Short and Mid Term Outcomes of Cryopreserved Abdominal Aortic Allografts Used as a Substitute for Infected Prosthetic Grafts in 200 Patients. (July 2021)
- Record Type:
- Journal Article
- Title:
- Short and Mid Term Outcomes of Cryopreserved Abdominal Aortic Allografts Used as a Substitute for Infected Prosthetic Grafts in 200 Patients. (July 2021)
- Main Title:
- Short and Mid Term Outcomes of Cryopreserved Abdominal Aortic Allografts Used as a Substitute for Infected Prosthetic Grafts in 200 Patients
- Authors:
- Couture, Thibault
Gaudric, Julien
Du Montcel, Sophie Tezenas
Jayet, Jérémie
Verscheure, Dorian
Davaine, Jean Michel
Jarraya, Mohamed
Chiche, Laurent
Koskas, Fabien - Abstract:
- Abstract : Objective: To investigate the use of cryopreserved arterial allografts (CAA) as a substitute for infected infrarenal aortic prostheses, and its outcomes. Methods: A single centre retrospective study of consecutive patients receiving an abdominal aortic CAA after removal of an infected graft was conducted between January 1997 and December 2013. The primary outcome was the rate of allograft related revision surgery. Secondary outcomes were the 30 day mortality rate, survival, primary patency, limb salvage, and infection recurrence. Allograft ruptures secondary to infection and risk factors for allograft failure were also investigated. Results: Two hundred patients (mean age 64.2 ± 9.4 years) were included. In 56 (28%) cases, infection was related to an enteric fistula. The mean follow up duration was 4.1 years. The 30 day mortality rate was 11%. Early revision surgery was needed in 59 patients (29.5%). Among them, 15 (7.5%) were allograft related and led to the death of three patients (1.5%), corresponding to a 7.5% 30 day allograft related revision surgery rate. During the first six months, 17 (8.5%) patients experienced 21 events with complete or partial rupture (pseudo-aneurysm) of the allograft responsible for five (2.5%) deaths, corresponding to a re-infection rate of 8.5%. The multivariable analysis showed that diabetes and pseudo-aneurysm of the native aorta on presentation were predictive factors for short term allograft rupture. After six months, 25 (12.5%)Abstract : Objective: To investigate the use of cryopreserved arterial allografts (CAA) as a substitute for infected infrarenal aortic prostheses, and its outcomes. Methods: A single centre retrospective study of consecutive patients receiving an abdominal aortic CAA after removal of an infected graft was conducted between January 1997 and December 2013. The primary outcome was the rate of allograft related revision surgery. Secondary outcomes were the 30 day mortality rate, survival, primary patency, limb salvage, and infection recurrence. Allograft ruptures secondary to infection and risk factors for allograft failure were also investigated. Results: Two hundred patients (mean age 64.2 ± 9.4 years) were included. In 56 (28%) cases, infection was related to an enteric fistula. The mean follow up duration was 4.1 years. The 30 day mortality rate was 11%. Early revision surgery was needed in 59 patients (29.5%). Among them, 15 (7.5%) were allograft related and led to the death of three patients (1.5%), corresponding to a 7.5% 30 day allograft related revision surgery rate. During the first six months, 17 (8.5%) patients experienced 21 events with complete or partial rupture (pseudo-aneurysm) of the allograft responsible for five (2.5%) deaths, corresponding to a re-infection rate of 8.5%. The multivariable analysis showed that diabetes and pseudo-aneurysm of the native aorta on presentation were predictive factors for short term allograft rupture. After six months, 25 (12.5%) patients experienced long term allograft complications (rupture, n = 2, 1%; pseudo-aneurysm, n = 6, 3%; aneurysm, n = 2, 1%; thrombosis, n = 11, 5.5%; stenosis, n = 4, 2%;) requiring revision surgery resulting in one death. The five year rates of survival, allograft related revision surgery, limb salvage, primary patency, and infection recurrence were 56%, 30%, 89%, 80%, and 12%, respectively. Conclusion: CAAs provide acceptable results to treat aortic graft infection with few early graft related fatal complications. Long term allograft related complications are quite common but are associated with low mortality and amputation rates. … (more)
- Is Part Of:
- European journal of vascular and endovascular surgery. Volume 62:Number 1(2021)
- Journal:
- European journal of vascular and endovascular surgery
- Issue:
- Volume 62:Number 1(2021)
- Issue Display:
- Volume 62, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 62
- Issue:
- 1
- Issue Sort Value:
- 2021-0062-0001-0000
- Page Start:
- 89
- Page End:
- 97
- Publication Date:
- 2021-07
- Subjects:
- Abdominal aorta -- Allografts -- Prosthesis-related infection
Blood-vessels -- Endoscopic surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
Blood-vessels -- Endoscopic surgery
Blood-vessels -- Surgery
Endoscopy
Electronic journals
Periodicals
Electronic journals
617.413005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1078-5884;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/ejvs/ ↗
http://www.harcourt-international.com/journals/ejvx/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10785884 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10785884 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejvs.2021.02.036 ↗
- Languages:
- English
- ISSNs:
- 1078-5884
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.747280
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18300.xml