Ultrasound Machine Comparison: An Evaluation of Ergonomic Design, Data Management, Ease of Use, and Image Quality. Issue 4 (1st June 2009)
- Record Type:
- Journal Article
- Title:
- Ultrasound Machine Comparison: An Evaluation of Ergonomic Design, Data Management, Ease of Use, and Image Quality. Issue 4 (1st June 2009)
- Main Title:
- Ultrasound Machine Comparison: An Evaluation of Ergonomic Design, Data Management, Ease of Use, and Image Quality
- Authors:
- Wynd, Kimberly P.
Smith, Hugh M.
Jacob, Adam K.
Torsher, Laurence C.
Kopp, Sandra L.
Hebl, James R. - Abstract:
- Abstract : Background and Objectives: The use of ultrasound technology for vascular access and regional anesthesia is gaining widespread acceptance among anesthesia providers. As a result, many group practices and medical institutions are considering purchasing ultrasound equipment. Currently, comparative information regarding the ergonomic design, physical and adjustable features, data management, ease of use, cost, and image quality of various ultrasound machines is not available. The primary goal of this investigation was to develop an objective process of evaluating ultrasound equipment before purchase. The process of evaluation used in the current investigation may be used when comparing a variety of medical technologies. Methods: A randomized, side-by-side comparative evaluation of 7 different ultrasound machine models was performed. Sixteen resident physicians without prior ultrasound experience (inexperienced providers) completed a formal evaluation of each machine model after performing a standardized machine configuration and performance checklist. Inexperienced providers and 10 faculty members experienced in ultrasound-guided regional anesthesia evaluated the image quality of 2 standardized images acquired from each machine model. Results: Overall, evaluators rated questions on the machine evaluation form as "very good" or "outstanding" 70% or more of the time for all machine models. The largest, most complex ultrasound machine was rated as having the best imageAbstract : Background and Objectives: The use of ultrasound technology for vascular access and regional anesthesia is gaining widespread acceptance among anesthesia providers. As a result, many group practices and medical institutions are considering purchasing ultrasound equipment. Currently, comparative information regarding the ergonomic design, physical and adjustable features, data management, ease of use, cost, and image quality of various ultrasound machines is not available. The primary goal of this investigation was to develop an objective process of evaluating ultrasound equipment before purchase. The process of evaluation used in the current investigation may be used when comparing a variety of medical technologies. Methods: A randomized, side-by-side comparative evaluation of 7 different ultrasound machine models was performed. Sixteen resident physicians without prior ultrasound experience (inexperienced providers) completed a formal evaluation of each machine model after performing a standardized machine configuration and performance checklist. Inexperienced providers and 10 faculty members experienced in ultrasound-guided regional anesthesia evaluated the image quality of 2 standardized images acquired from each machine model. Results: Overall, evaluators rated questions on the machine evaluation form as "very good" or "outstanding" 70% or more of the time for all machine models. The largest, most complex ultrasound machine was rated as having the best image quality by both inexperienced and experienced providers. Ultrasound machine models with the simplest ergonomic design and user interface were rated highest by inexperienced study participants. Conclusions: Anesthesia providers considering an ultrasound equipment purchase should objectively evaluate machine models that have features most important to their own clinical practice. Ergonomic design, physical and adjustable features, data management, ease of use, image quality, and cost are important features to consider when evaluating an ultrasound machine. … (more)
- Is Part Of:
- Regional anesthesia and pain medicine. Volume 34:Issue 4(2009)
- Journal:
- Regional anesthesia and pain medicine
- Issue:
- Volume 34:Issue 4(2009)
- Issue Display:
- Volume 34, Issue 4 (2009)
- Year:
- 2009
- Volume:
- 34
- Issue:
- 4
- Issue Sort Value:
- 2009-0034-0004-0000
- Page Start:
- 349-356
- Page End:
- 349-356
- Publication Date:
- 2009-06-01
- Subjects:
- Conduction anesthesia -- Periodicals
Pain medicine -- Periodicals
617.964 - Journal URLs:
- http://www.rapm.org/ ↗
https://journals.lww.com/rapm/pages/default.aspx ↗
http://www.sciencedirect.com/science/journal/10987339 ↗
https://rapm.bmj.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/AAP.0b013e3181ac9e5b ↗
- Languages:
- English
- ISSNs:
- 1098-7339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7336.572210
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18278.xml