of adenomas detected/ number of procedures in which one or more adenoma were detected). Correlation was assessed using Pearson's correlation coefficient. This abstract examines other measures of adenoma detection in the context of the NHS BCSP. Results: 31 088 procedures performed by 148 colonoscopists (mean 210 procedures per colonoscopist) were analysed. The mean, range, SD and correlation with ADR of each of the measures of adenoma detection are shown in table 1 . 46.5% of patients have one or more adenomas, of these 53% have only one adenoma. For this reason, MAP and ADR correlate closely. However, MAP displays much greater variation than ADR. MAP+ demonstrated less variation and correlates less well with ADR. Conclusion: MAP reflects the aim of screening colonoscopy to detect and remove all adenomas. MAP may be a more sensitive measure of colonoscopic performance but prospective studies are required to confirm this. MAP+ is a less useful measure of adenoma detection in isolation. It is largely dependent on the ADR but may still be high despite a low ADR. It may be useful as an adjunct to ADR or MAP in colonoscopists with evidence of high colonoscopic performance (ADR greater than the mean of the population). In this group, MAP+ identifies a group of colonoscopists attaining very high adenoma detection. … (more)
- Is Part Of:
- Gut. Volume 60:(2011)Supplement 1
- Journal:
- Gut
- Issue:
- Volume 60:(2011)Supplement 1
- Issue Display:
- Volume 60, Issue 1 (2011)
- Year:
- 2011
- Volume:
- 60
- Issue:
- 1
- Issue Sort Value:
- 2011-0060-0001-0000
- Page Start:
- A46
- Page End:
- A46
- Publication Date:
- 2011-03-13
- Subjects:
- adenoma -- colonoscopy -- colorectal cancer -- screening
Gastroenterology -- Periodicals
616.33 - Journal URLs:
- http://gut.bmjjournals.com ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/gut.2011.239301.90 ↗
- Languages:
- English
- ISSNs:
- 0017-5749
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18326.xml