Assessing the efficacy, safety and utility of 6-month day-and-night automated closed-loop insulin delivery under free-living conditions compared with insulin pump therapy in children and adolescents with type 1 diabetes: an open-label, multicentre, multinational, single-period, randomised, parallel group study protocol. Issue 6 (3rd June 2019)
- Record Type:
- Journal Article
- Title:
- Assessing the efficacy, safety and utility of 6-month day-and-night automated closed-loop insulin delivery under free-living conditions compared with insulin pump therapy in children and adolescents with type 1 diabetes: an open-label, multicentre, multinational, single-period, randomised, parallel group study protocol. Issue 6 (3rd June 2019)
- Main Title:
- Assessing the efficacy, safety and utility of 6-month day-and-night automated closed-loop insulin delivery under free-living conditions compared with insulin pump therapy in children and adolescents with type 1 diabetes: an open-label, multicentre, multinational, single-period, randomised, parallel group study protocol
- Authors:
- Musolino, Gianluca
Allen, Janet M
Hartnell, Sara
Wilinska, Malgorzata E
Tauschmann, Martin
Boughton, Charlotte
Campbell, Fiona
Denvir, Louise
Trevelyan, Nicola
Wadwa, Paul
DiMeglio, Linda
Buckingham, Bruce A
Weinzimer, Stuart
Acerini, Carlo L
Hood, Korey
Fox, Steven
Kollman, Craig
Sibayan, Judy
Borgman, Sarah
Cheng, Peiyao
Hovorka, Roman - Abstract:
- Abstract : Introduction: Closed-loop systems titrate insulin based on sensor glucose levels, providing novel means to reduce the risk of hypoglycaemia while improving glycaemic control. We will assess effectiveness of 6-month day-and-night closed-loop insulin delivery compared with usual care (conventional or sensor-augmented pump therapy) in children and adolescents with type 1 diabetes. Methods and analysis: The trial adopts an open-label, multicentre, multinational (UK and USA), randomised, single-period, parallel design. Participants (n=130) are children and adolescents (aged ≥6 and <19 years) with type 1 diabetes for at least 1 year, and insulin pump use for at least 3 months with suboptimal glycaemic control (glycated haemoglobin ≥58 mmol/mol (7.5%) and ≤86 mmol/mol (10%)). After a 2–3 week run-in period, participants will be randomised to 6-month use of hybrid closed-loop insulin delivery, or to usual care. Analyses will be conducted on an intention-to-treat basis. The primary outcome is glycated haemoglobin at 6 months. Other key endpoints include time in the target glucose range (3.9–10 mmol/L, 70–180 mg/dL), mean sensor glucose and time spent above and below target. Secondary outcomes include SD and coefficient of variation of sensor glucose levels, time with sensor glucose levels <3.5 mmol/L (63 mg/dL) and <3.0 mmol/L (54 mg/dL), area under the curve of glucose <3.5 mmol/L (63 mg/dL), time with glucose levels >16.7 mmol/L (300 mg/dL), area under the curve ofAbstract : Introduction: Closed-loop systems titrate insulin based on sensor glucose levels, providing novel means to reduce the risk of hypoglycaemia while improving glycaemic control. We will assess effectiveness of 6-month day-and-night closed-loop insulin delivery compared with usual care (conventional or sensor-augmented pump therapy) in children and adolescents with type 1 diabetes. Methods and analysis: The trial adopts an open-label, multicentre, multinational (UK and USA), randomised, single-period, parallel design. Participants (n=130) are children and adolescents (aged ≥6 and <19 years) with type 1 diabetes for at least 1 year, and insulin pump use for at least 3 months with suboptimal glycaemic control (glycated haemoglobin ≥58 mmol/mol (7.5%) and ≤86 mmol/mol (10%)). After a 2–3 week run-in period, participants will be randomised to 6-month use of hybrid closed-loop insulin delivery, or to usual care. Analyses will be conducted on an intention-to-treat basis. The primary outcome is glycated haemoglobin at 6 months. Other key endpoints include time in the target glucose range (3.9–10 mmol/L, 70–180 mg/dL), mean sensor glucose and time spent above and below target. Secondary outcomes include SD and coefficient of variation of sensor glucose levels, time with sensor glucose levels <3.5 mmol/L (63 mg/dL) and <3.0 mmol/L (54 mg/dL), area under the curve of glucose <3.5 mmol/L (63 mg/dL), time with glucose levels >16.7 mmol/L (300 mg/dL), area under the curve of glucose >10.0 mmol/L (180 mg/dL), total, basal and bolus insulin dose, body mass index z-score and blood pressure. Cognitive, emotional and behavioural characteristics of participants and caregivers and their responses to the closed-loop and clinical trial will be assessed. An incremental cost-effectiveness ratio for closed-loop will be estimated. Ethics and dissemination: Cambridge South Research Ethics Committee and Jaeb Center for Health Research Institutional Review Office approved the study. The findings will be disseminated by peer-review publications and conference presentations. Trial registration number: NCT02925299 ; Pre-results. … (more)
- Is Part Of:
- BMJ open. Volume 9:Issue 6(2019)
- Journal:
- BMJ open
- Issue:
- Volume 9:Issue 6(2019)
- Issue Display:
- Volume 9, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 9
- Issue:
- 6
- Issue Sort Value:
- 2019-0009-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-06-03
- Subjects:
- type 1 diabetes -- closed-loop -- artificial pancreas
Medicine -- Research -- Periodicals
610.72 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bmjopen.bmj.com/ ↗ - DOI:
- 10.1136/bmjopen-2018-027856 ↗
- Languages:
- English
- ISSNs:
- 2044-6055
- Deposit Type:
- Legaldeposit