Effect of phacoemulsification on facility of outflow. Issue 11 (13th April 2018)
- Record Type:
- Journal Article
- Title:
- Effect of phacoemulsification on facility of outflow. Issue 11 (13th April 2018)
- Main Title:
- Effect of phacoemulsification on facility of outflow
- Authors:
- Alaghband, Pouya
Beltran-Agulló, Laura
Galvis, Elizabeth Angela
Overby, Darryl R
Lim, Kin Sheng - Abstract:
- Abstract : Purpose: Phacoemulsification has been shown to reduce intraocular pressure (IOP). The mechanism of action is thought to be via increased trabecular outflow facility. However, studies on the relationship between phacoemulsification and outflow facility have been inconsistent. This study intended to examine the change in electronic Schiotz tonographic outflow facility (TOF) and IOP measurements following phacoemulsification. Methods: Patients who were due to undergo a standard clear corneal incision phacoemulsification with intraocular lens (IOL) implantation, at St Thomas' Hospital, were invited to participate in this study. IOP was measured using Goldmann's applanation tonometer, and TOF was measured by electronic Schiotz tonography at baseline and at 3, 6 and 12 months postoperatively. Results: Forty-one patients were recruited. Tonography data for 27 patients were reliable and available at all time points. Eleven cases had primary open angle glaucoma and cataract, while 16 patients had cataract only. Mean IOP reduced at every time point postoperatively significantly compared with baseline. TOF improved significantly after cataract extraction at all time points (baseline of 0.14±0.06 vs 0.18±0.09 at 3 months, P=0.02 and 0.20±0.09 at 6 months, P=0.003, 0.17±0.07 µL/min mmHg at 12 months, P=0.04). Five contralateral eyes of patients with cataracts only who did not have any intraocular surgery during the follow-up period were used as comparison. Their IOP and TOFAbstract : Purpose: Phacoemulsification has been shown to reduce intraocular pressure (IOP). The mechanism of action is thought to be via increased trabecular outflow facility. However, studies on the relationship between phacoemulsification and outflow facility have been inconsistent. This study intended to examine the change in electronic Schiotz tonographic outflow facility (TOF) and IOP measurements following phacoemulsification. Methods: Patients who were due to undergo a standard clear corneal incision phacoemulsification with intraocular lens (IOL) implantation, at St Thomas' Hospital, were invited to participate in this study. IOP was measured using Goldmann's applanation tonometer, and TOF was measured by electronic Schiotz tonography at baseline and at 3, 6 and 12 months postoperatively. Results: Forty-one patients were recruited. Tonography data for 27 patients were reliable and available at all time points. Eleven cases had primary open angle glaucoma and cataract, while 16 patients had cataract only. Mean IOP reduced at every time point postoperatively significantly compared with baseline. TOF improved significantly after cataract extraction at all time points (baseline of 0.14±0.06 vs 0.18±0.09 at 3 months, P=0.02 and 0.20±0.09 at 6 months, P=0.003, 0.17±0.07 µL/min mmHg at 12 months, P=0.04). Five contralateral eyes of patients with cataracts only who did not have any intraocular surgery during the follow-up period were used as comparison. Their IOP and TOF did not change significantly at any postoperative visits. Conclusion: This is the first study using electronic Schiotz tonography with documented anterior chamber depth and gonioscopy after modern cataract surgery (CS) with phacoemulsification and IOL implantation. We demonstrated that phacoemulsification increases TOF and this fully accounts for the IOP reduction following CS. ISTCRN registration number: ISRCTN04247738 . … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 102:Issue 11(2018)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 102:Issue 11(2018)
- Issue Display:
- Volume 102, Issue 11 (2018)
- Year:
- 2018
- Volume:
- 102
- Issue:
- 11
- Issue Sort Value:
- 2018-0102-0011-0000
- Page Start:
- 1520
- Page End:
- 1526
- Publication Date:
- 2018-04-13
- Subjects:
- Phacoemulsification -- cataract surgery -- glaucoma -- outflow facility -- tonography
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2017-311548 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18288.xml