Development of a high resolution MRI intracranial atherosclerosis imaging phantom. (9th March 2017)
- Record Type:
- Journal Article
- Title:
- Development of a high resolution MRI intracranial atherosclerosis imaging phantom. (9th March 2017)
- Main Title:
- Development of a high resolution MRI intracranial atherosclerosis imaging phantom
- Authors:
- Chueh, Ju-Yu
van der Marel, Kajo
Gounis, Matthew J
LeMatty, Todd
Brown, Truman R
Ansari, Sameer A
Carroll, Timothy J
Buck, Amanda K
Zhou, Xiaohong Joe
Chatterjee, A Rano
King, Robert M
Mao, Hui
Zheng, Shaokuan
Brooks, Olivia W
Rappleye, Jeff W
Swartz, Richard H
Feldmann, Edward
Turan, Tanya N - Abstract:
- Abstract : Background and purpose: Currently, there is neither a standard protocol for vessel wall MR imaging of intracranial atherosclerotic disease (ICAD) nor a gold standard phantom to compare MR sequences. In this study, a plaque phantom is developed and characterized that provides a platform for establishing a uniform imaging approach for ICAD. Materials and methods: A patient specific injection mold was 3D printed to construct a geometrically accurate ICAD phantom. Polyvinyl alcohol hydrogel was infused into the core shell mold to form the stenotic artery. The ICAD phantom incorporated materials mimicking a stenotic vessel and plaque components, including fibrous cap and lipid core. Two phantoms were scanned using high resolution cone beam CT and compared with four different 3 T MRI systems across eight different sites over a period of 18 months. Inter-phantom variability was assessed by lumen dimensions and contrast to noise ratio (CNR). Results: Quantitative evaluation of the minimum lumen radius in the stenosis showed that the radius was on average 0.80 mm (95% CI 0.77 to 0.82 mm) in model 1 and 0.77 mm (95% CI 0.74 to 0.81 mm) in model 2. The highest CNRs were observed for comparisons between lipid and vessel wall. To evaluate manufacturing reproducibility, the CNR variability between the two models had an average absolute difference of 4.31 (95% CI 3.82 to 5.78). Variation in CNR between the images from the same scanner separated by 7 months was 2.5–6.2, showingAbstract : Background and purpose: Currently, there is neither a standard protocol for vessel wall MR imaging of intracranial atherosclerotic disease (ICAD) nor a gold standard phantom to compare MR sequences. In this study, a plaque phantom is developed and characterized that provides a platform for establishing a uniform imaging approach for ICAD. Materials and methods: A patient specific injection mold was 3D printed to construct a geometrically accurate ICAD phantom. Polyvinyl alcohol hydrogel was infused into the core shell mold to form the stenotic artery. The ICAD phantom incorporated materials mimicking a stenotic vessel and plaque components, including fibrous cap and lipid core. Two phantoms were scanned using high resolution cone beam CT and compared with four different 3 T MRI systems across eight different sites over a period of 18 months. Inter-phantom variability was assessed by lumen dimensions and contrast to noise ratio (CNR). Results: Quantitative evaluation of the minimum lumen radius in the stenosis showed that the radius was on average 0.80 mm (95% CI 0.77 to 0.82 mm) in model 1 and 0.77 mm (95% CI 0.74 to 0.81 mm) in model 2. The highest CNRs were observed for comparisons between lipid and vessel wall. To evaluate manufacturing reproducibility, the CNR variability between the two models had an average absolute difference of 4.31 (95% CI 3.82 to 5.78). Variation in CNR between the images from the same scanner separated by 7 months was 2.5–6.2, showing reproducible phantom durability. Conclusions: A plaque phantom composed of a stenotic vessel wall and plaque components was successfully constructed for multicenter high resolution MRI standardization. … (more)
- Is Part Of:
- Journal of neurointerventional surgery. Volume 10:Number 2(2018)
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 10:Number 2(2018)
- Issue Display:
- Volume 10, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 10
- Issue:
- 2
- Issue Sort Value:
- 2018-0010-0002-0000
- Page Start:
- 143
- Page End:
- 149
- Publication Date:
- 2017-03-09
- Subjects:
- Atherosclerosis -- MRI -- Stenosis -- Vessel Wall
Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2016-012974 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18301.xml